SMC Corporation of America
Elite Part Number Search
Search Results "CDLA2B100-300-P"

0.025 MXS2540 MXS2550 0.04 0.03 MXS2550 MXS2540 0.020 0.03 MXS2530 0.02 0.015 MXS2530 MXS2520 MXS2510 MXS2520 MXS2510 0.02 0.010 0.01 0.01 0.005 0 100 200 300 400 0 100 200 300 400 50 100 150 200 250 300 0 Load N 1N = 0.2248 lbf Load N 1N = 0.2248 lbf Load N 1N = 0.2248 lbf 50 Air Slide Table MXS Series Option Specifications Dimensions of Stroke Adjuster at Extension End (mm) Adjustable

Bore size (mm) Maximum stroke Standard stroke (mm) 32 700 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 40 800 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80 1400 25, 50, 75, 100, 125, 150, 175

L1 L2 5 P = 19 14 24.5 (mounting holes) 49.5 11.5 8.5 2 18.5 R P R P 11.5 18 37 11.5 18 37 67.5 59 Max .10 71.5 Pg.7 Manual override (non-locking) 4Rc(PT) 1/8 (ports P, R) 18 25 31 53.5 Approx. 300 (lead wire length) Light (DZ type only) 4Rc(PT) 1/8 (ports P, R) 75.5 83 Manual override (non-locking) nRc(PT) 1/8 (port A) Applicable cord O.D. 4 to 6.5 A A P = 19 20 L: Dimension table n: Stations

M N 4-O T Q 2-P AH AG S K W U L B AL I 4-AK hole R AA AP J X AB A Y + Stroke V AI Z + Stroke AJ For 4-AO AG AN AI Cutout window 100 piston rod end connection AM Mounting dimensions For standard strokes (mm) Bore size (mm) Stroke range (mm) O N M L K J I B AP AO AN AM AL AK AJ AI AH AG AB AA P A 75, 100 125, 150 200, 250 300 63 80 100 M12 x 1.75 depth 23 100 66 180 135 117 65 228 60 M12 234

L1 L2 5 P = 19 14 24.5 (mounting holes) 49.5 11.5 8.5 2 18.5 R P R P 11.5 18 37 11.5 18 37 67.5 59 Max .10 71.5 Pg.7 Manual override (non-locking) 4Rc(PT) 1/8 (ports P, R) 18 25 31 53.5 Approx. 300 (lead wire length) Light (DZ type only) 4Rc(PT) 1/8 (ports P, R) 75.5 83 Manual override (non-locking) nRc(PT) 1/8 (port A) Applicable cord O.D. 4 to 6.5 A A P = 19 20 L: Dimension table n: Stations

Up to 300 Up to 300 25 Without rod boot With rod boot Bore size (mm) H1 NA P PG PH PL PW S TA TB TC l H ZZ e f h ZZ Stroke range Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/8 33 38 39 44 55 62 62 70 19.5 24 24 24 16 17 17 17 20 24 24 24 30 30 35 35 38 41 41 41 178 193 196 221 141 151 154 169 35 40 40 50 Up to 200 Up to 300 Up to 300 Up to 300 11 11 11 12 5 6 6 8 11 11 10 10 24 29 36 44 M5 x 0.8 M6 x 0.75

P.5-13 (14) Startup operation status display Displays the status of operation settings at startup P.5-14 (15) Anti-freezing status display Displays the status of anti-freezing settings. P.5-14 (16) Warming up status display Displays the status of the warm-up settings. P.5-14 Pump operation continuation status display Displays the status of pump operation continuation setting.

P #Vacuum Ejector or Pump and Number of Vacuum Pads Ejector and number of pads Vacuum pump and number of pads Vacuum line Tank P P P P P P P P P Ideally, one pad should be used for each line. When more than one pad is attached to a single vacuum line, take the countermeasures listed below.

