VR 2-M5 x 0.8 depth 7 (Mounting screw) VH VHS Dimensions/Manifold VVTA300-1 VVTA300-3 (Pitch) Max. 2 Max. 2 Pilot port Pilot port 4-M4 (Mounting hole) (Mounting hole) 4-M4 (P port) (Pitch) (P , R port) (R port) (A port) (A port) Individual Exhaust Common Exhaust n n: Station n n: Station 2 76 64 3 102 90 4 128 116 5 154 142 6 180 168 7 206 194 8 232 220 9 258 246 10 284 272 2 88 62 3 114
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
A Three Way Valve or a Two Way Normally Open Valve is dead ending (no flow when energized) for repetitive cycles that have an On Time greater than 1 1/2 hours. 6. A Three Way Valve or a Two Way Normally Open Valve is being used with media of excessive temperature. 7. A combination of the above-consult factory on any questionable applications.
hole for 2-M5 B A B A A A B A B A B A 9 A A A A A A A 143 163 42 80 34.5 R4.5 B B 9 B B B 55.5 SI unit 10 101 Stations D-side U-side 1 2 3 4 5 6 7 8 n Formulas L1 = 25n + 106 (Maximum 16 single wiring stations) L2 = 25n + 192 n: Stations n L L1 L2 1 131 217 2 156 242 3 181 267 4 206 292 5 231 317 6 256 342 7 281 367 8 306 392 9 331 417 10 356 442 11 381 467 12 406 492 13 431 517 14 456 542
B A B A B A B A B A B A B A B A B 40 50 63 80 100 6 4 3.5 1.5 0 0.5 6.5 2 4 11.5 10 0 0 4.5 0 2 9.5 8 ML2B 3.5 1.5 0 0.5 6.5 2 4 11.5 10 0 0 4.5 0 2 9.5 8 8.5 7.5 6 5 2.5 3 9 4.5 6.5 14 12.5 1.5 2 8 3.5 5.5 13 11.5 12 10 9.5 7.5 6 6.5 4.5 8 10 17.5 16 4 4.5 12.5 6 8 15.5 14 13.5 12.5 11 10 7.5 8 14 9.5 11.5 19 17.5 6.5 7 13 8.5 10.5 18 16.5 D-A9 and D-A9V cannot be mounted on 50.
Storage of data other than the request message to store When a parameter is changed with a key-in operation, the product stores all parameters into the EEPROM even if not receiving a request message to store. 3-6 HEF002-A6 Communication Format 3.7 Communication Example Communication example of request message to read Request message from master: Request the product having a set address of
Storage of data other than the request message to store When a parameter is changed with a key-in operation, the product stores all parameters into the EEPROM even if not receiving a request message to store. 3-6 INR-244-831 Communication Format 3.7 Communication Example Communication example of request message to read Request message from master: Request the product having a set address
20 27.2 13 T T A A Width across flats H Width across flats 22 H Width across flats A T Connection male threads T Connection male threads Effective area mm Min. bore Weight g Model Effective area mm Min. bore Weight g Model A L L 41.5 R 1/8 30 R 1/8 81 18 45.5 34 19.0 6 6 22.6 KK13P-01M KK13S-01M 14 42.5 R 1/4 31 R 1/4 86 22 24.1 7 -02M -02M 48.5 37 42.1 R 3/8 30.6 R 3/8 89 7.5 35.3 27 31.1
3 position exhaust center: VZA4441--01 02 Pilot port (B side) Body side 2-4.5 Mounting hole Pilot port (A side) 2-M5 x 0.8 body side Pilot port (A side) 2-M5 x 0.8 sub-plate side (R1, R2 port) (P , A, B port) Pilot port (B side) Sub-plate side 5-3-8
Valve model Port size VCS21 VCW20-12-01A 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCW30-12-02A 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCS31 VCW30-12-04A Note 1) 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-02A 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCW30-12-04A Note 1) 1/2 VCS41 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-06A 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 2 mounting screws (for mounting bracket
~~ , A 00) 0(0) 0 (2.5) 2(6) 4(7. 5) ~ , 40 D-AG 43.5 49 55.5 3 D-AS 1(0 1(0) 5(1.5 I O{S.5) 8(4 3t 35 42 so 57 .5 ~ Ht A 00) 00) 0(2.5 26 417 .5) D-A3 B !
[Check valve] A check valve is a safety device intended to prevent reverse flow. The AP 64 is a unique design with only one moving part in the gas stream, an O-ring. It is a springless design, free of springs and poppets. [Vacuum generator] A venturi device that creates vacuum by flowing gas through a nozzle.
Distributor Series VA, VB How to Order V A 4 6 Applicable tube O.D. 6 6 Oil Distributor Number of distribution ports (VA) (VB) VB6-6 Distribution 4 ports 6 ports 8 ports 4 ports 6 ports 10 ports 16 ports 4 6 8 4 6 10 16 Both sides exhaust One side exhaust A B VA4-6 Dimensions VAl-6 VBl-6 A B C Model # Ports Applicable tubing 4 6 10 16 36.5 60 88 130 VA4-6 VA6-6 VA10-6 VA16-6 Model # Ports
Since a large quantity of liquid will be pumped out, use a suitable throttle in the discharge port if problems occur. Note 3) With a low number of operating cycles, even a valve with a small Cv factor can be operated.
Since a large quantity of liquid will be pumped out, use a suitable throttle in the discharge port if problems occur. Note 3) With a low number of operating cycles, even a valve with a small Cv factor can be operated.
The dual type speed controller is especially suitable for cylinders with a small bore size. Elbow/Universal Type Air Flow/Effective Area Model AS121FM-M5 AS131FM-M5 AS221FM-01 AS231FM-01 AS221FM-02 AS231FM-02 RE A B 3.2, 4, 6 3.2, 4 6, 8 4 6 8, 10 Metric size Tubing O.D.
The dual type speed controller is especially suitable for cylinders with a small bore size. Elbow/Universal Type Air Flow/Effective Area Model AS121FM-M5 AS131FM-M5 AS221FM-01 AS231FM-01 AS221FM-02 AS231FM-02 RE A B 3.2, 4, 6 3.2, 4 6, 8 4 6 8, 10 Metric size Tubing O.D.