(1) B2 53 64 76 Adjustable range A 65 82 98 Applicable bore size MY1B25 MY1B32 MY1B40 Note) One set of floating brackets consists of one right piece and one left piece.
A2 Blue 0 V IN B2 A3 Green F.G. Make sure to ground with a resistance of 100 or less to use it as a reference electric potential for Ionizer. Signal input to turn ON/OFF the ventilation with fan and ion generation. NPN specification: Ventilation and ion generation is stopped by connecting to 0 V.
Series CBA2 B port C port A port Atmospheric release port NCM Bore size (mm) ZZ S Q NCA B2 + Stroke S2 B1 + Stroke S1 40 230 168 53 A + Stroke (S1 + S2) 50 249 180 59 D63 268 196 61 80 320 232 73 -X Stroke B Stroke A 100 341 252 79 S + Stroke (A + B) Series MB The above diagram shows head side lock type and manual releasing nonlock type.
B2 OUT1 OUT1 Load Load B3 B3 OUT2 OUT2 Load Load B4 B4 OUT3 OUT3 Load Load B5 B5 OUT4 OUT4 Load Load B6 B6 OUT5 OUT5 Load Load B7 B7 BUSY BUSY Load Load B8 B8 AREA AREA Load Load B9 B9 SETON SETON Load Load B10 B10 INP INP Load Load B11 B11 SVRE SVRE ESTOP ESTOP Load Load B12 B12 ALARM ALARM Load Load B13 B13 Input Signal Output Signal Name Details COM+ COM Name Details OUT0 to OUT5 BUSY
B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 Dot color Dot mark Insulation color Connector pin No.
arrangement Socket connector pin arrangement Connections Connections 2-2-25 Base Mounted Series VQC VV5QC41 SA1 Kit (Serial transmission kit: EX500) 3(R) port 2-Rc 3/4 1(P) port 2-Rc 1/2 Communication connector C1 (M12 female thread) SMC SMC SMC SMC SMC SMC SMC 101 95.5 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 77.5 72 0 60 43.5 1 42.7 20.5 15.7 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A Communication connector C2
Allowable load Table 7 0.044mAllowable moment OK Moment of inertia Find inertial moment of load to calculate I=m(a2+b2)/12+m2 I=0.15(0.062+0.042)/12+0.150.032 energy. Find I.
E B1 B2 B3 L1 TG1 T l1 (Min.) l2 FL H (Max.) d1 d2 d3 CN SR (Max.)
Table for each pressure specification Applicable SMC pressure sensor Rated pressure range Display/set pressure range Display/min. setting unit PSE550 0 to 2 kPa -0.2 to to 2.1 kPa 0.001 kPa PSE531, PSE541, PSE561 0 to -101 kPa 10 to -105 kPa 0.1 kPa PSE533, PSE543, PSE563, PSE573 -100 to 100 kPa -105 to 105 kPa 0.1 kPa PSE532 0 to 100 kPa -10 to 105 kPa 0.1 kPa PSE564, PSE574 0 to 500 kPa
Cable specification Conductor area 0.15 mm2 (AWG26) Insulator Outside diameter 0.9 mm Sheath Finished outside diameter 4.8 Table for each pressure specification Applicable SMC pressure sensor Rated pressure range Display/set pressure range Display/min. setting unit PSE550 0 to 2 kPa -0.2 to to 2.1 kPa 0.001 kPa PSE531, PSE541, PSE561 0 to -101 kPa 10 to -105 kPa 0.1 kPa PSE533, PSE543, PSE563
B L1 W M2 B side Inch Size 6 4 Model A side B side B C1 C2 E1 E2 H1 H2 L1 L2 M1 M2 Min. port size W Applicable tubing O.D.
Auto switch mounting dimensions (mm) C3 A3 B1 Bore sizes 6, 10 0.4 0.3 0.4 0.3 7.2 4.8 7.2 4.8 C2 D2 Symbols Switch types D1 A2 B2 A A, A B B C C, C D D D-A9 C1 A1 D-F9, D-F9 D-A9 (Reed switch) D-F9, D-F9 (Solid state switch) D-A9V (Reed switch) D-F9V, D-F9V (Solid state switch) D-A9V D-F9V, D-F9V Auto Switch Mounting Caution Watchmakers screwdriver 1.
(1) B2 53 64 76 Adjustable range A 65 82 98 Applicable bore size MY1B25 MY1B32 MY1B40 Note) One set of floating brackets consists of one right piece and one left piece.
D-M9WV (mm) Mounting pattern q Note 2) Operating range Bore size Mounting patternq A1 Mounting patternw A2 Mounting patterne A3 B1 A1 B1 B2 B3 (mm) 10 15 25 5.5 34 64 22 76 34 76 5 35 70 23 82 35 82 5 40.5 99.5 28.5 111.5 40.5 111.5 Mounting pattern w B2 A2 Note 1) Adjust the auto switch after confirming the operating conditions in the actual setting.
K V 1 10 XLA S P1P2 XL XL Conductances combined When each of the separate conductances are given as C1, C2 and Cn, the composite conductance C is expressed as: C=1/(1/C1+1/C2++1/Cn) when in series, and C=C1+C2++Cn, when in parallel.
N'Y'VFS.1IDP-mT-2 Body type Plug-in type Non plug-in type ~~np NARBF3050-NO-Pl NARBF3050-NO-P2 =~A NARBF3050NO-Al NARBF3050-NOA2 =,. r lionS NARBF30SO-NO-B-l NARBF30SO-NO-B2 Body type Part No. Note) For pressure center type valves, use pin NARBF3000.
MY2H G D Za MY3A MY3B 4 x MM E1 E1 MY3M E4 E4 E3 E3 C E2 E2 F B G D Section Za detail (Adjustable range) Section Z detail (Adjustable range) Q P Zb JJ F B3 K B2 H B1 C1 Z B F A L 2 x 2 x LD Section Zb detail (Adjustable range) H A H A holding bolt (mm) B C D F G 90 H A Model MY-J50 MY-J63 Applicable bore size MY1B50 MY1B63 110 110 55 70 126 37 J C2 C 131 130 65 80 149 100 37 K L P Q E3 E4
/N.O.) u Coil type C2 C3 C4 C6 C8 Standard With power saving circuit (Continuous duty type) Nil T P P P Be sure to select the power saving circuit type when a valve is continuously energized for long periods of time. Note the specified energizing time when power saving circuit is selected.
(VJ3133) Air operated VJA3130 0.245 0.213 0.194 0.187 0.174 0.184 0.214 K2 K3 C1 C2 C3 C4 Weight includes Bracket B. (Solenoid valve: 24 VDC, M plug connector type) Air operated VJA3130 N.C. (VJ3133) N.C. (VJ3133) Double SOL. (VJ3233-X18) How to Order Refer to page 13-3-34 for further part no. information.
B1 B2 LVC DIN terminal: D Conduit terminal: T LVA LVH LVD LVQ J J 2-5.3 LQ NO P Port NO P Port LVN 2-5.3 Mounting hole H 35 H TI/ TIL F L L Cable 6 to 12 PA M 35 F D N (44) 34.5 PAX PB 25 C E C M G 1/2 K G 1/2 B1 3-Rc P E Bracket A 10.5 K B1 B2 Hexagon width across flats 22 A B1 N B2 3-Rc P B1 Bracket H J K L M L M L M L M N N Grommet Conduit DIN terminal Conduit terminal Electrical entry