Rated Pressure Range: -0.1 to 2 MPa, Piping: Rc1/8, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: w/Unit Display Switching Function, Option 2: None, Option 3: Calibration Certificate, X Options: -

Rated Pressure Range: -0.1 to 2 MPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: w/Unit Display Switching Function, Option 2: None, Option 3: Calibration Certificate, X Options: -

Rated Pressure Range: -0.1 to 2 MPa, Piping: R1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: w/Unit Display Switching Function, Option 2: None, Option 3: Calibration Certificate, X Options: -

Rated Pressure Range: -0.1 to 2 MPa, Piping: R1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: w/Unit Display Switching Function, Option 2: None, Option 3: Calibration Certificate, X Options: -

Rated Pressure Range: -0.1 to 2 MPa, Piping: URJ1/4, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: w/Unit Display Switching Function, Option 2: None, Option 3: Calibration Certificate, X Options: -

Rated Pressure Range: -0.1 to 1 MPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: w/Unit Display Switching Function, Option 2: None, Option 3: Calibration Certificate, X Options: -

Rated Pressure Range: -0.1 to 2 MPa, Piping: NPT1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: w/Unit Display Switching Function, Option 2: None, Option 3: Calibration Certificate, X Options: -

Rated Pressure Range: -0.1 to 1 MPa, Piping: G1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: w/Unit Display Switching Function, Option 2: None, Option 3: Calibration Certificate, X Options: -

Rated Pressure Range: -0.1 to 2 MPa, Piping: Rc1/8, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: w/Unit Display Switching Function, Option 2: None, Option 3: Calibration Certificate, X Options: -

Rated Pressure Range: -0.1 to 1 MPa, Piping: URJ1/4, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: w/Unit Display Switching Function, Option 2: None, Option 3: Calibration Certificate, X Options: -

Rated Pressure Range: -0.1 to 1 MPa, Piping: Rc1/8, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: w/Unit Display Switching Function, Option 2: None, Option 3: Calibration Certificate, X Options: -

Rated Pressure Range: -0.1 to 2 MPa, Piping: TSJ1/4, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: w/Unit Display Switching Function, Option 2: None, Option 3: Calibration Certificate, X Options: -

Rated Pressure Range: -0.1 to 2 MPa, Piping: TSJ1/4, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: w/Unit Display Switching Function, Option 2: None, Option 3: Calibration Certificate, X Options: -

Rated Pressure Range: -0.1 to 1 MPa, Piping: TSJ1/4, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: w/Unit Display Switching Function, Option 2: None, Option 3: Calibration Certificate, X Options: -

Rated Pressure Range: -0.1 to 2 MPa, Piping: G1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: w/Unit Display Switching Function, Option 2: None, Option 3: Calibration Certificate, X Options: -

Rated Pressure Range: -0.1 to 1 MPa, Piping: R1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: w/Unit Display Switching Function, Option 2: None, Option 3: Calibration Certificate, X Options: -

Rated Pressure Range: 1 to -101 kPa, Piping: NPT1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: W/Unit Display Switching Function, Option 2: None, Option 3: Calibration Certificate, X Options: -

Rated Pressure Range: 1 to -101 kPa, Piping: R1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: W/Unit Display Switching Function, Option 2: None, Option 3: Calibration Certificate, X Options: -

Af t er set t i ng t he sw i t ch, t i ght en t he sw i t ch cover i n t he reverse order of t he above procedure. ( Ti ght eni ng t orque 0. 6 t o 0. 8N m ) Setting of node address and com m unication rate Pl ease execut e t he set t i ng of node address and t ransm i ssi on rat e w i t h t he di p sw i t ch. 1 2 3 4 5 6 7 8 9 10 SW 40 SW 20 SW 10 SW 08 SW 04 SW 02 SW 01 BS4 BS2 BS1 Tabl