SMC Corporation of America
Elite Part Number Search
Search Results "AWD20-F01BE-6-D"

W Mounting: Basic, Flange, Foot (mm) Auto switch model D-A90 D-A96 D-A9V D-M9 D-M9W D-M9V D-M9WV D-A93 Bore size W 4 6 4 6 6 4 2 4.5 10 2.5 0.5 0 1 16 2.5 0.5 0 1 Mounting: Clevis, Trunnion (mm) Auto switch model D-M9V D-M9WV D-A9 D-A9V D-M9 D-M9W DBore size W 4 -X 6 1 0 10 0 0 Individual -X 16 0 0 0 (zero) denotes the switch does not protrude from the end surface.

to 25 6 to 25 10/16 15/32 Bore size 610 6 D-C7/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8 D-A7H/A80H D-A73C/A80C D-A79W D-A5/A6 D-A59W D-A9 D-A9V D-Z7/Z8 D-H7 D-H7C D-H7BAL D-H7F D-H7W D-G5/K5 D-G5BAL D-G59F D-G5NTL D-G5W/K59W D-G39/K39 D-G39A/K39A D-F7/J7 D-J79C D-F7F D-F7BAL D-F7BAVL D-F7V D-F7NTL D-F7W (V) D-F5/J5 D-F5BAL D-F5W/J59W D-F5F D-F5NTL D-G39C/K39C D-M9

VX22 0 5 6 VX23 0 5 6 VX070-029 4.1-3 VX21/22/23 Energized Closed (N.O.)

B A A B 1 Chromic acid (25%, 70C) B D D A A B 2 Boric acid Inorganic salt B D A A B A 3 Sulphuric acid (30%, Room temperature) D D A A B A 4 Phosphoric acid (50%, Room temperature) D A A B B A 5 Ammonium hydroxide B A A B B D 6 Sodium hydroxide (30%, Room temperature) Inorganic alkali A D C D A A 7 Calcium hydroxide A D A A C A 8 Magnesium hydroxide A B A A B A 9 Acetylene A A A A A A 10

Model A L D KQ2P-04 KQ2P-06 KQ2P-08 4 6 32 16 6 8 35 18 8 10 39 20.5 A A A A A B B 5 Series SZ3000 DIN rail dimension table/weight table D-sub connector (25 pins)/cable assembly VZ1000-11-11 VVZS3000-21A~ 3 Refer to the L dimension table Enter a number from the DIN rail dimension table below in the .

XAH7 depth 6 WB Q GB 37.5 + Stroke C + Stroke WA 17 J K S 2-Rc 1/8 (plug) 6 XAH7 depth 6 10 HR G E B + Stroke A + Stroke 2-Rc 1/8 With front lock XB XAH7 15 8.4 5.4 HN d e 4.5 3 6 XAH7 24 End lock mechanism (Locking type manual release) T-slot dimensions 24 (mm) Section XX detail Bore size (mm) d e 15 For 25 2.8 7.8 20 DM 3 8.2 25 With rear lock Refer to "Manufacture of Intermediate Strokes

Series VQC2000 4 5 6 7 Base-Mounted plug-in e Electrical entry/Cable length q Stations i Options 01 Nil None 1 station D-side entry Kit, Cable length Stations Note 2) All stations with back pressure check valve Note 1) B D D FD0 FD1 FD2 FD3 PD0 PD1 PD2 PD3 PDC TD0 D-sub connector kit (25P) without cable D-sub connector kit (25P) with 1.5m cable D-sub connector kit (25P) with 3.0m cable

: (800) 258-9200-www.stevenengineering.com D-M9 D-F9W D-M9V D-F9WV D-F9BAL D-A9 D-A9V D-M9V, D-F9WV Auto switch model D-M9, D-F9W W A A 0 B B 17 Hs 5.5 A B 5.5 W 5.5 A 4.5 B 19 Hs Symbol 12 1.5 1.5 1.5 (4) 0 4.5 16 2 2 2 (4.5) 0 0 19 6 4 6 6 4 21 Bore size (mm) 20 6 6 1.5 (1) 3.5 3.5 22.5 10 7.5 2.5 10 7.5 24.5 25 7 7 3.5 (1) 5.5 5.5 24.5 11 9.5 0.5 11 9.5 26.5 ( ): Denotes the values of

