When the product repeatedly cycles with partial strokes, operate it at a full stroke at least once a day or every 1000 strokes. Otherwise, lubrication may run out. 3. Do not use the product in applications where excessive external force or impact force is applied to it. The product can be damaged. The components, including the motor, are manufactured to precise tolerances.
CN1IF(CONT) 18 - (LEC)(LEC) 5.4 CN2PC/TB (LEC)(LEC-T1-3*G*)(LEC-W2) CN2SWOFF(LEC)(LEC) (LEC-T1-3*G*)(LEC-W2) (1) CN2 (3m) (2) (USB) 120.3 120.3 mm mm 200 200 mm/s mm/s USB (A-miniB type) 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN2 () 9.
(Page 11) 7 1000 fR[N] 100 Lateral load applied to rod 100 80 63 10 50 40 1 0 500 1000 1500 Cylinder stroke [mm] Fig 1. Allowable lateral load applied to rod end C a u t i o n Be certain to align the rod axis with the load and direction of movement when connecting.
Val: -32766 to 32767 4 Scale upper limit setting 1 (UpLm/Scl) Val: 1000 Generates error per channel when the output value exceeds the set value. Disable Does not generate an error. Enable Generates an error. 2 User setting value lower limit error (Lwr_Lmt) Sets the scale lower limit.
Specification Seal cap EX9-AWTS For M12 connector socket: 10 pcs. -29No.EX-OMN0011-F Power supply connector (1) Cable with power supply connector Part number: EX500-AP0 1 0S Connector specifications S Straight A Angle Cable length (L) 1 1000 [mm] 5 5000 [mm] EX500-AP0#0-S EX500-AP0#0-A Item Specifications Pin No.
Specification Seal cap EX9-AWTS For M12 connector socket: 10 pcs. -35No.EX-OMO0030-E Power supply connector (1) Cable with power supply connector Part number: EX500-AP0 1 0S Connector specifications S Straight A Angle Cable length (L) 1 1000 [mm] 5 5000 [mm] EX500-AP0#0-S EX500-AP0#0-A Item Specifications Pin No.
Item Specifications Cable O.D. 7.7 mm Data pair 0.5 mm2/AWG20 Conductor nominal cross section Drain 0.34 mm2/AWG22 Wire diameter (Including insulator) 2.55 mm Min. bending radius (Fixed) 77 mm -30No.EX-OMP0005-I Power supply connector (1) Cable with power supply connector Part number: EX9-AC0 1 0-1 Cable length (L) 1 1000 [mm] 3 3000 [mm] 5 5000 [mm] Item Specifications Pin No.
cable specification> Cable: Shielded twisted pair cable (Type-A cable) Impedance 135 to 165 (3 to 20 MHz) Capacitance between conductors Less than 30 pF/m Conductor resistance 110 /km or less Wire diameter 0.64 mm or more Conductor area 0.34 mm2 or more Transmission speed and maximum cable length Transmission speed [kbps] 9.6 19.2 45.45 93.75 187.5 500 1500 12000 Cable length (m) 1200 1000
Enclosure IP40 Operating humidity Operation, Storage: 35 to 85% RH (No condensation) Environmental Withstand voltage 1000 VAC for 1 minute between terminals and housing resistance Insulation 50M or more between terminals and housing resistance (with 500 VDC megger) Temperature characteristics +/2%F.S.
Use this data as a guideline for selection, as the performance data may vary depending on the material and size of the work piece. 1) Discharge characteristics (Discharge time from 1000 V to 100 V) 2) Discharge characteristics range (Discharge time from 1000 V to 100 V) 25 2 Air flow scale: 1 Air flow scale: 2 1 20 3 Air flow scale: 3 Discharge time [s] 15 s 10 5 4 Air flow scale: 4 0 0 300
(Page 9) 6 Bushing (bearing) 1000 Lateral load applied to rod end {N} (fR)[N] 100 100 80 63 50 10 40 32 1 1900 0 500 1000 1500 Cylinder stroke [mm] Fig. 1 Allowable lateral load applied to rod end C a u t i o n Be certain to align the rod axis with the load and direction of movement when connecting.
Maximum stroke (mm) Basic Bracket Head side flange, Foot, Single clevis Rod side flange Double clevis Bore size Center trunnion 125 1000 or less 1600 or less 140 1000 or less 1600 or less 160 1200 or less 1600 or less 180 1200 or less 1569 or less 200 998 or less 250 813 or less 320 495 or less Note: Air cylinders with a 180 or more. have the stroke range falling within the scope of the second
.: 2 and 4) Max. load current 80 mA Max. impressed voltage 30 V (NPN output) Residual voltage 1 V or less (80 mA load current) Response time 2.5 ms (Chattering-proof function working: 20 ms, 160 ms, 640 ms, 1000 ms, 2000 ms selectable) Short circuit protection Provided Repeatability 0.5%F.S.
(Page 9) 6 Bushing (bearing) 1000 fR[N] 100 Lateral load applied to rod 100 80 63 10 50 end 40 1 0 500 1000 1500 Cylinder stroke [mm] Fig. 1 Allowable lateral load applied to rod end C a u t i o n Be certain to align the rod axis with the load and direction of movement when connecting.
Piston speed 80 to 500 mm/s 80 to 1000 mm/s 80 to 1500 mm/s Warning 1.
Enclosure IP65 Operating temperature range 0 to 50 oC (No freezing and condensation) Environment Operating humidity range Operation, Storage: 35 to 85% R.H. ( No condensation) Withstand voltage 1000 VAC, for 1 minute between the terminals and housing Insulation resistance 50 M min.
Specification Seal cap EX9-AWTS For M12 connector socket: 10 pcs. -41No.EX-OMP0013-E Power supply connector (1) Cable with power supply connector Part number: EX500-AP0 1 0S Connector specifications S Straight A Angle Cable length (L) 1 1000 [mm] 5 5000 [mm] EX500-AP0#0-S EX500-AP0#0-A Item Specifications Pin No.
0 are shipped as single units, a grease pack is included (10 g per 1000 strokes). Order with the following part number when only the grease pack is needed.
0 are shipped as single units, a grease pack is included (10 g per 1000 strokes). Order with the following part number when only the grease pack is needed.
Center Q1 = 0.019 + 0.040 + 0.019 + 0.040 = 0.118 L(ANR) End Center End Center Air consumed in the tubing is calculated using formula (2), as shown below. 0.5 0.1 Q2 = 12.6 x 1000 x x 10-6 = 0.063 L(ANR) An entire stroke includes two rotations from end to center where the air is consumed. Thus, the total air consumption Q of the rotary table and tubing is obtained as shown below.