SMC Corporation of America
Elite Part Number Search
Search Results "ISE20-N-P-N01-LD"

Rated Vacuum Range: -101 to 0 kPa, Output Specification: N (NPN Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: N (NPN Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover)

Model: 0 to -101kPa, Piping: NPT 1/8, M5 Female, Output: NPN Open Collector 1 Output, Display Unit: w/Unit Display Switching Function, Lead Wire: Lead Wire w/Connector, Bracket/Panel Mount Adapter: Panel Mount Adapter+Front Protection Cover, Operating Manual/Certificate: -, Made to Order: -

Model: -100 to 100kPa, Piping: NPT 1/8, M5 Female, Output: NPN Open Collector 1 Output, Display Unit: w/Unit Display Switching Function, Lead Wire: Lead Wire w/Connector, Bracket/Panel Mount Adapter: Panel Mount Adapter+Front Protection Cover, Operating Manual/Certificate: -, Made to Order: -

For stopping accuracy, refer to Series CLJ (P. 9-2-12), Series CLM2 (P. 9-2-20), Series CLG1 (P . 9-2-30), and Series CL1 (P . 9-3-2) respectively. 7. In order to further improve stopping accuracy, the time from the stop signal to the operation of the lock should be shortened as much as possible.

Output Specification: N (NPN Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (M5 Female Thread), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover)

Nm N M1 M M3 W W2 W W4 ML2B25 10.0 1.2 3.0 200.0 58.0 65.0 100.0 ML2B32 20.0 2.4 6.0 300.0 80.0 96.0 150.0 ML2B40 40.0 4.8 12.0 500.0 106.0 140.0 250.0 ML2B25 ML2B32 ML2B40 J 0.43 0.68 1.21 18 ML2B/M1 ML2B/W1 ML2B/W1 0 0 0 Nm 0 0 0 N N 0 m/s m/s m/s ML2B/M2 ML2B/W2 ML2B/W2 N m N N m/s ML2B/M3 m/s m/s 20 ML2B/W3 ML2B/W3 10 Nm 5 3 2 1 N N m/s m/s m/s ML2B/W4 500 N 00 N

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter + Front Protection Cover, Option 3: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover)

[I (mm) c l BonI.1iIi (mm) A L[) R N X Y LG L 0 ~ t::;r H LH L1 . 50s 107 .2 15 39 18 9 5 Ml0Xl.S 14.7 43.5 MSl(l .25 14 M8x 1.25 B 15 46 18 Ml0xl.5 16.2 43.5 Ml0xl .5 18 9 11 5 Ml0Xl.5 63 112.7 M12xl .75 22 M12xt.75 19.5 11 53.5 13 7 MI6X2.0 59 20 21 80 133 .5 Rod Side Flange: COQ2FP 0-0 OM-DO 4-oFO 40 Thread d Ih A SpeCIal cap bolt 4-N . rBote size A L 0 R N FD FT FV FX F2 Ll H C !

Made to order options (see Page 55) Low temperatureresistant (XB6) resistant Modification of rod end auto switch Page P 8 P 1 7 P32 fechnical Data Auto switch guide P 4 6 P 3 8 ?

Piping: NPT 1/8, M5 Female, Output: PNP Open Collector 1 Output, Display Unit: w/Unit Display Switching Function, Lead Wire: Lead Wire w/Connector, Bracket/Panel Mount Adapter: Panel Mount Adapter+Front Protection Cover, Operating Manual/Certificate: -, Made to Order: -

Piping: NPT1/8 w/M5 Female Thread, Output Specification: PNP Open Collector, 1 Output, Unit Specification: w/Unit Conversion Function (Not Allowed for Use in Japan), Option 1: Bracket D, Option 2: -

Model: 0 to -101kPa, Piping: NPT 1/8, M5 Female, Output: PNP Open Collector 1 Output, Display Unit: w/Unit Display Switching Function, Lead Wire: Lead Wire w/Connector, Bracket/Panel Mount Adapter: Panel Mount Adapter+Front Protection Cover, Operating Manual/Certificate: -, Made to Order: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter + Front Protection Cover, Option 3: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter + Front Protection Cover, Option 3: -

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover)