The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Series LECP6 controller has two available modes for the setting software and teaching box.? In the easy mode, the operation can be started by only setting the speed, position, etc.? Using the normal mode allows a further detailed setup.??A few of the?main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, STEP NPN, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, 2.75577 lb, Stroke [mm]Model3050100150200250300350400450500Manufacturable stroke range [mm]LEY32PPPPPPPPPPP20 to 500
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, SLIDER, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, 13.00727 lb, Stroke [mm]Model3050100150200250300350400450500Manufacturable stroke range [mm]LEY32PPPPPPPPPPP20 to 500
Series LECP6 controller has two available modes for the setting software and teaching box.? In the easy mode, the operation can be started by only setting the speed, position, etc.? Using the normal mode allows a further detailed setup.??A few of the?main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, STEP PNP, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, 1.98416 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, 4.18878 lb
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
flow rate, (4) Power supply: 400 VAC 5: (1) Ambient temperature: 32 oC, (2) Circulating fluid: Clean water, (3) Circulating fluid temperature: 20 oC, (4) Load: Refer to the specified cooling capacity (5) Circulating fluid flow rate: Rated flow rate, (6) Power supply: 400 VAC, (7) Piping length: Minimum 6: With pressure control function using an inverter.
, (5) Circulating fluid flow rate: Rated flow rate, (6) Power supply: 400 VAC, (7) Piping length: Minimum 5 With the pressure control mode that controls the pressure automatically with the inverter.If the pressure control mode is not necessary,use the flow control function or the pump output setting function. 6 Required flow rate to maintain the cooling capacity.
Ambient temp. 500 Heating capacity [W] Heating capacity [W] 400 40 40 400 32 32 300 300 25 25 5 5 200 200 100 100 0 0 10 15 20 25 30 35 40 10 15 20 25 30 35 40 Circulating fluid temperature [] Circulating fluid temperature [] 50Hz 60Hz Fig 9-11 Heating capacity (HRR010-A-20-) 9.5.4 HRR010-W-20400 400 Facility water temp.
Key lock relese, DS unlock Key lock relese, DS lock Key lock, DS unlock Key lock, DS lock Key lock relese, DS unlock Common Device access locks Operation pressure Sets the pressure in the operation mode. 0 to 1050 kPa 400 kPa Common Sets the pressure in the standby mode.
8 to 500 30 to 1200 20 to 1000 10 to 500 401 to 500 20 to 1100 12 to 750 6 to 400 24 to 1300 16 to 950 8 to 500 30 to 1200 20 to 1000 10 to 500 501 to 600 20 to 900 20 to 540 20 to 270 24 to 1200 16 to 800 8 to 400 30 to 1200 20 to 1000 10 to 500 601 to 700 20 to 630 20 to 420 20 to 230 24 to 930 16 to 620 8 to 310 30 to 1200 20 to 900 10 to 440 Speed [mm/s] Stroke 701 to 800 20 to 550 20
USB 7. 106 No.SFOD-OMT0009CN-B 7. 7. 4. ( EMG ) 4. 107 No.SFOD-OMT0009CN-B 1. 1.1 LEY/LEYG LEY16/LEYG16 LEY25/LEYG25 LEY32/LEYG32 LEY40/LEYG40 A B C A B C A B C A B C [mm] 10 5 2.5 12 6 3 16 8 4 16 8 4 [mm] 300 300 300 400 400 400 500 500 500 500 500 500 [mm/s] 500 250 125 500 250 125 500 250 125 300 150 75 [mm/s] 15 8 4 18 9 5 24 12 6 24 12 6 () [mm/s] 22 12 6 26 13 7 34 17 9 34
JXC-OMU0026 Supplement 1.3 Initial setting of LES(H) series Model LES(H)8 LES(H)16 LES(H)25 Lead symbol J K J K J K Lead [mm] 8 4 10 5 16 8 Max. speed [mm/s] 400 200 400 200 400 200 Min. speed [mm/s] (Independent and interpolation) 20 10 20 10 20 10 Min. speed [mm/s] (Speed tuning control) 25 13 27 14 30 15 Supplement 1.4 Initial setting of LEP series Model LEP8 LEP16 Lead symbol J K J K
-107No.JXC-OMT0001CN-C 1. 1.1 LEY/LEYG LEY16/LEYG16 LEY25/LEYG25 LEY32/LEYG32 LEY40/LEYG40 A B C A B C A B C A B C [mm] 10 5 2.5 12 6 3 16 8 4 16 8 4 [mm] 300 300 300 400 400 400 500 500 500 500 500 500 mm/s 500 250 125 500 250 125 500 250 125 300 150 75 [mm/s] () 15 8 4 18 9 5 24 12 6 24 12 6 [mm/s] () 22 12 6 26 13 7 34 17 9 34 17 9 1.2 LEFS LEFS16 LEFS25 A B H A B [mm] 10 5 20
Actuator Specifications Supplement 1.1 Initial setting of LEY/LEYG series Model LEY16/LEYG16 LEY25/LEYG25 LEY32/LEYG32 LEY40/LEYG40 Lead symbol A B C A B C A B C A B C Lead [mm] 10 5 2.5 12 6 3 16 8 4 16 8 4 Stroke (mm) 300 300 300 400 400 400 500 500 500 500 500 500 Max. speed [mm/s] 500 250 125 500 250 125 500 250 125 300 150 75 Min. speed [mm/s] (Independent and interpolation) 15 8 4 18
Actuator Specifications Supplement 1.1 Initial setting of LEY/LEYG series Model LEY16/LEYG16 LEY25/LEYG25 LEY32/LEYG32 LEY40/LEYG40 Lead symbol A B C A B C A B C A B C Lead [mm] 10 5 2.5 12 6 3 16 8 4 16 8 4 Stroke [mm] 300 300 300 400 400 400 500 500 500 500 500 500 Max. speed [mm/s] 500 250 125 500 250 125 500 250 125 300 150 75 Min. speed [mm/s] (Independent and 15 8 4 18 9 5 24 12 6 24
Applicable stroke table Stroke [mm] Size 200 300 400 500 600 800 1000 1200 1500 Manufacturable stroke range [mm] 100 200 to 1500 *Please consult with SMC for non-standard strokes as they are produced as special orders. -4- 1.1.2 Specification Model LEJS100T9H LEJS100T9A LEJS100T9B Stroke [mm] *1 200300400500600800100012001500 3000(mm/s2) 60 150 400 5000(mm/s2) 43 93 150 Horizontal 9800(mm
mm] L4 m Overhang direction:L4[mm] 600mm stroke 200 200 600mm stroke or less 500mm stroke or less 150 150 100 100 50 50 0 0 0 1 2 3 4 5 0 1 2 3 4 5 Workload[kg] Workload[kg] 500 500 600mm Wall Mounting 500mm or less Overhang direction:L5[mm] 400 400 Overhang direction:L5[mm] 300 m 300 600mm stroke or less L5 200 200 100 100 0 0 0 1 2 3 4 5 0 1 2 3 4 5 Workload[kg] Workload[kg] 300 300 250