A: Lock unit holding bolt R 075 CKQG32X B 08 CKQG32X CK1 B: Cylinder holding bolt Guide pin diameter * Refer to Table 1 (Symbol 2) below. Applicable hole diameter of workpiece * Refer to Table 1 (Symbol 1) below.
Round plate (Including column) Position of rotational axis: Through the center A axis B Number of teetha 1. Find the moment of inertia I for the rotation of shaft (B). B 2. I is converted to the rotation of the shaft (A). r B 2 r I = m2 2 b a I I = A B Number of teethb 5.
Solid state auto switch: D-M9B, D-M9N B E Model Auto switch operating range Stroke Stroke A 40 50 150 100 75 100 10 20 30 125 75 20 30 125 150 10 40 50 13-/22-MXS6 0.4 0.4 0.4 11.6 17.5 9.6 9.6 9.6 21.6 27.6 1.5 10 13-/22-MXS8 4.9 0.1 0.9 8.9 16.9 41.9 14.9 9.9 10.9 18.9 26.9 51.9 1.5 11.6 13-/22-MXS12 74.4 32.4 22.4 12.4 14.4 24.4 22.4 12.4 2.4 4.4 14.4 35.4 64.4 2.5 45.4 15.6 13-/22
MY1CW16/20 MY1MW16/20 B A Reed Switch Solid State Switch D-A90(V), D-A93(V), D-A96(V) (mm) D-M9N(V), D-M9P(V), D-M9B(V) D-F9NW(V), D-F9PW(V), D-F9BW(V) 16 20 Mounting position Mounting position 16 20 A A B B Operating range Note) Operating range Note) Solid State Switch Reed Switch 24 Series MY1W Mounting of Auto Switch & Installation of Lead Wire Cover (50, 63) Caution Be sure to install
Rotary Actuator Vane Type CRB2 Series Size: 10, 15, 20, 30, 40 RoHS How to Order B S E 20 180 S Z CRB2 u Z L M9B CDRB2 B W 20 180 S With auto switch q r e !1 i o !
Applicable cylinder MY3A16, MY3B16 MY3A25, MY3B25 MY3A40, MY3B40 MY3A63, MY3B63 A B A B A B A B MY-S16 MY-S25 MY-S32 MY-S40 63.6 Data 091 130 182 Guide for Using Side Support For long stroke operation, the cylinder tube may be deflected depending on its own weight and the load weight.
In the case of mounting auto switch from B direction Step 2) Insert the auto switch into the auto switch installation groove from direction B. A B MHZ MHF Step 3) Slide the auto switch in the direction of the arrow until the indicator light illuminates.
Insert the switch into the switch case, and install switch holder B into the first groove (MRHQ20/25) or the second groove (MRHQ10/16) and secure the switch.
A B A B 54 MXY6 34 MXH 59 5 MXY8 39 MXU 67 MXY12 47 MXS Solid State Auto Switch D-M9B(V), D-M9N(V), D-M9P(V) Lead wire entries inside MXQ (mm) B B Model Mounting Auto switch operating range MXF A B A B A B 50 MXY6 3 38 MXW 55 MXY8 3.5 43 MXJ 63 MXY12 3 51 MXP Lead wire entries parallel 2-Color Display Solid State Auto Switch D-M9BW(V), D-M9NW(V), D-M9PW MXY (mm) B A Model Mounting Auto switch
A B A B 54 MXY6 34 59 5 MXY8 MX 39 67 MXY12 MTS 47 MY Solid State Switch D-M9B(V), D-M9N(V), D-M9P(V) Lead wire entries inside (mm) B B CY Model Mounting Switch operating range A B A B A B 50 MXY6 2 MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 38 55 MXY8 2.5
8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433: *2) 1. 2. 3. 1. 2. 3. 4.
Calculate the moment of inertia for A and B separately as shown in the figures on the right. A part B part Procedure Calculation Calculation example 1. Check the operating conditions, dimensions of attachment, etc. Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.
Round plate (Including column) Position of rotational axis: Through the center axis (B) Number of teetha 1. Find the moment of inertia I for the rotation of shaft (B). B r 2. I is converted to the rotation of the shaft (A). B 2 r I = m2 2 b a I I = A B Number of teethb 5.
Solid state switch D-F8 CUJ (As compared with SMC Series CU cylinders without magnet) Dimensions (Without magnet) Series Variations Bore size (mm) A(a) B(b) C(c) Bore size (mm) Rod end configuration Stroke (mm) Clean series 4 6 8 10 15 20 b Action Series Auto switch B Double acting Male thread Without thread None 4 10() 15() 13() 4 Single acting, Spring return 6 13(13) 19(22) 13(33) Double
Inversion Traveling direction of cylinder Rod extending Rod retracting A-phase pulse B-phase pulse Count In rod extending direction, A-phase turns on first, then B-phase turns on with the delay of approximately 90 phase difference. In rod retracting direction, B-phase turns on first, then A-phase turns on with the delay of approximately 90 phase difference.
30 40 13 XL-OMY0002 8 X L D 25 M9N A A ( X A N1 A ) 25 40 B A 50 63 80 C P11 160 100 FKM() P8 KF (NW) D K (DN) () A / A F G A J B K C L M M9N D-M9N M9P D-M9P / 560 M9B D-M9B A90 D-A90 H0 H4 H5 5150 100 A93 D-A93 120 M9// 25H4 14 XL-OMY0002 9. 200 2580 100 100,160 [] 1 1.5 1 XLD-25,XLD-40,XLD-50,XLD-63,XLD-80 200 XLD-100,XLD-160 100 : FKM 110 Pa <> 15 XL-OMY0002
Proper Auto Switch Mounting Position (Detection at stroke end) C D A B D-A9, D-A9V D-M9, D-M9V, D-M9W, D-M9WV B B Series model A Series model A Operating range Operating range MY2C16 MY2C16 44 116 48 112 MY2H16 MY2H16 46 114 50 110 MY2HT16 MY2HT16 11 8.5 70 90 74 86 MY2C/H/HT25 MY2C/H/HT25 54 156 58 152 MY2C/H/HT40 MY2C/H/HT40 85 245 89 241 Series model C Series model C D D Operating range
Proper Auto Switch Mounting Position (Detection at stroke end) C D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A B Series MY2C Series MY2H Series MY2HT (mm) D-M9, D-M9V (mm) D-M9, D-M9V (mm) D-M9, D-M9V A A A B B B Bore size 16 25 40 Operating range Bore size
A-phase pulse B-phase pulse 11 12 11 10 10 Count multiplier In rod extending direction, A-phase turns on first, then B-phase turns on with the delay of In rod retracting direction, B-phase turns on first, then A-phase turns on with the delay of approximately 90 phase difference. approximately 90 phase difference. Counter performs addition in and does subtraction in .
Rack & Pinion Type Rotary Actuator Series 11-CRA1-Z Size: 30, 50 RoHS How to Order 11 Vacuum suction type Clean series Nil Auto switch No D Built-in magnet B Mounting Basic L Foot Shaft type S Single shaft W Double shaft 30 Size 50 11 C D R A 1 B S 50 90 Z M9B Rotating angle Number of auto switches 90 180 100 90 180 100 190 Nil S 2 pcs. 1 pc. 190 Type of auto switch (For model with auto switch