T) V 1 2 1 2 1 2 1 2 LVQ3 , LVQ4 LVQ5 , LVQ6 N M V A B U B A Z (Max.
Please consult with SMC if you use a fluid other than compressed air. 2. A protective cover is recommended to minimize the risk of personal injury. If a driven object and moving parts of a cylinder are in close proximity, personal injury may occur. Design the structure to avoid contact with the human body. 2.
(A) 2 (A) 2 1 (P) 3 (R) 1 (P) 3 (R) q w e r q w e r N.O. N.O. (A) 2 (A) 2 1 (P) 3 (R) 1 (P) 3 (R) Component Parts No.
39 0D 01 32 02 32 32 35 30 32 03 32 3F 0D Answer 25.02 deg.C 33 Reading external sensor 2 01 32 05 33 36 3A 0D 01 32 02 33 33 30 30 32 03 32 3C 0D Answer 30.02 deg.C 34 Reading alarm status 2 01 32 05 34 36 3B 0D 01 32 02 34 30 38 30 03 30 30 0D Answer ERR11 Answer -1.52 deg.C Reading offset 01 32 05 36 36 3D 0D 01 32 02 36 2D 31 35 32 03 32 3F 0D 2 36 Offset setting (without writing EEPROM
Note 1) Same as standard product except for cover assembly Note 2) 03, 04, and 06 indicate the relevant port sizes (Rc3/8, 1/2, 3/4). 108 108 AIR VENT M6 x P1 G1/2 AIR VENT M6 x P1 2 x RcD 2 x RcD C B A B OUT IN OUT IN C A DRAIN G1/4 DRAIN G1/4 (mm) (mm) A B D C A B D C Model Element length Model Element length A (L250) A (L250) 314 70 374 314 70 407 FGDC FGDE FGDC FGDE B (L500) B (L500)
Nijverheidsstraat 20 B-2160 Wommelgem Belguim TEL: 03-355-1464 FAX: 03-355-1466 TAIWAN SMC Pneumatics (Taiwan) Co.,Ltd. 17, Lane 205, Nansan Rd., Sec.2, Luzhu-Hsiang, Taoyuan-Hsien, TAIWAN TEL: 03-322-3443 FAX: 03-322-3387 POLAND SMC Industrial Automation Polska Sp.z.o.o. ul.
IDG50<A 291 269 361 302 1/4, 3/8 330 308 400 341 IDG60< 330 352 369 428 IDG75<, 100< IDG60<A 326 348 367 426 3/8, 1/2 1/2 IDG75<A 396 418 436 495 3/8, 1/2 IDG100<A 461 483 501 560 13 RoHS Membrane Air Dryer/Unit Type Series IDG<A Reduced purge IDG<A Series Type M, Type V How to Order Reduced M 3 A IDG 03 30 purge IDG<A Series Made to Order Refer to page 33 to 44 for details.
Note 2) Including O-Ring. Contact P/A regarding the bowl assembly supply for PSI and F unit specifications.
A-type mounting bracket YA-03 YA-05 B-type mounting bracket YB-03 YB-05 32, 40 50, 63 YU-03 YU-05 RS M W T2 V K (Width across flats ) H (With locking) Material: Carbon steel (Nickel plated) (mm) 2 x D through 2 x O counterbore T1 B E J d1 d2 Bore size (mm) B D E J M O Part no.
PORT SIZE APPLICABLE ISO SIZE 02 1/4" 1 CODE A, B, PORT SIZE / LOCATION APPLICABLE ISO SIZE NOTES 03 3/8" 1, 2 02 1/4" SIDE ONLY 1 NO PORTS ON BOTTOM OF MANIFOLD 04 1/2" 1, 2, 3 03 3/8" SIDE ONLY 1, 2 06 3/4" 2, 3 10 1" 3 04 1/2" SIDE ONLY 1, 2, 3 02B 1/4" BOTTOM 2, 3 SIDE PORTS PLUGGED 03B 3/8" BOTTOM 1, 2 02S 1/4" SIDE 1 03S 3/8 SIDE 1, 2 BOTTOM PORTS PLUGGED HOW TO ORDER LATERAL PLUG-IN
Application 0 1 2 size Symbol IR1000 IR2000 IR3000 Made to Order Specifications (Refer to page 560) 01 02 03 04 1/8 1/4 3/8 1/2 Note) Air operated type is model IR3120 only.
