This legacy series features a rugged all aluminum housing for durable installation. Oil vapor removal to 0.004 mg/m³; Modular connection is possible for AMF150C to 550C; Port size: 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1 1/2, 2; Threads: Rc, G, NPT
This legacy series features a rugged all aluminum housing for durable installation. Oil vapor removal to 0.004 mg/m³; Modular connection is possible for AMF150C to 550C; Port size: 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1 1/2, 2; Threads: Rc, G, NPT
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)], Operation Manual
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: Y
Nozzle Diameter: ø1.0mm, Vacuum Pressure: -48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A, SUP: Screw-in NPT 1/8, VAC: Screw-in NPT 1/8, EXH: Screw-in NPT 1/8, Accessories: w/o Bracket, w/o Silencer
Nozzle Diameter: ø1.0mm, Vacuum Pressure: -90 kPa, SUP: Screw-in NPT 1/8, VAC: Screw-in NPT 1/8, EXH: Screw-in NPT 1/8, Accessories: w/o Bracket, w/o Silencer
Nozzle Diameter: ø0.7mm, Vacuum Pressure: -48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A, SUP: Screw-in NPT 1/8, VAC: Screw-in NPT 1/8, EXH: Screw-in NPT 1/8, Accessories: w/o Bracket, w/o Silencer
Nozzle Diameter: ø0.7mm, Vacuum Pressure: -90 kPa, SUP: Screw-in NPT 1/8, VAC: Screw-in NPT 1/8, EXH: Screw-in NPT 1/8, Accessories: w/o Bracket, w/o Silencer
Nozzle Diameter: ø0.5mm, Vacuum Pressure: -48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A, SUP: Screw-in NPT 1/8, VAC: Screw-in NPT 1/8, EXH: Screw-in NPT 1/8, Accessories: w/o Bracket, w/o Silencer
A built-in exhaust silencer keeps generator noise to a minimum. Available in four nozzle diameters and a number of port sizes.
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: B [Panel Mount Adapter, (ZS-46-B)]
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)], Operation Manual: K (Operation Manual, Calibration Certificate)
Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B (ZS-46-A2)], Operation Manual: K (Operation Manual, Calibration Certificate)
Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B (ZS-46-A2)]
Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B (ZS-46-A2)], Operation Manual: K (Operation Manual, Calibration Certificate)
Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)
Pressure Range: F (-100.0 to 100kPa), Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: None, Calibration Certificate: K (w/Certificate
Pressure Range: 0.0 to -101.0kPa, Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: None, Calibration Certificate: K (w/Certificate)