SMC Corporation of America
Elite Part Number Search
Search Results "IS10T-40-02-L-D"

r^rE_aEIl_I ItrtrElEll+trMElr cG1 C D G l T T series i I .2: 3. .4, i.5. .6-l '?

20 54.0 SET side pressure (kPa) 30 Set pressure (kPa) 54.5 40 55.0 50 Set point 60 55.5 70 56.0 80 56.5 90 100 0 20 40 60 80 100 120 57.0 100 95 90 85 80 75 70 65 60 Flow rate (l/min (ANR)) VAC side pressure (kPa) IRV3000 IRV3000 0 53.0 10 53.5 20 54.0 SET side pressure (kPa) 30 Set pressure (kPa) 54.5 40 55.0 50 Set point 60 55.5 70 56.0 80 56.5 90 57.0 100 95 90 85 80 75 70 65 60 100 0

DO NOT k i id hi d l h b i d HRX-OM-O021 Chapter 1 Safety Instructions 1.3.4 Locations of Hazard Labels There are various warning labels on the product to show the potential hazards.

Model Model L D L D TCU0805-1-N-X6 TCU0425-1-N-X6 1 N x 8 31 3 to 90 L x 5.2 + 200 N x 4 18 1 3 to 90 L x 5.9 + 200 8 5 TCU0805-2-N-X6 TCU0425-2-N-X6 2 42 L x 3 + 200 3 to 40 N x 16 L x 4.4 + 200 N x 8 2 3 to 90 4 2.5 28 TCU1065-1-N-X6 TCU0425-3-N-X6 52 1 3 to 45 L x 5 + 200 N x 10 N x 12 3 3 to 63 L x 2.9 + 200 28 10 6.5 TCU1065-2-N-X6 TCU0604-1-N-X6 2 3 to 35 52 L x 3 + 200 N x 20 L x 5.3

) Oil (Standard) (D, E) High temperature oil (3) (S) (D) 99 100 183 AC DC AC DC 60 40 80 60 60 40 40 60 Maximum Minimum 1 10 5 (2) 10 (1) Note 1) Dew point: 10C or less Note 2) 50 cSt or less Note 3) D, E etc. in parentheses are option symbols.

VXZ2230 VXZ2232 VXZ2240 VXZ2242 VXZ2350 VXZ2352 VXZ2360 VXZ2362 H Y F X E W D U V C S T B K R A J N Q N 79.5 87.5 101.5 106.5 L 108 117 130 135 1 4 3 8 , 28 35 43 45 26 30 38 43 14 17 22 22 7.5 8.5 9 9 24 33 42 47 1.6 2.3 2.6 2.6 22 28 36 42 5.5 6.5 6.5 6.5 40 52 65 70 6 7 7 7 11 14 18 21 93 102 115.5 120.5 25 25 28 28 89 97 112 117 67 75 87 92 50 63 80 90 23 23 25.5 25.5 35 35 40 40 25.5

Common exhaust: VV3P3-41Stations 1-02 (G) (E) (T) (D, Y) N.C. N.O.

[mg/L] 70 or less 200 or less Calcium hardness [mg/L] 50 or less 150 or less Ion silica [mg/L] 30 or less 50 or less Iron [mg/L] 0.3 or less 1.0 or less Copper [mg/L] 0.1 or less 0.3 or less Sulfide ion [mg/L] Not detected Not detected Referential Ammonium ion [mg/L] 0.1 or less 1.0 or less item Residual chlorine [mg/L] 0.3 or less 0.3 or less Separation carbonic acid [mg/L] 4.0 or less

ISO Interface Solenoid Valve/SIZEq Metal Seal SeriesVS7-6 Single solenoid (FG-S) Double solenoid (FG-D) Reverse pressure (YZ-S) Reverse pressure (YZ-D) 2 position 3 position SV SY VS7-6-FPG-D Closed centre (FHG-D) Exhaust centre (FJG-D) Double pilot check (FPG-D) Pressure centre (FLG-D) SYJ SX VS7-6-FHG-D Option VK Standard Specifications 5 to 60 oC 0.1 to 1.0MPa Air/lnert gas Fluid Operating

Branch Y: KQ2U Model H (Width across flats) D M L A Weight (g) Applicable tubing O.D.

