.: Alarm output 1> Power supply voltage 24V DC and load resistance 1k (+ internal resistance 350), Load current = 24V DC / (1k + 350) = Approx. 18mA DC 4: Determination of load resistance of alarm output for intrinsic safety type of explosion protected construction specification.
Number of auto switches mounted Rod boot material Symbol Models 2 pcs. 1 pc. 70C00 Nylon tarpaulin J D-C7, C8 D-B5, B6 D-H7 D-G5, K5 110C Heat resistant tarpaulin K 15mm 10mm The maximum ambient temperature for the rod boot itself. 20mm 15mm D-B59W 20mm 10mm D-H7LF 3 Series CBG1 Rubber Bumper Type: CBG1BN With rear lock: CBG1BN Bore size Stroke H MM H GA GB Width across flats B1 2-Rc
E A F B C D Position For transporting a workpiece to a specific position Pushing For applying force to a workpiece or for measuring the size of a workpiece E A C F B D Setting completed (Download) Step 4 Step 3 Setting of operating conditions -Entering of the operating valuesAfter the operating conditions have been set, Click the [Download] button to complete the settings.
D-SMC, P-63 (M) 2nd printing September 1996. D-SMC, P-59(YG) March 1997. 29(YG) Printed in Japan.
Reduced outgassing Resin materials eliminated Laser marking is employed for the model designation. o u d t g e 2 a c s u s d i Reduction of outgassing due to surface treatment e n o u d t g R e g a 1 c s u s d i e n R g All the external parts (made of aluminum alloy) such as the body and slide table are electroless nickel plated.
Reduced outgassing o u Resin materials eliminated Laser marking is employed for the model designation. d t g e a c 2 s u s d i e Reduction of outgassing due to surface treatment n o u d t R g g e a c 1 s u s d i e n R g All the external parts (made of aluminum alloy) such as the body and slide table are electroless nickel plated.
t o o g e a n L c 2 s u s d Particulate generation has been reduced at the stroke ends by reducing impact using a sine cushion and by stopping the stroke using an internal stopper. i e Reduction of outgassing due to surface treatment n Impact acceleration [m/s2] o u d t R g g e a c 1 s u s d 5 i e n R g All the external parts (made of aluminum alloy) such as the body and slide table are electroless
IZ*-OMP0064 E P r o d u c t Ionizer Model/Series IZS4 Series Contents Safety Instructions . 1. How to Order . 1-1. Ionizer . 1-2. Accessories . 1-3. Option . 2. Installation . 2-1. Installation of ionizer . 2-1-1. Selection of piping port size . 2-1-2. Distance for installation . 2-1-3. Mounting and installation of the bracket . 2-2. Installation of the external sensor. 2-3.
LEF-D-2-1 For details, refer to the Web Catalog,) Note 4) Order auto switches separately. (For details, refer to the Web Catalog.)
870 1580 1570 1680 1710 1840 D-X Individual -X 221
LMV20/Without air blow circuit T0806 (8 x 6) Applicable tubing Symbol Length T0425 (4 x 2.5) Applicable tubing Air adjusting needle for mist T0604 (6 x 4) Applicable tubing Oil adjusting needle Mixing valve (LMV20-) LMV201 L 46 (24) Double pipe nozzle AIR OIL D C B 12 E A 24 9.5 2 3 57(Max.) 12.5 AIR SMC 27.5 4 10 40 23.5 OIL L Dimension (mm) 20 200 25 250 30 300 35 350 7.5 2 x 4.5 20 4
/ AC200V 2400/150 3200/220 4800/350 Ass'y XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 Ass'y 2 3 4 H5 AC100V 800/180 1200/300 1600/400 / AC200V 3200/180 4800/300 6400/400 1)/ 2)16 PTC() 200V 200 PTC 150 100V PTC Ass'y 0 5 10 15 20 25 30 Ass'y ( Ass'y 30 8 XL-OMV0002 4 4-1.162540 Assy SUS304 SUS316L ( SUS304) ( A6063) C D C E E (KF ) Fn J H B A G A mm A B C D E Fn G H J XLC
H 4 S y m b o l Initial power/ Power consumption (W) 100 VAC 600/150 800/220 1200/350 200 VAC 2400/150 3200/220 4800/350 Heater assembly number XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 No. of heater assemblies 2 pcs. 3 pcs. 4 pcs.
Reduced outgassing Resin materials eliminated Laser marking is employed for the model designation. o u d t g e 2 a c s u s d i Reduction of outgassing due to surface treatment e n o u d t g R e g a 1 c s u s d i e n R g All the external parts (made of aluminum alloy) such as the body and slide table are electroless nickel plated.
1.0 x8 M6 x 1.0 x10 12REA 50/63 0 -0.2 L NA 33 2-Rc, NPT, G 1/4 14 14 E(h8) E(h8) X D I 4-TC 14 14 Effective thread depth R 23 22 K W 23 25 2 4-M8 x 1.25 25 8-Q 14.5 C 0.1 + Effective thread depth 12 Effective thread depth R B S + Stroke 2 ZZ + Stroke Q x R S TC x R Model L 122 110 K 38 32 C 70 60 X ZZ NA E D B 72.2 58.2 I 70 60 W 12-REA63 12-REA50 100 86 66 53 30-0.033 69 55 M10 x 1.5 x
Fittings & Tubing Air Cylinders Rotary Actuators 0 L0.1 4 x MM Thread depth J 2 x P (Piping port) A G E H G B NN Effective thread length T (R) D X Mounting nut Width across flats C F N ZZ + Stroke S + Stroke W K N F I NA TT 6 T Model MM L K J I H G F E D C B A S NN NA 34 N R 12-REA25 12-REA32 12-REA40 8 46 32 26.4 2 13 7.5 20.5 8 10 70 15 M5 x 0.8 18.5 30 M26 x 1.5 111 10 8 60 32 33.6 2 16
The signal has to be converted by an A/D converter for pressure display or switch output. Current output signal is a current signal in the range of 4 to 20 [mA]. The signal is transformed into a voltage signal before being converted by a A/D converter for pressure display or switch output.
H 4 S y m b o l Initial power/ Power consumption (W) 100 VAC 600/150 800/220 1200/350 200 VAC 2400/150 3200/220 4800/350 Heater assembly number XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 No. of heater assemblies 2 pcs. 3 pcs. 4 pcs.
For D-P4DW, 40 to 63 are available. Only D-P4DW type is assembled at the time of shipment. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) J79CN Since there are other applicable auto switches than listed, refer to page 18 for details.