Power saving circuit is only available in the "Z" type.
Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-0004 JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Printed in Japan. 1st printing August, 1998 D-SMC.L.A. P-69.5 (JT)
Nil Without port (For manifold) (8A) 1 4 02 Electrical entry Light/Surge voltage suppressor CE-compliant CE-compliant G Grommet, 300 mm lead wire H Grommet, 600 mm lead wire Electrical entry D T C H G Only"D" Symbol Nil S Z C Conduit Note) Note) T Conduit terminal Note) D DIN terminal Symbol S: With surge voltage suppressor Note) Refer to the figure below.
www.stevenengineering.com I 7.24 INSTRUMENTATION ELECTRO-PNEUMATIC REGULATOR D I M E N S I O N S S E R I E S VY140 0 102 03 04 D I M E N S I O N S S E R I E S VY150 0 102 03 04 D I M E N S I O N S S E R I E S VY170 0 110 12 D I M E N S I O N S S E R I E S VY190 0 114 20 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 !
Example) 10-ARP30K-03BE-1RY Clean room compliant, copperfree, fluorine-free, silicon-free Clean room compliant Copper-free, fluorine-free Symbol 20 30 40 Body size Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without
AL-OMQ0006-C PRODUCT NAME LUBRICATOR MODEL / Series / Product Number AL10-M5(-2,3,6,R,Z)-A AL20-(F,N)01(F,N)02(B)(-2,3,6,C,R,Z)-A AL30-(F,N)02(F,N)03(B)(-2,3,6,8,R,3W,Z)-A AL40-(F,N)02(F,N)04(B)(-2,3,6,8,R,3W,Z)-A AL40-(F,N)06(B)(-2,3,6,8,R,3W,Z)-A AL50-(F,N)06(F,N)10(B)(-2,3,6,8,R,3W,Z)-A AL60-(F,N)10(B)(-2,3,6,8,R,3W,Z)-A Contents Page 1. SAFETY INSTRUCTIONS 1-5 2. APPLICATION 6 3.
How to Order ARP 30 03 BE K Option / Semi-standard: Select one each for a to f. Option / Semi-standard symbol: Enter them alphanumerically.
C 30 D Refer to page 300 for mounting.
Weight [g] Auto switch model D-M9NW(V) D-M9PW(V) D-M9BW(V) Auto Switch Internal Circuit 0.5 8 8 7 D-M9NW/M9NWV 1 14 14 13 Lead wire length (m) 3 41 41 38 DC (+) Brown 5 68 68 63 Main circuit of switch OUT Black How to Order D-M9 N W V L DC () Blue Series Lead wire length D-M9PW/M9PWV Nil 0.5 m M 1 m L 3 m Z 5 m Nil In-line V Perpendicular Wiring/Output type DC (+) Brown Electrical entry N
The load factor for each direction can be obtained as follows. x = 0/250 = 0 y = 50/180 = 0.27 z = 200/1000 = 0.2 5. x + y + z = 0.47 1 1500 1500 1000 800 1000 1000 Lz 600 L3 [mm] L1 [mm] L2 [mm] 400 500 500 200 Ly Lx 0 10 20 30 40 50 60 0 0 10 20 30 40 50 60 0 0 10 20 30 40 50 60 0 Work load [kg] Work load [kg] Work load [kg] 670 Model Selection LEFS Series AC Servo Motor Table Accuracy
D-H7l D-H7C D-G5l/K59 D-G5lW/K59W D-G59F D-G5NT D-G5BA D-C7l D-C80 D-C73C D-C80C D-B5l D-B64 D-B59W D-A9l D-A9lV Bore size A B A B A B A B A B A B A B 20 33 24 (32) 29 20 (28) 28.5 19.5 (27.5) 29.5 20.5 (28.5) 25 16 (24) 23.5 14.5 (22.5) 26.5 17.5 (25.5) 25 32.5 24.5 (32.5) 28.5 20.5 (28.5) 28 20 (28) 29 21 (29) 24.5 16.5 (24.5) 23 15 (23) 26 18 (26) 32 34 25 (33) 30 21 (29) 29.5 20.5 (28.5
AR 30 q 03 t y K r BE B Option/Semi-standard: Select one each for a to g. Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order.
Example) 10-ARP30K-03BG-1RY Clean room compliant, copperfree, fluorine-free, silicone-free Clean room compliant Symbol Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without mounting option With bracket With set nut (For
Example) 10-ARP30K-03BG-1RY Clean room compliant, copperfree, fluorine-free, silicone-free Clean room compliant Symbol Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without mounting option With bracket With set nut (For
1.25 15 30 M26 x 1.5 1/8 26 0 0.033 32 45 8 13 12 30 19 30 14 22 9 10 5.5 9 19.5 17 25 6 37.5 M10 x 1.25 15 34.5 M26 x 1.5 1/8 26 0 0.039 40 50 11 16 14 38 30 39 18 24 10 15 7 11 21 22 41.2 8 46.5 M14 x 1.5 21.5 42.5 M32 x 2 1/4 32 Dimensions by Stroke Built-in One-touch Fittings 1 to 50 51 to 100 101 to 150 151 to 200 201 to 250 Bore size (mm) Stroke Q P Symbol S ZZ Z S ZZ Z S ZZ Z Z
S Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R Lead wire length U 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.
8 I 28 33.5 37.5 46.5 K 5 5.5 5.5 7 L 30 30 30 39 MM M8 N 15 15 15 21.5 NA 24 30 34.5 42.5 NN M20 X 1.5 M26 X 1.5 M26 X 1.5 M32 X 2 PG 22 27 27 29 PH 19.5 24 24 24 PL 20 24 24 24 PW 38 41 41 41 RR 9 9 9 11 S 127 137 139 167 U 14 14 14 18 Z 198 212 214 256 ZZ 207 221 223 267 1/8 1/8 1/8 1/4 CXS M10 X 1.25 M10 X 1.25 M14 X 1.5 CXT MX Double Clevis (D) MXU CLM2D Bore size Stroke MXH MXS MXQ
MLU 40 50 63 80 100 125 140 160 Bore size (mm) Bore size (mm) Auto switch model CA-L06 CA-L05 CA-L10 CA-L04 CA-L08 Foot style Rod side 40 50 63 80 100 125 140 160 ML1C CS1-L12 CS1-L14 CS1-L16 D-A5/A6/A59W D-F5/J5/F5NTL D-F5W/J59W D-F5BAL/F59F D-A3/A44 D-G39/K39 D-B5/B6/B59W D-G5/K59/G5BAL D-G5W/K59W D-G59F/G5NTL D-A3C/A44C D-G39C/K39C D-Z7/Z80 D-Y59/Y69 D-Y7P/Y7PV D-Y7W D-Y7WV D-Y7BAL CA1
HEAD OFFICE: 1-16-4, SHIMBASHI, MINATO-KU, TOKYO 105, JAPAN TELEPHONE: 03-3502-2740 FACSIMILE: 03-3508-2480