Style: Pressure Switch w/ T-Spacer, Body Size: 40 (AC40), Thread Type: N (NPT), Port Size: 02 (1/4), Set Pressure Range: 0.1 to 0.4 MPa, Lead Wire Length: L (3m), Pressure Unit of the Scale Plate: MPa
Style: Pressure Switch w/ T-Spacer, Body Size: 40 (AC40), Thread Type: N (NPT), Port Size: 02 (1/4), Set Pressure Range: 0.1 to 0.4 MPa, Lead Wire Length: Z (5m), Pressure Unit of the Scale Plate: MPa
Style: Pressure Switch w/ T-Spacer, Body Size: 30 (AC30), Thread Type: F (G), Port Size: 02 (1/4), Set Pressure Range: 0.1 to 0.4 MPa, Lead Wire Length: 0.5m, Pressure Unit of the Scale Plate: MPa
Option 1 W Nil DIN Rail Mounting Bracket (Order Separately) With lead wire with connector (2 m) Connector cover (Silicone rubber) ZS 33 R With lead wire with connector (2 m) ZS-33-F S Stations ZS-33-D ZS-33-D S 1 2 3 4 5 1 station 2 stations 3 stations 4 stations 5 stations IN IN N Note) If an accessory is required, order separately using ZS part numbers.
Rod O.D.Applicable tubing O.D. 10 20 25 30 M5 standard 01 standard 02 standard 03 standard 04-04 06-06 08-08 10-10 4 4 6 6 8 8 10 10 wBring up the body, while holding it down. w eTake the finger off the release ring and remove the speed controller from the One-touch fitting. Control type Lock nut option Nil J Hexagon lock nut Round lock nut 0 1 Meter-out Meter-in Plug-in type 609
Supply pressure then ows to OUT1 q and partial exhaust from OUT2 takes place resulting in cylinder rod t movement to the right. The movement is linked via connecting rod r and feedback spring w to the input diaphragm e balancing the higher pressure. When this occurs nozzle y clearance increases allowing centralizing of the spool o to take place.
Series: 342 (VP300), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: B (24VAC), Electrical Entry: T (Conduit Terminal), Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread Type: N (NPT), Actuation Type: A (N.C., Normally Closed)
Series: 342 (VP300), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 4 [220VAC (230VAC), 50/60Hz], Electrical Entry: T (Conduit Terminal), Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread Type: N (NPT), Actuation Type: A (N.C., Normally Closed)
Model: 33, Orifice: 2 (2.2mm), Style: 0 (N.C., Single Unit), Option: C37, Seals: NBR, Class B, Suffix: Standard, Port Size: 02 (1/4), Thread: T (NPTF), Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Surge Suppressor: Z (w/Light and Surge Voltage Suppressor), Rectifier: None (for DC or AC Class H Coil), Bracket: B (Bracket)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)]
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)]
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)]
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A)
Series: 544 (VP500), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115VAC), 50/60Hz], Electrical Entry: T (Conduit Terminal), Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread Type: N (NPT), Actuation: A (N.C., Normally Closed)
Series: 544 (VP500), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115VAC), 50/60Hz], Electrical Entry: T (Conduit Terminal), Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread Type: N (NPT), Actuation: B (N.O., Normally Open)
Body Type: T (Body Ported), Valve Option: Standard, Voltage: 5 (24 VDC), Electrical Entry: D (DIN Terminal), Light & Surge Suppressor: Z (Light w/Surge Voltage Suppressor), Port Size: 02 (1/4, 8A), Thread: N (NPT)
Body Size: 20, Pipe Thread: N (NPT), Port Size: 02 (1/4), Mounting: w/o Mounting Option, Nominal Filtration Rating: 40 (40µ), Water Removal Type: T (Large Flow Type), Semi-standard: Z (Name Plate And Caution Plate For Bowl In Imperial Unit (PSI, °F))