SMC Corporation of America
Elite Part Number Search
Search Results "CVQB40-40-5M"

If controlling using a PLC or other upper device, please turn off the power and reset the device before use.) -40- 5.4.1 JOG Mode In order to prevent accidental impact at the end of the stroke, test actuator operation at low speed. See LECSC2-T Operation Manual (Simplified Edition),section 5.6.2 for motor speed configuration.

Operating ambient humidity 35 to 85%RH (No dew formed) Storage humidity 35 to 85%RH (No dew formed) 24VDC+/-10% Max. 8mA/point Display LED POWER, A-PHASE, OFF, SET 24VDC 10% Supply source Storage temp. 0 to +40 oC (Non freezing) Input signal Photo-coupler input Applicable motor A3 DC motor Type3 A5 DC motor Type5 B Nothing included Operating ambient temp. +5 to +40 oC included Weight 145g

Product part number Auto drain number Normally closed Normally open HAW2-04C/D AD402-04C-6-A AD402-04D-6-A HAW7-06D AD402-04D-6-A HAW22/37-14D AD600-06 HAW55/75-20D AD600-06 HAW110-30D AD600-10 2) The drain piping, if conducted, should have an inside diameter of at least 10mm and a maximum length of 5m.

The drain piping should have an internal diameter of 8mm or more and be 5m or less in length. Make sure that it does not go upwards and it is not bent. The outlet end of the tube is released to atmosphere, and lets the drain flow through the tube. Ensure that the ball valve is opened. Refer to 7.3 Dimensions of the Chapter 7.

Coefficient factors Inlet air temperature (oC) 35 40 45 50 55 60 65 70 75 80 1.58 1.46 1.09 1.00 0.79 0.64 0.55 0.51 0.49 0.47 Inlet air pressure (MPa) 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 to 1.6 0.67 0.79 0.88 0.91 1.00 1.02 1.04 1.09 Ambient temperature (oC) 20 25 30 35 40 45 1.19 1.13 1.06 1.00 0.90 0.77 Calculation example: The air flow capacity when the dew point of IDFC60 is set to 10 oC

Coefficient factors Inlet air temperature (oC) 5 to 25 30 35 40 45 50 55 60 65 1.42 1.15 1.00 0.71 0.62 0.50 0.40 0.33 0.21 Inlet air pressure (MPa) 0.3 0.4 0.5 0.6 0.7 to 1.6 0.71 0.75 0.82 0.89 1.00 Ambient temperature (oC) 2 to 25 30 35 40 45 1.0 0.85 0.80 0.73 0.62 Calculation example: The air flow capacity when the dew point of IDFA60 is set to 10 oC under the following conditions <

No.PS-OMU0005CN-C // ZSE20B(F) ISE20B 2 8 10 11 15 15 17 20 [] 23 24 3 25 27 29 29 29 F0 31 F1 OUT1 32 F1 OUT2 35 F3 37 F4 38 F5 FUNC 40 F6 42 F10 43 F11 49 F80 50 F81 51 F82 53 F90 54 F96 56 F97 57 F98 59 F99 61 62 66 66 67 76 76 79 -1No.PS-OMU0005CN-C (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO

WH1) 1 1Er689o.rEr12() : OUT1OUT212 ()P_1P_2 -35No.PS-OMU0008CN-D [F 2] OUT2 OUT2 ONON 35 <> [F 2] [OFF] 26 [Err] [P_2] [P2L][P2H] [P_2] [n_2] Pn (63 ) -36No.PS-OMU0008CN-D 26 [H_2] [WH2] (63 ) 28 ON ON ON ON OFF OFF OFF OFF OUT1 OUT1 OUT2 OUT2 [F 2] OUT2 1 2 2 -37No.PS-OMU0008CN-D [F 3] <> [F 3] [F 3] 190 2(283437) -38No.PS-OMU0008CN-D [F 4] <> [F 4] [F 4] (40

VFR5000-OMN0001 / / / / 1 1 3) 3) 1 1 () 3 VFR5000-OMN0001 VFR5000 Series 5 / 1 DC 3 () 0.1 2 C-R () C-R DC 3% AC 20% ( ) () () 3 3 EXH (VVFS5000-R-04-1,2) ( ) () 3 4 No.VFR5000-OMN0001 VFR5000 Series 5 / (SSR )AC 1) (C-R ) OFF 2)() 1 -10 1 1) M5 1/6~1/4 1~1.5Nm ) ( ) 2 Rc Nm Rc 1/8 7~9 Rc 3/8 22~24 Rc 1/2 28~30 Rc 3/4 28~30 5 No.VFR5000-OMN0001 VFR5000 Series 5 / ( ) 5m

Size: 40, Motor Mounting Position: D (In-line), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 100mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: F (Rod Flange, Top Mounting & In-line), Actuator Cable Type, Length: R5 (5m), Controller: CL1 (IO-Link), Mounting: 7 (Screw Mounting)

Size: 40, Motor Mounting Position: D (In-line), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 100mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: F (Rod Flange, Top Mounting & In-line), Actuator Cable Type, Length: R5 (5m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 7 (Screw Mounting)

Size: 40, Motor Mounting Position: Top Mounting, Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 200mm, Motor Option: W (w/Lock/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: L (Foot, Top Mounting), Actuator Cable Type, Length: R5 (5m), Controller: CL1 (IO-Link), Mounting: 7 (Screw Mounting)

The filtration degree should be 5m or finer. 2. Install an air dryer, after cooler, etc. Air that includes much condensate causes malfunction of valves and other pneumatic equipment. To prevent this, install an air dryer or after cooler, etc. 3. Use the product within the specified range of fluid and ambient temperature.

Miniature Fittings M3, R(PT) 1/8, M5 Series M Series M5 Manifold: M-5M Bulkhead reducer: M-5ER Panel mounting plate thickness max. 3.5mm For the plate thickness 3.5 to 6mm, give the plate tapping M12 0.75, and then screw-in. For the plate thickness 3.5 to 6mm, give the plate tapping M12 0.75, and then screw-in.

Electric Actuator with Integrated Guide Incorporating Recirculating Ball Frame-Type Linear Guide Incorporating Recirculating Ball Frame-Type Linear Guide Series LTF Light-weight, compact electric Light-weight, compact electric Frame-type linear guide has one-piece Frame-type linear guide has one-piece Space saving, light weight Space saving, light weight 50 40 46 33 60 74 LTF8 work piece

Series: LEFS (Ball Screw Drive), Accuracy: Basic Type, Size: 40, Motor Mounting Position: In-line, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm), Stroke: 500mm, Motor Option: w/o Lock, Auto Switch Mounting Bracket: None, Grease Application: with, Positioning Pin Hole: Housing B, Bottom, Actuator Cable: R (Robotic Flexible Cable

Series: LEFS (Ball Screw Drive), Accuracy: Basic Type, Size: 40, Motor Mounting Position: R (Right Side Parallel), Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm), Stroke: 200mm, Motor Option: B (w/Lock), Auto Switch Mounting Bracket: None, Grease Application: with, Positioning Pin Hole: Housing B, Bottom, Actuator Cable: R (Robotic

Cable Length: 5 (5m), Controller Type - LEC, JXC: 6P (LECA6 PNP, Servo Motor, Step Data Input Type), I/O Cable Length for LEC: 3 (3m)