Body Size: 20, Thread: N (NPT), Port: 02 (1/4), Option: C [Float Type Auto Drain (N.C.)], Attachment: KV (K + V), Semi-Standard 1: 3C (3 + C), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 30, Thread: N (NPT), Port: 02 (1/4), Option: E [Square embedded type pressure gauge (with limit indicator)], Attachment: KV (K + V), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 30, Thread: N (NPT), Port: 03 (3/8), Option: E [Square embedded type pressure gauge (with limit indicator)], Attachment: KV (K + V), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 20, Thread: Rc, Port: 02 (1/4), Option: Standard, Attachment: KV (K + V), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 20, Thread: N (NPT), Port: 01 (1/8), Option: G (Round Pressure Gauge w/Limit Indicator), Attachment: KV (K + V), Semi-Standard 1: 1C (1 + C), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 20, Thread: N (NPT), Port: 01 (1/8), Option: Standard, Attachment: KV (K + V), Semi-Standard 1: 1C (1 + C), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 30, Thread: N (NPT), Port: 03 (3/8), Option: CE (C + E), Attachment: KV (K + V), Semi-Standard 1: 8 (Metal Bowl w/Level Gauge), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 40, Thread: Rc, Port: 04 (1/2), Option: G (Round Pressure Gauge w/Limit Indicator), Attachment: KV (K + V), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 40, Thread: Rc, Port: 04 (1/2), Option: Standard, Attachment: KV (K + V), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Note) Metric size 6, 8, 10 10, 12 Inch size 1/8", 3/16", 1/4" 1/4", 3/8" 3/8", 1/2" LVC Orifice diameter 4.4 8 10 0.4 1.2 1.8 Flow rate characteristics Av x Kv LVA 0.5 1.4 2.2 Cv Withstand pressure (MPa) 1 LVH Operating pressure (MPa) 0 to 0.5 Fluid temperature (C) 5 to 90 LVD Ambient temperature (C) 0 to 60 Weight (kg) LVQ 0.055 0.115 0.185 Note) For details of the applicable tubing sizes
type Port size Nil N Rc1/8 Symbol Body class Applicable PVC piping external diameter NPT1/8 Symbol 25A 32A 40A 50A 65A 80A 6 32 PA 38 8 48 60 B A 9 75 89 PB Standard Specifications Model LVW60 LVW80 LVW90 Nominal diameter 80A 40A 65A 32A 50A 25A Applicable pipe size external diameter 89 48 75 38 60 32 Operating pressure 0 to 0.02 MPa Orifice size 80 65 25 40 Pilot pressure 0.3 to 0.5 MPa Kv
A0202 IZS30 (1 replacement rubber grindstone) Rubber grindstone Felt pad 185 Gun Type Ionizer IZG10 Series Specifications AC Adapter Specifications Ionizer model IZG10 Ion generation method Corona discharge type Method of applying high voltage High frequency AC type Applied voltage*1 2.5 kV Offset voltage*2 Within 10 V Input voltage*4 100 to 240 VAC 50/60 Hz Output voltage 24 VDC 5% Output
Supply pressure: 0.1 MPa (7 L/min (ANR) per nozzle) Installation height of sensor: 10 mm 3 Electrostatic potential [kV] 20 With sensor Ionizer 2 Without sensor Without sensor Discharge time [s] 15 1 With sensor L 0 10 1 Workpiece Without sensor 5 2 With sensor 3 0 500 1000 1500 2000 Installation distance L [mm] 1 2 3 4 Time [s] Run mode after static neutralization (electrostatic potential
The discharge speed has been increased by reading the workpiece's electrostatic potential by the feedback sensor (option) and continuously emitting ions with a reverse polarity. 3 Electrostatic potential (kV) With sensor IZS IZS Detects the polarity of a discharged object and measures the charged voltage. 2 Without sensor 1 IZN 0 IZF 1 Without sensor 2 With sensor ZVB 3 1 2 3 4 Time (s) IZD
Note) Metric size 6, 8, 10 10, 12 Inch size 1/8", 3/16", 1/4" 1/4", 3/8" 3/8", 1/2" LVC Orifice diameter 4.4 8 10 0.4 1.2 1.8 Flow rate characteristics Av x Kv LVA 0.5 1.4 2.2 Cv Withstand pressure (MPa) 1 LVH Operating pressure (MPa) 0 to 0.5 Fluid temperature (C) 5 to 90 LVD Ambient temperature (C) 0 to 60 Weight (kg) LVQ 0.055 0.115 0.185 Note) For details of the applicable tubing sizes
(mm) Model Conversion Cv 1.2 1.3 1.5 3.9 5.0 4.5 5.8 7.0 11 9.1 15 17 23 17 23 26 34 30 40 41 62 41 66 49 70 73 100 Threaded Note) Flange Kv VNC1-6A VNC1-8A VNC1-10A VNC24-10A VNC2-10A VNC24-15A VNC2-15A VNC34-20A VNC3-20A VNC44-25A VNC4-25A VNC54-32A VNC5-32A VNC54-32F VNC5-32F VNC64-40A VNC6-40A VNC64-40F VNC6-40F VNC74-50A VNC7-50A VNC74-50F VNC7-50F 1 8 1 4 1.1 1.1 1.3 3.4 4.3 3.9 5.0
(mm) Model Flange Note) Kv Conversion Cv Rc VND10D-6A VND10D-8A VND10D-10A VND20D-10A VND20D-15A VND30D-20A VND40D-25A VND50D-32A VND50D-32F VND60D-40A VND60D-40F VND70D-50A VND70D-50F 0.9 1.0 1.1 4.3 4.6 8.6 13.6 1.1 1.2 1.3 5.0 5.4 9.9 16 1 8 1 4 7 0.3 3 8 15 0.6 1 2 3 4 20 0.9 1.4 2.3 5.5 3.6 7.2 5.7 25 1 1 4 1 15.7 18 32 32 1 2 1 32.9 38 40 40 2 53.6 50 62 10.8 50 Note) The companion
Proof pressure Ambient temperature Max. operating frequency Mounting position Port size Orifice diameter (mm) Flow rate characteristics Kv Conversion Cv Pilot port size Weight (kg) Face-to-face dimension (mm) 5.5 MPa 10.5 MPa 5 to 50C Note 1) 20 times/min Vertical upwards 1 2 3 8 3 4 1 3 8 1 2 3 4 1 3 8 1 2 3 4 1 7.1 8.7 10.6 14.3 3.9 5.2 6.2 7.3 8 9.5 13 15.7 1.9 3.6 4.5 7.8 0.6
Diaphragm Type Pilot Operated 2 Port Solenoid Valve for High Pressure VXH Series [Option] VX2 Valve Specifications VXK Orifice diameter 10 Max. operating pressure: 2.0 MPa Max. operating pressure differential (MPa) Min.operating pressure differential (MPa) Kv Cv converted C[dm /(sbar)] b Cv Water, Oil, Steam Air Flow rate characteristics Orifice dia.
Mlnalo-kv. Tokyo 105 JAPAN Te/:03-3502-2740 Fax:03-3508-2480 1st pnnhng February 1995.D-036,P-53{M) November 1997, 67 5(RP) SpeclilCatlons are subject to change without pnor notICe Printed In Smgapore and any obltgaltOn on the pa r1 01 the manifacture.