or 3/8" 67.0 67.0 60 121 7380 1 10 mm or 3/8" 75 189 11500 1 10 mm or 3/8" 502 195 11900 1 10 mm or 3/8" 130.0 130.0 602 282 17200 1 10 mm or 3/8" 752 441 26900 1 10 mm or 3/8" B1J B1JA Stroke volume dm3 / in3 NPT Piping Air (s) Spring (s) Piping Air (s) Spring (s) Piping Air (s) Spring (s) 6 0.47 28.7 3/8 10 mm or 3/8" [6 mm or 1/4" (x)] 10 mm or 3/8" [6 mm or 1/4" (x)] 8 0.9 55

Use a fluid with a kinematic viscosity of 50 mm2/s or less.

Rated voltage S L Z S L Z With surge voltage suppressor With light With light/ surge voltage suppressor With surge voltage suppressor With light With light/ surge voltage suppressor AC/ DC Voltage symbol Voltage P DIN Connector Part No.

.: Fieldbus H System S kit 1 to 8 stations 16 Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (16 output points) Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (8 output points) DeviceNet OMRON Corp.: CompoBus/S (16 output points) OMRON Corp.: CompoBus/S (8 output points) CC-Link 1 to 4 stations 8 D side 1 to 8 stations 16 Serial transmission kit EX140 Integrated-type (For Output

1 s/2 s Output protection Output mode Response time Note 6) Voltage output Current output Short circuit protection Flow rate Select from hysteresis mode, window comparator mode, accumulated output mode, or accumulated pulse output mode. 0.5 s/1 s/2 s (linked with the switch output) Voltage output: 1 to 5 V Output impedance: 1 k7 Analog output Output current: 4 to 20 mA Max. load impedance

Nil 3 S n Auto switch Nil Without auto switch Refer to the table below for the applicable auto switch model.

Compressor [Calculation conditions] 50% of the total air consumed in the factory passes through the S coupler, and 4 S couplers are used at the end of the line.

T[s] = (V/10) X (T2 T1)/(Z) T(s) = (4.8/10) X (12 3.7) = 4 NO NO Increase number of booster regulators (Z) to decrease T.

L Speed: V [mm/s] a1 a2 T1 = V/a1 = 300/3000 = 0.1 [s], T3 = V/a2 = 300/3000 = 0.1 [s] Time T = T1 + T2 + T3 + T4 [s] [s] L 0.5 V (T1 + T3) V T1: Acceleration time and T3: Deceleration time can be found by the following equation.

Option Material Code Specification Standard High inlet pressure (Max. inlet pressure 3000 psig (20.7 MPa)) 5) Ports Diaphragm Nozzle Code Body Brass Poppet No code Material Code S, SH V V V V B S SH Ports 316 SS Hastelloy C-22 Hastelloy C-22 B 316 SS HR Hastelloy C-22 2P 3P 4PL 5PC Refer to the following porting configurations.

AS 0 0.1 0.15 0.2 0.25 0.3 Return stroke pressure (MPa) ASP ASN v v w w a a o o l l v v l l F F e e AQ ASV u u r r e e s s v v s s a a e e l l v v r r P P e e AK ASS ASR ASF Working stroke Working stroke Return stroke Return stroke Pressure valve Flow valve 15-16-1 2 Cuts air consumption by operating the return stroke at a reduced pressure.

Yes 8 mm 12 mm 10 mm 25 mm 32 mm Number of auto switches Nil S 2 pcs. 1 pc.

Load operation time [s] < Switch operation time [mm] / piston speed [mm/s] Detect the intermediate position of the stroke Reduce the piston speed until the formula is satisfied Load does not operate -18No.D-S-OMI0002-C Specifications Specifications PLC: Programmable Logic Controller Model No.

For subsonic range Where P1 + 0.1013 = (1 to 2) (P2 + 0.1013) Formula based on Cv factor Q = 197.8Cv P (P2 + 0.1013) kg/h Formula based on effective area Q = 11.0S P (P2 + 0.1013) kg/h [650] (133) 0.2 [646] (120) 0.1 S = 2.8mm S = 5.9mm S = 9.2mm S = 11.7mm S = 6.3mm S = 9.7mm S = 14.4mm S = 10.8mm S = 15.3mm S = 24.8mm Flow rate Q kg/h VCS212 VCS213 VCS214 VCS215 VCS 13 VCS314 VCS315

Rise time 1 ns Weight Note 3) 410 g 470 g 650 g 1,100 g Port size (Rc, NPT, G) 3/8 3/8, 1/2 1/2, 3/4 3/4, 1 Note 1) The system accuracy when combined with PF2W2/3.

For subsonic range Where P1 + 0.1013 = (1 to 2) (P2 + 0.1013) Formula based on Cv factor Q = 197.8Cv P (P2 + 0.1013) kg/h Formula based on effective area Q = 11.0S P (P2 + 0.1013) kg/h [650] (133) 0.2 [646] (120) 0.1 S = 2.8mm S = 5.9mm S = 9.2mm S = 11.7mm S = 6.3mm S = 9.7mm S = 14.4mm S = 10.8mm S = 15.3mm S = 24.8mm Flow rate Q kg/h VCS212 VCS213 VCS214 VCS215 VCS 13 VCS314 VCS315

The piston speed may exceed the maximum operating speed of 500mm/s if the piping is directly connected to the cylinder. Please use speed controllers by SMC to adjust the piston speed so that it will not exceed 500mm/s.

VXS VXS VXB VXE (3) Formula for flow rate When P2 + 0.1 0.5, choked flow P1 + 0.1 293 Q = 120 x S (P1 + 0.1) (3) 273 + T When P2 + 0.1 > 0.5, subsonic flow P1 + 0.1 293 Q = 240 x S (P2 + 0.1) (P1 P2) (4) 273 + T Conversion with sonic conductance C: VXP VXR VXH VXF VX3 VXA S = 5.0 x C(5) Q : Air flow rate[L/min(ANR)] S : Effective area [mm2] P1 : Upstream pressure [MPa] P2 : Downstream

Valve-coil(s) short circuit 1 1 0...15 Valve coil of the applicable ejector has a short circuit. Pressure sensor(s) short circuit 0 1 0 At least one pressure sensor has a short circuit. Pressure sensor(s) failure or disconnection 1 1 0...15 Pressure sensor of the applicable ejector has a failure or a disconnection.