Bore Size: 50mm, Thread Type: N (NPT), Stroke: 25mm, Lock Position: R (Rod End Lock), Manual Release Type: L (Lock Type), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal
Magnet: Built-in, Mounting: Double Clevis, Bore Size: 20mm, Stroke: 25mm, Rod End Thread: Male Thread, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: Auto Switch Mounting Bracket
Magnet: Built-in, Mounting: Boss-cut/Rod Flange, Bore Size: 20mm, Stroke: 25mm, Rod End Thread: Male Thread, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: Auto Switch Mounting Bracket
Magnet: Built-in, Mounting: Boss-cut/Rod Trunnion, Bore Size: 40mm, Stroke: 25mm, Rod End Thread: Male Thread, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: Auto Switch Mounting Bracket
Magnet: Built-in Magnet, Mounting: Head Flange, Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 25mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Made to Order: -
Magnet: Built-in Magnet, Mounting: Double Clevis, Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 25mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Made to Order: -
Mounting: Through Hole, Bore Size: 32mm, Stroke: 25mm, Option: Standard (Rod End Female Thread), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: NPT, Auto Switches: M9B, Lead
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: Rc, Auto Switches: M9B, Lead
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: NPT, Auto Switches: M9B, Lead
: Built-in magnet, Port thread type: Rc, Auto Switches: M9B, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Type of Mount Support: Basic type, Rod Boot: None, Custom-made Specifications: None, Locking Direction: Bidirectional
Magnet: Built-in, Mounting: Front Flange, Bore Size: 20mm, Stroke: 25mm, Cushion: Rubber Bumper, Rod Boot: None, Lock Style: Rod Side Lock/Non-locking, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Rotary Actuator Vane Type CRB2 Series Size: 10, 15, 20, 30, 40 RoHS How to Order B S E 20 180 S Z CRB2 u Z L M9B CDRB2 B W 20 180 S With auto switch q r e !1 i o !
D-M9P(W/E)(V) D-M9B(W/E)(V) : The number marked on each lead wire color shows the pin number of pre-wired connector.
(C) Correction factor 1.25 1.11 1 0.90 0.63 2 to 25 30 32 35 40 2 to 25 30 32 35 40 45 2 to 25 30 32 35 40 2 to 25 30 32 35 40 2 to 25 30 32 35 40 Note) For the water-cooled type, the correction factor is determined to 1 in an ambient temperature range of 2 to 45C.
Series CY1S 6, 10, 15, 20, 25, 32, 40 How to Order CY1S 25 H 300 CDY1S 25 H 300 J79W With auto switch With switch rail Made to Order Refer to page 1195 for details.
Stroke (mm) Bore size 25 25 mm Port thread type 32 32 mm Bore size 25, 32, 40 50, 63 32, 50, 63 Type Rc NPT G Symbol Nil TN TF 40 40 mm 50 50 mm 63 63 mm Specifications 25 32 40 50 63 Bore size (mm) Fluid Air Proof pressure 1.05 MPa Maximum operating pressure 0.7 MPa Minimum operating pressure 0.18 MPa 10 to 60C (No freezing) Ambient and fluid temperature Piston speed (Max.)
bearing type High precision guide type CY B 1 3 Guide non-integrated type Guide integrated type 6 10 15 20 25 32 40 50 63 CY R 1 3 Magnetically coupled rodless cylinder 6 10 15 20 25 32 40 CY1S 6 10 15 20 25 32 40 CY1L 10 15 20 CY1H 25 (Single axis) 25 (Double axis) 32 Bilateral piping type Centralized piping type Auto switch Shock absorber The piping type for CY1R6 is bilateral piping only