signal: Current type 0 to 20 mA DC, Monitor output: Switch output / NPN output, Bracket: L-bracket, Power Supply Voltage: 24 V DC
signal: 4-point preset input, Monitor output: No, Bracket: Flat-bracket, Power Supply Voltage: 24 V DC
signal: 4-point preset input, Monitor output: No, Bracket: Flat-bracket, Power Supply Voltage: 24 V DC
signal: 4-point preset input, Monitor output: No, Bracket: Without bracket, Power Supply Voltage: 24 V DC
signal: 4-point preset input, Monitor output: No, Bracket: Without bracket, Power Supply Voltage: 24 V DC
, Monitor output: No, Bracket: L-bracket, Power Supply Voltage: 24 V DC
: CC-Link, Monitor output: No, Bracket: Without bracket, Power Supply Voltage: 24 V DC
, Monitor output: No, Bracket: Without bracket, Power Supply Voltage: 24 V DC
RS-232C communication, Monitor output: No, Bracket: L-bracket, Power Supply Voltage: 24 V DC
RS-232C communication, Monitor output: No, Bracket: Without bracket, Power Supply Voltage: 24 V DC
: RS-232C communication, Monitor output: No, Bracket: Without bracket, Power Supply Voltage: 24 V DC
-232C communication, Monitor output: No, Bracket: Without bracket, Power Supply Voltage: 24 V DC
M9B D-M9B M9N D-M9N Solid state switch M9P D-M9P M9BW D-M9BW Solid state switch (2-color indication) M9NW D-M9NW M9PW D-M9PW *Note 1) lead wire length symbols 0.5mNil. (Case) M9NW 1mM (Case) M9NWM 3mL (Case) M9NWL 5mZ (Case) M9NWZ *Note 2) When 2 auto-switches are specified they are assembled for shipping.
M9B D-M9B M9N D-M9N Solid state switch M9P D-M9P M9BW D-M9BW Solid state switch (2-color indication) M9NW D-M9NW M9PW D-M9PW *Note 1) lead wire length symbols 0.5mNil. (Case) M9NW 1mM (Case) M9NWM 3mL (Case) M9NWL 5mZ (Case) M9NWZ *Note 2) This product can be mounted on the NEXTAGE KAWADA ROBOTICS CORPORATION. 3-2.
Wiring table for power supply cable IZS30-CP Pin Lead wire color Description Function 1 Brown DC21.6 to 26.4V Power supply DC + 24 V 2 Blue GND Power supply 0V. Be sure to apply class D grounding. 3 Green NC 4 Gray Stop signal of static charge elimination Connected 0V during operation.
Applicable cable of the power supply connector Cable cross section Single wire, stranded wire 0.2 mm2 to 2.5 mm2/AWG24 to 12 Power supply connector for solenoid valve Terminal Wire colour Connection 24 V For solenoid valve +24 V 0 V For solenoid valve 0 V Note Wiring should be carried out with the power supply turned off.
Tightening Torque for Auto Switch Mounting Screws(Nm) Auto switch model Tightening torque D-M9(V) D-M9W(V) D-M9A(V) D-P3DWA 0.05 to 0.15 The indicator light may turn on when the tip of the screwdriver is close to the auto switch mounting screw. This is not a malfunction.
V V V v v IC circuit 3-wire (PNP) M9PWV M9PW V V V v v 2-wire 12 V M9BWV M9BW V V V v v Relay, PLC Diagnostic indication (2-color indicator) 24 V Grommet Yes 3-wire (NPN) 5 V, 12 V M9NAV1 M9NA1 v v V v v IC circuit 3-wire (PNP) M9PAV1 M9PA1 v v V v v 2-wire 12 V M9BAV1 M9BA1 v v V v v Water resistant (2-color indicator) 1 Water resistant type auto switches can be mounted on the above models
V V V v v IC circuit 3-wire (PNP) M9PWV M9PW V V V v v Diagnostic indication (2-color indicator) Relay, PLC 24 V Grommet Yes 2-wire 12 V M9BWV M9BW V V V v v 3-wire (NPN) 5 V, 12 V M9NAV2 M9NA2 v v V v v IC circuit 3-wire (PNP) M9PAV2 M9PA2 v v V v v Water resistant (2-color indicator) 2-wire 12 V M9BAV2 M9BA2 v v V v v 1 Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example
V V v v IC circuit 3-wire (NPN) Solid state auto switch 5 V, 12 V 3-wire (PNP) M9PV V V V v v 2-wire 12 V M9BV V V V v v 3-wire (NPN) 5 V, 12 V M9NWV V V V v v IC circuit 3-wire (PNP) M9PWV V V V v v 2-wire 12 V M9BWV V V V v v Relay, PLC Diagnostic indication (2-color indicator) 24 V Grommet Yes 3-wire (NPN) 5 V, 12 V M9NAV v v V v v IC circuit 3-wire (PNP) M9PAV v v V v v 2-wire 12