(Blinks at 0.4 second intervals) Light is turned off. 6 5 4 3 2 1 ON 10 9 8 7 6 5 4 3 2 1 ON ON ON L ERR L RUN L ERR PWR(V) PWR COM C COM D COM A COM B INPUT When COM A to D are receiving data. When COM A to D are not receiving data. Light is turned on. Light is turned off. COM A to D Input unit (Input device) is connected and will illuminate when communication is working properly.

Note 1) 20 16 17 Elbow for piping port/IZN10D B C 180 10 (mm) B Model C 16 D 11.5 IZN10-16 (mm) IZN10-17 (inch) 22 24.5 18.5 12 Female threads for piping (Rc1/8)/IZN10-11 16 Rc1/8 13 Width across flats 14 456 Ionizer IZN10 Series Dimensions L-bracket/IZN10-B1 IZS (Mounting angle adjustable range) 40 7.5 17 IZN IZN 2 x R10 3.4 2 x M3 2 x 3.4 IZF 25 40 5 ZVB 50 Internal mounting IZD IZE 20.5

O-ring Port plug Body Ported Base Mounted Blanking plug (For One-touch fittings) KJP-02 A L Dimensions [mm] Applicable fitting size d Model A L D Weight [g] 2 KJP-02 8.2 17 3 0.1 3.2 KQ2P-23 16 31.5 5 1 4 KQ2P-04 16 32 6 1 23 KQ2P-04 D Silencer (For manifold EXH port) Body Ported Base Mounted Silencer is installed in the EXH port.

min) 7.9 gpm (30 L/min) 1.1 gpm (4 L/min) 10.6 gpm (40 L/min) Circulating fluid rated flow 4.0 gpm (15 L/min) 6.6 gpm (25 L/min) 2.6 gpm (10 L/min) 10.6 gpm (40 L/min) Facility water required flow rate Temperature stability Note 3) 0.54F (0.3C) Pump capacity Note 4) (50/60 Hz) 0.45/0.65 (at 15 L/min) 0.40/0.60 (at 30 L/min) 0.35/0.55 (at 4 L/min) 0.35/0.55 (at 40 L/min) Circulating fluid

Stainless Steel (mm) A B C D E F G H J L Bracket part no.

Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia TEL: 02-6761574 FAX: 02-6708173 15-18-21

Function 5.4 Operation of Controller 5-7 A_HEC-OM-J004-4 Chapter 5 Operation PV [Tips] SV Status when temp. upper/lower deviation limit alarm occurs (at the time of shipment from the factory) O U T 1 O U T 2 Lights up when A L 2 C O M R D Y D I A L 1 temp. upper / lower deviation limit alarm occurs. AL1 LED lights up when temp. upper/lower deviation limit alarm occurs.

40 VDW Air consumption 100 l/min (ANR) Air consumption 200 l/min (ANR) 30 30 Air consumption 100 l/min (ANR) Air consumption 50 l/min (ANR) VQ 20 SUP = 0.2 MPa 20 SUP = 0.2 MPa VX2 10 10 VX 0 0 10 30 40 50 20 60 VX3 10 20 Discharge rate (l/min) Discharge rate (l /min) VXA Selection from Flow Characteristic Graph (PA3000) VN Required specifications example: Find the pilot air pressure and

Fitting plug KQP-01 KQP-03 KQP-07 KQP-09 KQP-11 Dimensions L (mm) A Applicable fitting size d A L D Part number KQP-01 KQP-03 KQP-07 KQP-09 KQP-11 5 6 8.5 10 11.5 31.5 32 35 39 43 1/8 5/32 1/4 5/16 3/8 16 16 18 20.5 22 D Used to block unused cylinder port. L DIN rail AXT100-DR12.5 (Pitch) 5.25 7.5 Suffix number into from the dimension table below.