B A A B 1 Chromic acid (25%, 70C) B D D A A B 2 Boric acid Inorganic salt B D A A B A 3 Sulfuric acid (30%, Room temperature) D D A A B A 4 Phosphoric acid (50%, Room temperature) D A A B B A 5 Ammonium hydroxide B A A B B D 6 Sodium hydroxide (30%, Room temperature) Inorganic alkali A D C D A A 7 Calcium hydroxide A A A D C A 8 Magnesium hydroxide A A A B B A 9 Acetylene A A A A A A 10

Note 2) 2 magnets for auto switches are installed in the housing. 8-26-49 48 Series CXWL Operating Range (mm) Auto switch model Applicable cylinder size 10 16 20 25 32 Housing mounting D-A7/A80 D-A7H/A80H D-A73C/A80C 6 6 6 6 Plate mounting 6 D-E7A/E80A 6 Housing mounting D-F7/J79 D-F7V/J79C D-F7W/F7WV D-F7BAL/F7BAVL D-F79F, D-F7NTL Housing mounting 4 4 3.5 3.5 Plate mounting 3 2.5 2.5

1 y u i D-M9m !6 Component Parts No. Description Material No.

47 C 11 21 27 34.5 35.5 44.5 A 19.5 29.5 35.5 43 44 53 6 10 15 20 25 32 Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.

Minimum Stroke for Auto Switch Mounting (mm) No. of auto switches mounted 2 Different sides Auto switch model Same side n Different sides 1 Same side D-C7 D-C80 15 50 + 45 (n 2) 50 10 n 2 2 15 + 45 ( ) (n = 2, 4, 6) D-H7 D-H7W D-H7BAL D-H7NF 15 60 + 45 (n 2) 60 10 D-C73C D-C80C D-H7C n 2 2 15 + 50 ( ) (n = 2, 4, 6) 65 + 50 (n 2) 15 65 10 n 2 2 D-B5 D-B64 15 + 50 ( ) (n = 2, 4, 6) 15

:t ; : ; = '6;; 6 < EI 6 < EI d-z E < 8i E < ' 6 2 'dz 'Eiz 6 Z ,n2 < 2 6 V < 2 6 Y a z 6 Y d t d 2 45 90 PSI (3 ^ 6 kg cm'?) o.17 0.004/ 0,025/ o.17 ).00410.025 5 c/s 40 120"F (5 50.C) I I I (PV) . (PSePD) (PVe)PSePD) ' Provided as standard: l\Iounting bracket t See p 28 & 29 also.

Inspection before daily operation D Inspection every 6 months/1000 km/ 5 million cycles D D D AC Servo Motor Specific Product Select whichever comes sooner. Body fixed A # Items for visual appearance check 1. Loose set screws, Abnormal dirt 2. Check of flaw and cable joint 3.

How to order applicable valves Stations VQ 5 1 0 0 Y 5 7 B W D side 3 2 4 6 1 5 Note) Stations are counted starting from station 1 on the D side. Body type 4.

:t ; : ; = '6;; 6 < EI 6 < EI d-z E < 8i E < ' 6 2 'dz 'Eiz 6 Z ,n2 < 2 6 V < 2 6 Y a z 6 Y d t d 2 45 90 PSI (3 ^ 6 kg cm'?) o.17 0.004/ 0,025/ o.17 ).00410.025 5 c/s 40 120"F (5 50.C) I I I (PV) . (PSePD) (PVe)PSePD) ' Provided as standard: l\Iounting bracket t See p 28 & 29 also.

Blank plug Dimensions 23 04 06 KQP-X19 A L D Model Fittings size d Color: White 3.2 4 6 16 16 18 3.2 6 8 31.5 32 35 KQP-23-X19 KQP-04-X19 KQP-06-X19 It is inserted into an unused cylinder port and SUP/ EXH ports. The minimum order quantity is 10 pcs.

Tightening Torque 6 8 12 16 20 25 D-A9/A9V D-M9/M9V D-F9W/F9WV 4.5 5 6 7 8 9 2 (2.5) 2.5 (2.5) 3 (3) 4 (3) 6 (3.5) 6 (3.5) Use a torque of approximately 0.05 to 0.1 Nm. As a guide, it can be tightened about 90 past the position at which tightening can be felt. Note) Figures in parentheses are the cases for D-M9, D-M9V switch types.

Ejector mounting position ZZYX3 45T U side D side U D J Mounting position of connector Number of ejectors 1 to 3 stations A, B port size (Valve only) U side D side U D C4 C6 4 One-touch fitting 6 One-touch fitting Mixed M SUP/EXH block assembly mounting position Total number of ejector/valve stations U D side D B U side When creating the mixed specifications, complete the stations table on