SMC Corporation of America
Elite Part Number Search
Search Results "VV2Q22-16-00N"

Forward speed switch 16 forward speeds are available. SPEED Reverse speed switch 16 reverse speeds are available. !8 Forward acceleration switch 16 forward acceleration steps are available. ACCEL Reverse acceleration switch 16 reverse acceleration steps are available. CN1 Power supply connector Connect the power supply cable. !7 CN2 Motor connector Connect the motor connector.

(n = 4, 8, 12, 16) (n = 4, 8, 12, 16) (n = 4, 8, 12, 16) (n = 2, 4, 6, 8) With 2 pcs. (Different surfaces, Same surface), With 1 pc. 105 15 110 115 D-M9 D-M9W 115 + 40(n 4) 2 105 + 40(n 4) 2 110 + 40(n 4) 2 15 + 40(n 2) 2 With n pcs. (n = 4, 8, 12, 16) (n = 4, 8, 12, 16) (n = 4, 8, 12, 16) (n = 2, 4, 6, 8) With 2 pcs.

MGQM, MGQL Common Dimensions Bore size (mm) Standard stroke (mm) B Z G NN F MM ML DA L R C H K Q X GA GB J P PW S T TA TB V W YY YL 32 40 50 63 80 100 1/8 1/8 1/4 1/4 3/8 3/8 16 17 17 19 21 25 51 51 59 72 92 112 12.5 14 14 16.5 19 23 114 96 48 112 80 100 8 8 10 10 16 16 20 20 25 25 30 35 16 16 20 20 25 30 38 38 44 44 56 62 37.5 44 44 49 56.5 66 26 26 30 36.5 46.5 56.5 30 30 40 50 60 80 47.5

(DIN ) 1) 2) 3) 25 No.SFOD-OMT0009CN-B 4.2 (1) (9) (2) (10) (3) (4) (15) (16) (7) (11) (5) (12) (17) (8) (18) (19) (6) (20) (13) (14) 1 PWR LED() ON OFF 2 RUN LED I/O USB 3 USB USB LED USB USB 4 ALM LED 5 USB USB 6 C PWR 2 (+)(-) 7 I/O 1 I/O 40 I/O PLC 8 I/O 2 I/O 40 I/O PLC 9 ENC1 (16 ) 1 10 MOT1 (6 ) 11 ENC2 (16 ) 2 12 MOT2 (6 ) ) (+)1 (+) 1 (+)2 (+)2 (+) 13 CI 1 2 )

Axis 1, Axis 2 Motor drive power (+), common(-) 15 ENC3 Encoder connector (16 pins) Axis 3: Connect the actuator cable. 16 MOT3 Motor power connector (6 pins) 17 ENC4 Encoder connector (16 pins) Axis 4: Connect the actuator cable. 18 MOT4 Motor power connector (6 pins) 19 CI 3 4 Motor control power supply Motor control power supply(+), Axis 3 stop(+), Axis 3 unlock(+), Axis 4 stop(+), Axis

Series PCW e-con specification Conventional Series PCW PLC input/output PLC input/output Branch unit Branch 16 point unit 16 point unit 16 point unit 16 point unit Reverse connection detection function Visual indication of incorrect wiring of power supply terminal block and power supply status is provided.

Unit Unit part number Unit ID Configuration data size [byte] SI unit EX600-SEN3-X80 (32 outputs) 9Bh 27 EX600-DX#B (8 inputs) 01h 4 EX600-DX#C (8 inputs) 03h 4 EX600-DX#D (16 inputs) 05h 5 Digital input unit EX600-DX#E (16 inputs) 14h 5 EX600-DX#F (16 inputs) 16h 5 EX600-DX#C1 (8 inputs) 0Dh 5 EX600-DY#B (8 outputs) 08h 9 Digital output unit EX600-DY#E (16 outputs) 18h 15 EX600-DY#F (16 outputs

Item Decimal Comm Format "Data-SINT" Input 16 [bytes] Output 16 [bytes] Configuration 0 [bytes] (4)(5) (1) 16 (2) 16 (3) -41No. JXC-OMU0026 6.

/O.D. mm Series Body size 6.5/10 8.5/12.5 5/8 6/9 8/12 11/16 KK3 KK4 KK6 1/8 1/4 1/2 One-touch fitting type Applicable tubing O.D. mm Series Body size 16 8 10 12 4 6 KK3 KK4 KK6 1/8 1/4 1/2 Manufactured by Rectus Series KK13 Series KK13 Applicable hose I.D.

-12-12-12 ZH20DS-12-16-16 ZH20DL-12-16-16 12 12 16 16 15.8 35.5 50 17 10 15.8 35.5 50 10 17.2 38.5 54.3 12 17.2 38.5 54.3 12 12 12 16 16 17 21.7 21.7 One-touch and screw-in connection Applicable tubing diameter N Applicable tubing diameter E S type: White color L type: Black color (Mounting hole) B C D E F G H Model A ZH18DS-12-03-12 ZH18DL-12-03-12 ZH20DS-12-04-16 ZH20DL-12-04-16 12 12 12

stations 16 stations 8 16 Note 1) Separately order the 20P type cable assembly for the P kit.

