Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, double rod, large bore, Bore size (mm): 125, 140, 160, 180, 200, Standard stroke (mm): 10 through 300, Port thread types: Rc, NPT, G, Auto switch capable, Compact Cylinder, NCQ2-Z, COMPACT CYLINDER, E38, 957.00000
Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, double rod, large bore, Bore size (mm): 125, 140, 160, 180, 200, Standard stroke (mm): 10 through 300, Port thread types: Rc, NPT, G, Auto switch capable, Compact Cylinder, NCQ2-Z, COMPACT CYLINDER, E38, 1276.20000
Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, double rod, large bore, Bore size (mm): 125, 140, 160, 180, 200, Standard stroke (mm): 10 through 300, Port thread types: Rc, NPT, G, Auto switch capable, Compact Cylinder, NCQ2-Z, COMPACT CYLINDER, E38, 844.60000
SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200
SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200
SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200
SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200
SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200
SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200
SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200
SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to +60°C, 5 port pilot operated valve, 4/5 PORT SOLENOID VALVE, 560 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to +60°C, 5 port pilot operated valve, 4/5 PORT SOLENOID VALVE, 1980 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to +60°C, 5 port pilot operated valve, 4/5 PORT SOLENOID VALVE, 2090 lb
Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or
Fluid: air/inert gas, Operating pressure range: 0.10 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 72.0 (4.0); 2 position rubber seal 79.2 (4.4) 3 position metal seal 41.4 (2.3) - 72.0 (4.0); 3 position rubber seal 45.0 (2.5) - 79.2 (4.4), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 20 or less to 62 or less; rubber seal 25 or
Fluid: air/inert gas, Operating pressure range: 0.10 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 72.0 (4.0); 2 position rubber seal 79.2 (4.4) 3 position metal seal 41.4 (2.3) - 72.0 (4.0); 3 position rubber seal 45.0 (2.5) - 79.2 (4.4), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 20 or less to 62 or less; rubber seal 25 or
Fluid: air/inert gas, Operating pressure range: 0.10 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 72.0 (4.0); 2 position rubber seal 79.2 (4.4) 3 position metal seal 41.4 (2.3) - 72.0 (4.0); 3 position rubber seal 45.0 (2.5) - 79.2 (4.4), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 20 or less to 62 or less; rubber seal 25 or
Fluid: air/inert gas, Operating pressure range: 0.10 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 72.0 (4.0); 2 position rubber seal 79.2 (4.4) 3 position metal seal 41.4 (2.3) - 72.0 (4.0); 3 position rubber seal 45.0 (2.5) - 79.2 (4.4), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 20 or less to 62 or less; rubber seal 25 or
Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient & fluid temperature: -10 to 50°C, 3 PORT BODY PORTED SOLENOID VALVE, 3 PORT SOLENOID VALVE, 24 lb