SMC Corporation of America
Elite Part Number Search
Search Results "KN-Q06A-150"

Magnet: D (Built-in), Mounting: L (Axial Foot), Style: Aluminum Tube, Bore Size: 63mm, Thread: TN (NPT), Stroke: 100mm, Option: KN [Heat Resistant Tarpaulin, Cushion: None (For Air-hydro Select K)], Lock Operation: E [Spring Lock (Lock Exhaust)]

Magnet: D (Built-in), Mounting: T (Center Trunnion), Style: Aluminum Tube, Bore Size: 50mm, Thread: TN (NPT), Stroke: 100mm, Option: KN [Heat Resistant Tarpaulin, Cushion: None (For Air-hydro Select K)], Lock Operation: E [Spring Lock (Lock Exhaust)]

Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Bore Size: 80mm, Thread: TF (G), Stroke: 125mm, Option: KN (Heat Resistant Tarpaulin + Rubber Bumper)

Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Bore Size: 80mm, Thread: TN (NPT), Stroke: 125mm, Option: KN (Heat Resistant Tarpaulin + Rubber Bumper)

Magnet: D (Built-in Magnet), Mounting: L (Axial Foot), Bore Size: 50mm, Thread: TN (NPT), Stroke: 600mm, Option: KN (Heat Resistant Tarpaulin + Rubber Bumper)

Magnet: D (Built-in Magnet), Mounting: L (Axial Foot), Bore Size: 50mm, Thread: TN (NPT), Stroke: 600mm, Option: KN (Heat Resistant Tarpaulin + Rubber Bumper), Bracket: No Bracket, Knuckle Joint: No Bracket, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: Z (5m), Number: 3 pcs.

Actuation: 1 (2 Position Single), Seal: 0 (Metal Seal), Function: KN (K + N), Voltage: 5 (24VDC), Manual Override: Non-locking Push Type, Tool Required, Cylinder Port: C4 (Side Ported ø4 One-touch Fitting), Plug Mount Port: None, Manifold Block: w/o Manifold Block, CE Compliant: Q (CE Compliant)

Actuation: 3 (3 Position Closed Center), Seal: 0 (Metal Seal), Function: KN (K + N), Voltage: 5 (24VDC), Manual Override: Non-locking Push Type, Tool Required, Cylinder Port: N7 (Side Ported 1/4" One-touch Fitting), Plug Mount Port: None, Manifold Block: M (w/Manifold Block)

Actuation: 3 (3 Position Closed Center), Seal: 0 (Metal Seal), Function: KN (K + N), Voltage: 5 (24VDC), Manual Override: Non-locking Push Type, Tool Required, Cylinder Port: N7 (Side Ported 1/4" One-touch Fitting)

Actuation: 4 (3 Position Exhaust Center), Seal: 0 (Metal Seal), Function: KN (K + N), Voltage: 5 (24VDC), Electrical Entry: L (Plug Lead Connector w/300mm Lead Wire, Manual Override: Non-locking Push Type, Tool Required, Cylinder Port: C6 (Side Ported ø6 One-touch Fitting)

Actuation: 4 (3 Position Exhaust Center), Seal: 0 (Metal Seal), Function: KN (K + N), Voltage: 5 (24VDC), Electrical Entry: LO (Plug Connector w/o Connector), Manual Override: Non-locking Push Type, Tool Required, Cylinder Port: C6 (Side Ported ø6 One-touch Fitting)

If the lodged portion is left on without being removed, it may result in air leakage and make the removal of the tubing difficult. (2) Connection of the metal rod accessories Plug-in fittings with metal rods (KC series, KQ2 series, former KQ series, KN series, KM series, etc.) cannot be connected to one-touch fitting.

If the lodged portion is left on without being removed, it may result in air leakage and removal of the tubing difficult. (2) Connecting products with metal rods After attaching products with attached metal rods (KC series, old KQ series, KN series, and KM series) to the One-touch fitting, do not use tubes, resin plugs, or reducers, etc.

With the release of the KN series nozzles and gauge heads 30~90% of air consumption required for the current nozzle operation can be saved with the appropriate selection of the new nozzle and sizing. Many variations of nozzle are available with tube materials including nylon, soft nylon, soft copper pipe and OST tubing.

Mounted directly to unlocking port Maximum value taken from the range of 100 measured stopping positions Holding Force for Spring Locking (Maximum Static Load) 125 140 160 Bore size (mm) 8.4 {859} 10.5 {1077} 13.8 {1407} Holding force KN {kgf} Be sure to make cylinder selections in accordance with the method given on page 30. 2 Series CLS Mounting Brackets/Part Numbers Rod Boot Materials

1.0 2.0 Spring locking Conditions/Horizontal, supply pressure P = 0.5MPa {5kgf/cm} Load weight Upper limit of allowed values Solenoid valve for locking Mounted directly to unlocking port Maximum value taken from the range of 100 measured stopping positions Holding force for Spring Locking (Maximum Static Load) 125 140 160 Bore size (mm) 8.4 {859} 10.5 {1077} 13.8 {1407} Holding force KN

Example: -KN Note 2) Be sure to indicate the wiring specifications in the specification order sheet. Manifold 1 Plug-in unit Stations Input block COM. (Fill out for I/O unit only) 01 1 station Nil PNP (+) or without SI unit/input block(SD0) NPN () N The maximum number of stations differs depending on the electrical entry.

S coupler: Series KK Blow nozzle: Series KN Regulator: Series AR Filter regulator: Series AW

With the release of the KN series nozzles and gauge heads 30~90% of air consumption required for the current nozzle operation can be saved with the appropriate selection of the new nozzle and sizing. Many variations of nozzle are available with tube materials including nylon, soft nylon, soft copper pipe and OST tubing.