Metric size 3.2 4 6 8 10 3.2 4 6 8 10 6 8 10 12 10 12 16 Tubing O.D.

20 1 MXS 20 16 16 0.1 0.01 MXQ 10 10 6 6 MXF 0.01 0.001 0.1 0 20 40 60 80 100 0 20 40 60 80 100 0 20 40 60 80 100 MXW Overhang L (mm) Overhang L (mm) Overhang L (mm) MXJ Graph (5) Load Eccentricity 100 mm Graph (8) Load Eccentricity 100 mm Graph (11) Load Eccentricity 100 mm MXP 1 10 10 MXY Mass m (kg) 0.1 MTS 1 Mass m (kg) Mass m (kg) 20 16 10 6 1 20 20 16 10 16 0.01 0.1 10 6 6 0.001 0.1

Item Reference page 16-2-30 Output type Example of internal circuit and wiring 16-2-31 Auto shift function, Anti-chattering function 16-2-32 Measures to be taken when error occurs 16-2-33 16-2-38 15 Series ZSE60F/ISE60 High Precision, Digital Pressure Switch for General Fluids Dimensions Bracket A A 30 20 ZSE ISE 20 PSE 45 Z I SE3 55 4.5 11.5 40 15 PS 4.5 Z I SE1 2 Courtesy of Steven Engineering

Figures in body of chart are suggested minimum rod diameters Exposed Length of Piston Rod (IN) Tons 10 20 40 60 70 80 100 120 1/2 3/4 1 3/4 13/16 1-1/16 1 5/8 7/8 1-1/8 1-1/4 1-3/8 1-1/2 11/16 15/16 1-3/16 1-3/8 1-1/2 2 3/4 1 1-1/4 1-7/16 1-9/16 1-3/16 3 13/16 7/8 1-1/8 1-3/8 1-9/16 1-5/8 1-7/8 4 15/16 1 1-3/16 1-1/2 1-5/8 1-3/4 2 2-1/4 5 1 1-1/8 1-5/16 1-9/16 1-3/4 1-7/8 2-1/8 2-3/8 7-1/

Figures in body of chart are suggested minimum rod diameters Exposed Length of Piston Rod (IN) Tons 10 20 40 60 70 80 100 120 1/2 3/4 1 3/4 13/16 1-1/16 1 5/8 7/8 1-1/8 1-1/4 1-3/8 1-1/2 11/16 15/16 1-3/16 1-3/8 1-1/2 2 3/4 1 1-1/4 1-7/16 1-9/16 1-3/16 3 13/16 7/8 1-1/8 1-3/8 1-9/16 1-5/8 1-7/8 4 15/16 1 1-3/16 1-1/2 1-5/8 1-3/4 2 2-1/4 5 1 1-1/8 1-5/16 1-9/16 1-3/4 1-7/8 2-1/8 2-3/8 7-1/

Auto Switch Proper Mounting Position for Stroke End Detection MY1CW 16, 20 MY1MW 16, 20 B A Reed switch D-A90(V), D-A93(V), D-A96(V) Solid state switch D-F9N(V), D-F9P(V), D-F9B(V) D-F9NW(V), D-F9PW(V), D-F9BW(V) Mounting position 20 16 20 16 20 Mounting position Mounting position 16 A 90 70 93 73 94 A A 74 B 110 90 107 87 106 B B 86 Operating range Note) 7.5 11 6.5 8.5 6.5 Operating range

HS Auto switch 8.5 12 24.5 16 A B A B 26 33 D-H7, D-H7W D-H7F, D-H7BA D-C73C, D-C80C Approx. HS Approx. HS Auto switch Auto switch 8.5 8.5 16 16 A B A B 29 (36) 36.7 Numbers inside ( ) are for type D-H7LF. D-H7C D-B5, D-B6, D-B59W Approx. HS Approx.

Flow Rate and Effective Area AS12 1F-M3 AS13 1F-M3 AS12 1F-M5 AS13 1F-M5 AS22 1F-01 AS23 1F-01 AS22 1F-02 AS23 1F-02 AS32 1F AS33 1F AS42 1F AS43 1F Model Metric size 3.2, 4 3.2, 4, 6 3.2, 4 6, 8, 10 8,10 4 6 6 8 10 12 10, 12 Tubing O.D. 1/8" 5/32" 1/8", 3/16" 1/8" 5/32" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" Inch size 5/32" 3/16" 5/16" 3/8" 1/2" 3/8" 1/4" 1/4", 5/32" Controlled flow (Free flow

16 29 Hs Hs 26 B A B A D-B5/B6/B59W D-G5NTL 12 24.5 24.5 Hs B A 33 Hs 33 A B D-H7C D-C73C/C80C CV MVGQ 16 16 Hs Hs B A 36.7 B A 36.7 Auto Switch Proper Mounting Position (Detection at Stroke End) and Mounting Height Auto Switch Proper Mounting Position (mm) D-C7 D-C80 D-C73C D-C80C A D-H7 D-H7C D-H7W D-H7NF Auto switch model D-A9 D-M9 D-M9W D-B59W D-B5 D-B64 D-G5NTL Bore size (mm)