[P_2] Set value of OUT2 500 L/min 1000 L/min Brown DC(+) Brown DC(+) 1 1 IO-Link status indicator light LED is ON when OUT1 is used in IO-Link mode.

For product installation at a place of high altitude of 1000 meters or more, select a thermo-chiller of the applicable capacity referring to the table below. 1. Max. ambient temp.: Use the product in lower ambient temperature than the described value at each altitude. 2.

The value used for consideration should not be the very limit for the safety. 6.2.1 Performance of HEC006 1) Cooling capacity Radiating Water Temp.20 oC Radiating Water flowrate8L/min 1500 Cooling capacity W 1000 Fluid: Water 500 Fluid: Fluorinert FC-77 0 0 10 20 30 40 50 60 70 Recirculating fluid temp. oC Fig. 6-1 Cooling capacity of HEC006 2) Heating capacity Radiating Water Temp.20 oC

.: 25oC 1) Cooling capacity 800 Facility water 10oC Facility water 25oC 600 Cooling capacity W Facility water 35oC 400 200 0 0 10 20 30 40 50 60 70 Recirculating fluid temp. oC Fig. 9-7 Cooling capacity (HED003) 2) Heating capacity 1000 800 Heating capacity W Facility water 35oC 600 400 Facility water 10oC 200 Facility water 25oC 0 0 10 20 30 40 50 60 70 Recirculating fluid temp. oC Fig.9

For product installation at a place of high altitude of 1000 meters or more, select a thermo-chiller of the applicable capacity referring to the table below. 1. Max. ambient temp.: Use the product in lower ambient temperature than the described value at each altitude. 2.

Graph 1Allow lateral load 1000 Lateral load to rod end (N) 100 160 125&140 10 0 500 1000 1500 2000 Stroke(mm) Judging lateral load of dead weight In case of rotating type cylinder, lateral road applies to the piston rod because of dead weight of the cylinder. It needs to be checked, if the lateral load is within the range of safety.

Electrical entry Grommet Lead wire Vinyl sheath cable 4.8, 0.5 mm2, 2-wire Impact proof 1000 m / s2 Insulation resistance 50 M or more under the test voltage 500 VDC (between case and cable) Withstand voltage 1000 VAC 1min (between case and cable) Ambient temperature -10 to 60 C Enclosure IEC60529 criteria IP67 Standards CE, UL, RoHS Magnetic field resistance When the alternative welding

Contact SMC when there is a problem of switchs ON/OFF positions (hysteresis). -7No.D-S-OMZ0004 Model Indication and How to Order D-M7BA Lead wire length and termination 2-wire Symbol Specification L 3000 mm (Half strip) Z 5000 mm (Half strip) SAPC 500 mm (M8 3-pin pre-wire) SBPC 500 mm (M8 4-pin pre-wire) SDPC 500 mm (M12 4-pin pre-wire) MAPC 1000 mm (M8 3-pin pre-wire) MBPC 1000 mm (M8 4

LECGPR1 1 2 3.4 3LEC LEC 4. 4 LEC 4 LEC 4 5 CN1~CN3 5. 8 - 6 DC24V LEC LEC LEC 12.4 LED LED PWR CN2 STAT CN2TB/PC BUS STAT IF ALM SF BF LED 10.LED ALM LED 7 12.LEC 9 - 3 31 DC24V10% 200mA 300mA LEC 5 57words 57word UL , UL1310 Class2 Profibus Profibus DP V1 DP slave 0125 ID 1414 GSD Dsub 9.6k 19.2k 45.45k 93.75k 187.5k 500k 1500k 12000k (bps) (m) 1200 1000

600 750 1000 Purge air flow rate L/min(ANR) 125 150 190 65 80 110 Inlet air pressure MPa Inlet air temperature oC Inlet air saturation temperature oC Ambient temperature oC *Note 1 *Note 1 -15 -20 *Note 2 Standard performance conditions *Note 3 0.7 25 25 25 Dew point indicator purge air flow rate 1L/min (ANR) {In case of inlet air pressure 0.7 MPa} 1/2 1/2 Port size 3/8 1/2 3/8 1/2 1.50

Parameter Initial value Initial value Selection range (value) 2 (mm) Value/Range Setpoint 1 (SP1) 250 12.5 mm D-MP025 0 to 500 Setpoint 2 (SP2) 230 11.5 mm Measuring range 0 to 500 25 mm Setpoint 1 (SP1) 500 25 mm D-MP050 0 to 1000 Setpoint 2 (SP2) 480 24 mm Measuring range 0 to 1000 50 mm Setpoint 1 (SP1) 1000 50 mm D-MP100 0 to 2000 Setpoint 2 (SP2) 980 49 mm Measuring range 0 to 2000 100

degC Fig. 6-1 Cooling capacity 2) Heating capacity Fluid: water Fluid: water 1000 2000 900 Ambient 35C 1800 Ambient 30C 800 1600 Ambient 25C Heating capacity W Heating capacity W 700 1400 600 Ambient 20C 1200 500 Ambient 15C 1000 400 800 300 Ambient 15C 600 200 400 100 0 200 10 15 20 25 30 35 40 45 50 10 15 20 25 30 35 40 45 50 Circulating fluid temperature degC Fluid temperature degC Fig

SY 3000, 5000, 7000, 9000 SYJ 3000, 5000, 7000 S0700 0700 VQZ 1000, 2000, 3000 Plug-in type Valve series Model No.

Radiating water Temp.20 Ambient Temp.20 Fluid water 1000 Cooling capacity W 5 Radiating water flow rate L/min 800 1 3 600 400 200 0 0 10 20 30 40 50 60 70 Recirculating fluid temp. Fig. 5-7 Cooling capacity 5-6 Operation 2) Heating capacity Recirculating fluid flowrate5L/min Ambient Temp.20 Fluid water 1000 Heating capacity W Radiating water Temp.

Indication resolution How fine the rated pressure range can be displayed (example: If a product for 0 to 1 MPa can display pressure by 0.001 MPa, the display resolution is 1/1000.) Indicator LED The LED that turns on when the switch output is on. Indication unit The unit of pressure used on the display.

How fine the rated pressure range can be displayed (example: If a product for 0 to 1 MPa can display pressure by 0.001 MPa, the display resolution is 1/1000.) Indication resolution Indicator LED The LED that turns on when the switch output is on. Indication unit The unit of pressure used on the display.

The part number for bracket assembly for 1000 cm3 is AF50P-050AS (applicable to the AL30 to AL60).

V = 2gH/1000 x 60 Obtain the total amount of the workpiece. Total weight m = 10 x 0.1 (kg) = 1 (kg) Obtain the intersection of the transfer speed V and the total weight of workpiece m.

AS2301F-02, AS2311F-02 AS2201F-02, AS2211F-02 AS3201F, AS3211F AS4301F, AS4311F AS4201F, AS4211F AS3301F, AS3311F Supply pressure: 0.5MPa Supply pressure: 0.5MPa Supply pressure: 0.5MPa 16 25 6 400 1000 14 10, 12 1500 12 80, 10 20 12 Effective area (mm2) Effective area (mm2) 08 06 Effective area (mm2) 300 10 Flow (l/min(ANR)) Flow (l/min(ANR)) Flow (l/min(ANR)) 06 10 1000 4 15 500 8 04 200

1000 MQML: Standard type MQMLH: High speed/High frequency type Maximum speed V(mm/s) Note 1) When a load is attached to the rod end, adjust the speed so that the maximum speed is no more than that shown in the graph for the corresponding load weight.