60 99 16 20.5 138 142 47.5 33.5 50 Rc 3/8, 1/2, NPT 3/8, 1/2 M8 x 1.25 30 36 55 44 11 10 75.5 77 4 20 37 3.5 27 Rc 1/4, NPT 1/4 36 47 80 56 15 19 109.5 111.5 7.5 34 46 5.5 37 Rc 3/8, NPT 3/8 PPS 46 60 99.5 68 22 20.5 138.5 142.5 8 42 57 5.5 50 Rc 1/2, NPT 1/2 30 36 58.5 44 14.5 10 79 80.5 4 20 37 3.5 27 Rc 1/4, NPT 1/4 36 47 84 56 19 19 113.5 115.5 7.5 34 46 5.5 37 Rc 3/8, NPT 3/8
30 36 55 44 11 10 75.5 77 4 20 37 3.5 27 Rc 1/4, NPT 1/4 36 47 80 56 15 19 109.5 111.5 7.5 34 46 5.5 37 Rc 3/8, NPT 3/8 PPS 46 60 99.5 68 22 20.5 138.5 142.5 8 42 57 5.5 50 Rc 1/2, NPT 1/2 30 36 58.5 44 14.5 10 79 80.5 4 20 37 3.5 27 Rc 1/4, NPT 1/4 36 47 84 56 19 19 113.5 115.5 7.5 34 46 5.5 37 Rc 3/8, NPT 3/8 PFA 46 60 99.5 68 22 20.5 138.5 142.5 8 42 57 5.5 50 Rc 1/2, NPT 1/2 484
46 LB 27 31 36 46 46 LA 35.5 41 47 62 62 LA 35 41 46 62 62 L 52.5 59 67 81 84 L 52.5 59 67 81 84 ZZ 115.5 127 137 171 175 Model MU25 MU32 MU40 MU50 MU63 Model MU25 MU32 MU40 MU50 MU63 Applicable pin 8 10 10 14 14 9 11 13 16 16 8 10 10 14 14 9 11 13 16 16 +0.058 0 +0.058 0 +0.058 0 +0.070 0 +0.070 0 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 +0.058 0 +0.058 0 +0.058 0 +0.070 0 +0.070 0 +0.2
Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 m or smaller. 3. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause the malfunction of pneumatic equipment, such as valves.
CD-MU02 Z 142.5 159 171 205.5 LX RR 8.5 10 11 16 LD LU 11 14 15 20 LC 16 18 20 28 Z LB 27 31 36 46 LB 27 31 36 46 LX RR 8 10 10 16 LA 35.5 41 47 62 ZZ 151 169 182 221.5 L 52.5 59 67 81 LA 35 41 46 62 LD LU 13 14 17 23 ZZ L 52.5 59 67 81 Model MLU25 MLU32 MLU40 MLU50 Model MLU25 MLU32 MLU40 MLU50 +0.4 +0.2 +0.4 +0.2 +0.4 +0.2 +0.4 +0.2 The L, Z and ZZ dimensions are reference dimensions when
When in the locked state, do not apply a load accompanied by an impact shock, strong vibration or turning force, etc. Use caution, because an external action such as an impacting load, strong vibration or turning force, may damage the locking mechanism or reduce its life. 2. Consider stopping accuracy and the amount of over-run when an intermediate stop is performed.
Install an air dryer, aftercooler, etc. Excessive condensate in a compressed air system may cause valves and other pneumatic equipment to malfunction. Installation of an air dryer, after cooler etc. is recommended. 3. Drain flushing If condensate in the drain bowl is not emptied on a regular basis, the bowl will over flow and allow the condensate to enter the compressed air lines.
Do not operate with the stroke adjusting unit fixed in an intermediate position. When the stroke adjusting unit is fixed in an intermediate position, slippage can occur depending on the amount of energy released at the time of an impact. In such cases, the use of the adjusting bolt mounting brackets, available per made-to-order specifications -X416 and -X417, is recommended.
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: M (Applicable to Deionized Water Piping)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: J (w/Automatic Fluid Fill Function)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: W (SI Unit Only)
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: Option Combination A+K
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: K (w/Fluid Fill Port)
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: M (Applicable to Deionized Water Piping)
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: Option Combination A+D+K
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: Option Combination D+K
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: A (w/Caster Adjuster foot)
Cooling Capacity: 200, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: None, UL Certification: S (UL Certification)
Cooling Capacity: 200, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: AK (A + K), UL Certification: S (UL Certification)
Cooling Capacity: 200, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: A (w/Caster Adjuster-foot), UL Certification: S (UL Certification)