Symbol (B) 2 (A) 4 1 (P) 3 (R) Flow Rate Characteristics C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv 14/2(PA/B) 4/25/3(A/BEA/EB) Flow rate characteristics Valve model Port size Body ported 10-VQD1121(V)-L M-M5 10-VQD1121 -L M-M5 10-VQD1151(V)-L M-M5 10-VQD1151W-L M-M5 0.05 0.07 0.06 0.07 Base mounted (With sub-plate) 0.22 0.27 0.22 0.27 0.16 0.24 0.10 0.25 0.05 0.07 0.05 0.07 0.19 0.28 0.22 0.27
Trace the arrow mark from the point A at an ambient temperature 86F (30C) to obtain the intersection B on the curved line for the relative humidity 60%. 2. Trace the arrow mark from the intersection B to obtain the intersection D on the pressure characteristic line for 102 psi (0.7 MPa). 3. Trace the arrow mark from the intersection D to obtain the intersection E. 4.
HS SMC SMC 16 29 A B Auto switch mounting positions Minimum strokes for auto switch mounting (mm) Basic type, Foot type, Flange type, Clevis type Mounting bracket Auto switch model B D-H7BA Applicable bore size (mm) 1 pc. (Rod cover side) 2 pcs. (Different sides) 2 pcs.
auto switch CP95KD B 32 100 W S Z76 With auto switch Number of auto switches Auto switch Nil S 3 n 2 pcs. 1 pc. 3 pcs. n pcs.
To adjust the cylinder speed, use a speed controller. 30 20 CXW32 10 CXWL25 CX2N25 Load mass (kg) CXW20 CX2N25-B, CXWM25 5 CXW16 4 CX2N15-B CX2N15 3 2 CX2N10-B CX2N10 CXW10 1 0.5 10 50 100 200 300 500 1000 Cylinder speed (mm/s) 462 Series CX2 Prior to Use 1. Changing from the non-auto switch specifications to the auto switch specifications 2.
C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv VP517Y G3/8 8.8 0.14 2 8.2 0.15 1.8 VP717Y G1/2 13.8 0.11 2.9 12.9 0.18 2.9 2 VP500/700 Series Spacer Center of F.R.L. body D C B Model A B C D Y300-A 4.2 43.4 21.7 57.9 Y400-A 5.2 53 26.5 68.5 A (Spacer width) Seal Y400-A Spacer with Bracket D K Center of F.R.L. body J H F G E E C B Seal A (Spacer width) Y400T-A Model A B C D E F G H J K Y300T-A 4.2
How to Calculate the Set Value A = Max. pressure value in auto preset mode B = Tentative min. pressure value in auto preset mode P1 = A (A B)/4 P2 = B + (A B)/4 Manual adjustment is possible after finishing in the auto preset mode. Ex.) When an error count (number of the failure predict) (EC) is set to be 3.
phase J A B C D A COM COM COM B 12 VDC GND F.G.
4 Body B O-ring Electroless nickel plated Brass NBR e !5 Body B O-ring Electroless nickel plated Brass NBR r !6 Needle Spacer Electroless nickel plated Brass POM (2) t !7 Seat ring Gasket Electroless nickel plated Brass NBR, Stainless steel y !8 Spring Retaining ring for hole type C Steel wire Tool steel u !
Piston rod deflection reduced Deflection of the piston rod has been reduced by increasing the precision of the bushing and piston rod, and reducing the tolerances. 6-13-2 6-13-3 3 ISO/VDMA Cylinder: Standard Type Double Acting with End of Stroke Cushioning Series CP95 32, 40, 50, 63, 80, 100 How to Order CP95S B 32 100 W Without auto switch CP95SD B 32 100 W S Z76 With auto switch Courtesy
Magnet Slide Bearing Felt Holder Ball bushing Piston seal Rod seal Gasket A Gasket B No. q w No. !
Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the and buttons simultaneously for 1 second or longer. -37No.PS-OMU0012-C [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.
8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433-1993: *2) 1. 2. 3. 1. 2. 3. 4
JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment for machines.
JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment for machines.
When pilot valve B is pushed, the air which was acting upon the switching valve is exhausted, and drive chamber B once again switches to a supply state. A continuous reciprocal motion is generated by this repetition. 1. When air enters drive chamber B, the fluid in pump chamber B is forced out, and at the same time Drive unit fluid is sucked into pump chamber A. 2.
A-phase pulse B-phase pulse 11 12 11 10 10 Count multiplier In rod extending direction, A-phase turns on first, then B-phase turns on with the delay of In rod retracting direction, B-phase turns on first, then A-phase turns on with the delay of approximately 90 phase difference. approximately 90 phase difference. Counter performs addition in and does subtraction in .
At this time, magnet B goes out of the movement range of auto switch B, causing auto switch B to turn OFF. Furthermore, the piston moves to the right, causing magnet A to enter the movement range of auto switch A. As a result, auto switch A turns ON.
Drive data value is wrong (048) B Input RESET
AMX-OM-Q014-B PRODUCT NAME Membrane Air Dryer MODEL / Series / Product Number IDG30A IDG50A IDG60LA,IDG60SA IDG75LA,IDG75SA IDG100LA,IDG100SA Contents 1. Safety Instructions 1 2. Installations and Operations 3 3. Maintenance and Checks 5 4. Specifications 6 1.