Type A mounting bracket YA-03 Joint YU-03 Type B Mounting Bracket RS Joint/Mounting Bracket (Type A/B)/Part No.
Nijverheidsstraat 20 B-2160 Wommelgem Belguim TEL: 03-355-1464 FAX: 03-355-1466 TAIWAN SMC Pneumatics (Taiwan) Co.,Ltd. 17, Lane 205, Nansan Rd., Sec.2, Luzhu-Hsiang, Taoyuan-Hsien, TAIWAN TEL: 03-322-3443 FAX: 03-322-3387 POLAND SMC Industrial Automation Polska Sp.z.o.o. ul.
A type mounting bracket part No.YA-03 Joint YU-03 Joint Part No. Applicable mounting bracket Bore size (mm) Weight (g) Joint part No. B bracket A bracket YB-03 YU-03 YA-03 32, 40 25 YB-05 YU-05 YA-05 50, 63 40 Bore size (mm) YB-08 YU-08 YA-08 80 90 Part No.
144.5 143 112.5 83.5 179 46.8 59.2 106 9 9 U side 55.5 M5 ground screw 19 34.5 34 n 12 X 2n-Rc 3/8, 1/2 4(A), 2(B) port B 2 A 4 6 B 2 A 4 Indicator light 5 B 2 A 4 A 4 SMC SMC SMC SMC A A B B B B B Manual override L2 L1 58.5 P = 41 B 2 A 4 A B 3 B 2 A 4 A B 2 A 34.5 48 68.5 P = 41 B 2 A 4 A 1 A X 12 Stations R4.5 15.5 17 22 51 69 117 2-Rc 1/8 (External pilot port) 107.8 179 (Single, Double
-4.5 50 40 2-Port size Sensor unit Display unit (PF2W30/31) Brown 12 to 24 VDC 1 2 6 Analog output Main circuit Main circuit 4 8 2 Load + Switch output White (44.2) A 3 7 4 Black 1 5 3 Blue Load is an analog input equipment such as a voltmeter.
NPT thread Model Model 10-32 UNF M5 3/8 1/8 1/4 1/2 3/8 1/8 1/4 1/2 AKH04 AKH06 AKH08 AKH10 AKH12 AKH03 AKH07 AKH09 AKH11 AKH13 4 6 8 10 12 5/32 1/4 5/16 3/8 1/2 From One-touch fitting to male thread B Bushing type AKB 01 A 01 S With seal (Standard) Body size Port size 01 1/8 01 1/8 Thread type 02 1/4 02 1/4 03 3/8 Nil R 03 3/8 04 1/2 N NPT 04 1/2 Check valve free flow direction Female/Male
3/4" x 5/8" Class 1 2 1 2 1 2 3 1 2 1 2 1 2 A A B C A B A B A B A B 15A 20A 25A Note 1) For each piping diameter for each body size, the second and later numbers or symbols indicate reducing.
Connector pin numbers 2 1 (43.5) 4 3 A B Pin no. 1 2 3 4 Output specification Pin description DC(+) NC/Analog output DC() OUT A Pulse output only 42 62 52 Pulse output + Analog output 72 Flow direction 18 Series PF2W Dimensions: Remote Type Sensor Unit for Water PF2W511-(N)B 148 80 32 70 58 46 45 2-Port size 2 45 4-5.5 36 (43.5) A A B Output specification 63 Pulse output only 77 73 87 Pulse
(with flow adjustment valve) A: Total length of the supply unit (mm) Unit construction Flow range Port size A B C D E F Symbol Flow adjustment valve Stop valve Nil 31.9 127.9 (Max. 132.9) S 31.9 0.5 to 4 L/min 3/8 141.7 102.6 87.5 87.5 (symbol 04) (symbol 03) P 65.9 W 65.9 Nil 35.9 3/8 127.9 (Max. 132.9) S 35.9 2 to 16 L/min (symbol 03) 141.7 102.6 87.5 87.5 (symbol 20) 1/2 P 69.9 (symbol