Size: 16, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 150mm, Motor Option: None, Rod End Thread: Female, Mounting: Body Bottom Tapped, Actuator Cable: Standard Cable, Actuator Cable Length: 5m, Controller: LECP1, PNP, Programless Type, I/O Cable Length: 5m, Communication Plug Connector: None, Controller
Size: 10, Motor Size: Standard, Lead Screw Type, mm: K (LEP*6: 4; LEP*10: 5), Stroke: 25mm, Motor Cable Mounting Direction: Top Entry, Actuator Cable Type: S (Standard Cable), Actuator Cable Length, m: 5, Controller Type - LEC, JXC: 1P (LECP1, Programless Type, PNP), I/O Cable Length for LEC: 5 (5), Controller Mounting: D (DIN Rail Mounting, DIN Rail not Included)
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ROD TYPE, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, 7.16501 lb
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
Size: 40, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: A (LEY25, 12; LEY32/40, 16), Stroke: 300mm, Motor: w/o Lock, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: F (Rod Flange), Actuator Cable Length: 3m, Controller Type (LEC, JXC): C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC: w/o Cable, Controller Mounting
Size: 40, Motor Mounting Position: D (In-line), Motor Type: Step Motor (Servo/24 VDC), Lead Screw: A (LEY16: 10mm; LEY25: 12mm; LEY32/40: 16mm), Stroke: 50mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Male Rod End), Mounting: Ends Tapped (Standard), Actuator Cable Type: S (Standard Cable), Cable Length: 3 (3m), Controller/Driver Type: AP (LECPA, PNP, Pulse Input Type), I/O Cable
Size: 40, Motor Mounting Position: D (In-line), Motor Type: Step Motor (Servo/24 VDC), Lead Screw: A (LEY16: 10mm; LEY25: 12mm; LEY32/40: 16mm), Stroke: 30mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Male Rod End), Mounting: Ends Tapped (Standard), Actuator Cable Type: S (Standard Cable), Cable Length: 3 (3m), Controller/Driver Type: AP (LECPA, PNP, Pulse Input Type), I/O Cable
Size: 40, Motor Mounting Position: In-line, Motor Type: Step Motor (Servo/24 VDC), Lead Screw: LEY16: 10mm; LEY25: 12mm; LEY32/40: 16mm, Stroke: 50mm, Motor Option: w/Motor Cover, Rod End Thread: Male Rod End, Mounting: Ends Tapped (Standard), Actuator Cable Type: Standard Cable, Cable Length: 3m, Controller/Driver Type: LECPA, PNP, Pulse Input Type, I/O Cable Length: 3m, Protocol: -, Suffix
Size: 40, Motor Mounting Position: In-line, Motor Type: Step Motor (Servo/24 VDC), Lead Screw: LEY16: 10mm; LEY25: 12mm; LEY32/40: 16mm, Stroke: 30mm, Motor Option: w/Motor Cover, Rod End Thread: Male Rod End, Mounting: Ends Tapped (Standard), Actuator Cable Type: Standard Cable, Cable Length: 3m, Controller/Driver Type: LECPA, PNP, Pulse Input Type, I/O Cable Length: 3m, Protocol: -, Suffix
Size: 40, Motor Mounting: In-line Type, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 12; LEY32/40, 16, Stroke: 300mm, Motor: w/o Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut Included, Mounting: Rod Flange, Actuator Cable Length: 3m, Controller Type (LEC, JXC): JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Rail Mounting
LECP1 series is a programless controller capable of setting up an electric actuator operation without using a PC or teaching box. Through the combination of parallel I/O inputs, 14 points of positioning are available. The speed and acceleration of the positioning can be set by the switch for each operating direction. A single signal sent to a dedicated terminal returns an actuator to
PNP PARALLEL I/O DC CONTROLLER, ELECTRIC ACTUATOR CONTROLLER, N31, 0.32 lb
A B C D Maximum Speeds for Each Transfer Load Unit (mm/s) Transfer load (kg) 15 20 25 30 1000 1000 930 740 600 500 Note Model LJ1H202PC-500LJ1H202PC-600LJ1H202PC-700LJ1H202PC-800LJ1H202PC-900LJ1H202PC-1000700 700 600 600 500 500 500 500 500 500 500 500 500 500 500 500 500 500 Power supply: 100/110(V)AC 10% Compatible controller: LC1-1B2H1Power supply: 200/220(V)AC 10% Compatible controller
A B C D Maximum Speeds for Each Transfer Load Unit (mm/s) Transfer load (kg) 15 20 25 30 1000 1000 930 740 600 500 Note Model LJ1H202PC-500LJ1H202PC-600LJ1H202PC-700LJ1H202PC-800LJ1H202PC-900LJ1H202PC-1000700 700 600 600 500 500 500 500 500 500 500 500 500 500 500 500 500 500 Power supply: 100/110(V)AC 10% Compatible controller: LC1-1B2H1Power supply: 200/220(V)AC 10% Compatible controller
INDEX 270 Series EX600 SI Unit Specifications All Units Common Specifications 10 to 50C 20 to 60C 35 to 85% RH (No dew condensation) 500 VAC for 1 minute between external terminals and FE 500 VDC, 10 M or more between external terminals and FE Operating temperature range Storage temperature range Operating humidity range Withstand voltage Note) Insulation resistance Note) Environmental resistance
A B C D Maximum Speeds for Each Transfer Load Unit (mm/s) Transfer load (kg) 15 20 25 30 1000 1000 930 740 600 500 Note Model LJ1H202PC-500LJ1H202PC-600LJ1H202PC-700LJ1H202PC-800LJ1H202PC-900LJ1H202PC-1000700 700 600 600 500 500 500 500 500 500 500 500 500 500 500 500 500 500 Power supply: 100/110(V)AC 10% Compatible controller: LC1-1B2H1Power supply: 200/220(V)AC 10% Compatible controller