VK300 Grommet: G DIN terminal: D Applicable cable O.D: 3.5 to 7 (Mounting hole) Manual override (Non-locking) n1-Rc 1/8 (A port) 300 4-Rc 1/8 (P , R port) 4-Rc 1/8 (P , R port) (Lead wire length) (Mounting hole) (Pitch) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

MXS2550 0.025 0.04 0.03 MXS2550 MXS2540 0.020 0.03 MXS2530 0.02 0.015 MXS2530 MXS2520 MXS2510 MXS2520 MXS2510 0.02 0.010 0.01 0.01 0.005 0 100 200 300 400 0 100 200 300 400 0 50 100 150 200 250 300 Load (N) Load (N) Load (N) D-X Individual -X 57 Series MXS Dimensions: MXS6 Basic style 2 x M2.5 x 0.45 thread depth 3 Operating port 2 x M3 x 0.5 6 J I Max. 10.5 (With stroke adjuster at retraction

E N S I O N S A I R P I L O T O P E R AT E D T Y P E (N)VBA2200-03, (N)VBA4200-04 mm Model Port Size A B C D E F G H J K L (N)VBA2200-(N)03 38 300 126.5 53 118 98 44 45 60.5 18 15 (N)VBA4200-(N)04 12 404 167 96 150 130 62.8 62 90 17 15 40 Courtesy of Steven Engineering, Inc. !

100 200 300 400 500 600 V(mm/s) 0 100 200 300 400 500 600 V(mm/s) 0 0 100 200 300 400 500 600 V (mm/s) LEFS 16 LEFS 25 LEFS 32 50 12 20 W(kg) W(kg) 10 W(kg) W(kg) W(kg) W(kg) 6 40 6 15 8 30 8 6 8 10 5 5 20 4 5 12 10 16 10 12 16 10 2 0 0 0 0 100 200 300 400 500 600 V (mm/s) 0 100 200 300 400 500 600 V(mm/s) 0 100 200 300 400 500 600 V(mm/s) -9- (1)(DC24V) LEFS40 (mm) 1) 200,

SYJ7000-21-1A 1 pc. 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 3 position exhaust center 3 position closed center (A) 4 (A) 4 (B) 2 (B) 2 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) The asterisk denotes the symbol for assembly.

Select "P-1". U UP P D DO OW WN N b. When the "UP" and "DOWN" buttons on the driver operation are pressed, the display will be shifted as shown below, Select "P-3" and press the "SET" button. Point table No.1 No.2 No.3 No.4 No.5 No.6 No.7 c. The "UP" and "DOWN" buttons on the driver operation are pressed to Select "Spd", thenpress the "SET" button.

P1 Control Circuit Power Supply Connector: CNP2 Accessory P2 Terminal name Function Function details P P C D Connect between P and D. (Connected at time of shipping.) If regeneration option is required for Model Selection, connect to this terminal.

ZP3E 300 g 300 x 9.8/1000 = 2.94 N N = (9.8 x W/1000)/(F) = (9.8 x 9700/1000)/(11.2) = 9 Rounding up to the nearest higher integer ZP2 For a workpiece mass of 300 g (2.94 N) XT661-6A: Temporary lifting force 2.95 N Workpiece mass 300 g (2.94 N) XT661-8A: Temporary lifting force 3.75 N Workpiece mass 300 g (2.94 N) XT661-10A: Temporary lifting force 7.2 N Workpiece mass 300 g (2.94 N)

(Values at the initial period) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 3 position pressure center (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 3-10-7 8 Series VQ7-6 DIN Terminal Type 2 position single : VQ7-6-FG-S single (Reverse pressure): VQ7-6-YZ-S 120.5 120.5 68.5 52 68.5 Mounting hole 2-6.5 50 50 42.5 42.5 25 25 13 (A port) 13 (B port) Manual override (R1, R2) 2-3/8 P R2 R1 A B 14 11 50 62 12 9 62

(Values at the initial period) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 3 position pressure center (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 3-10-7 Series VQ7-6 DIN Terminal Type 2 position single : VQ7-6-FG-S single (Reverse pressure): VQ7-6-YZ-S 120.5 120.5 68.5 52 68.5 Mounting hole 2-6.5 50 50 42.5 42.5 25 25 13 (A port) 13 (B port) Manual override (R1, R2) 2-3/8 P R2 R1 A B 14 11 50 62 12 9 62

PI Control Level 1 P control 4 Switches the speed control from PI control to P control.

The PC or PLC...etc may not be able to monitor a brief change in the P-OT or N-OT signal to P-OT=1 or N-OT=1.