SMC Corporation of America
Elite Part Number Search
Search Results "CDQSB25-75DC-M9BL3"

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating) / Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating) / Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating) / Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating) / Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating) / Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves

Magnet: Built-in Magnet, Mounting: Through Hole, Both Ends Tapped, Bore Size: 25mm, Stroke: 100mm, Option: Rubber Bumper, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in Magnet, Mounting: Through Hole, Both Ends Tapped, Bore Size: 25mm, Stroke: 100mm, Option: Rubber Bumper, Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: -

Magnet: Built-in Magnet, Mounting: Through Hole, Both Ends Tapped, Bore Size: 25mm, Stroke: 10mm, Option: Rubber Bumper, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in Magnet, Mounting: Through Hole, Both Ends Tapped, Bore Size: 25mm, Stroke: 175mm, Option: Rubber Bumper, Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: -

Magnet: Built-in Magnet, Mounting: Through Hole, Both Ends Tapped, Bore Size: 25mm, Stroke: 20mm, Option: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in Magnet, Mounting: Through Hole, Both Ends Tapped, Bore Size: 25mm, Stroke: 20mm, Option: Rubber Bumper, Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: -

Magnet: Built-in Magnet, Mounting: Through Hole, Both Ends Tapped, Bore Size: 25mm, Stroke: 25mm, Option: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in Magnet, Mounting: Through Hole, Both Ends Tapped, Bore Size: 25mm, Stroke: 25mm, Option: Rod End Male Thread, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in Magnet, Mounting: Through Hole, Both Ends Tapped, Bore Size: 25mm, Stroke: 75mm, Option: Rubber Bumper, Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: -

Magnet: Built-in Magnet, Mounting: Through Hole, Both Ends Tapped, Bore Size: 25mm, Stroke: 300mm, Option: Rubber Bumper, Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: -

Magnet: Built-in Magnet, Mounting: Through Hole, Both Ends Tapped, Bore Size: 25mm, Stroke: 50mm, Option: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in Magnet, Mounting: Through Hole, Both Ends Tapped, Bore Size: 25mm, Stroke: 200mm, Option: Rubber Bumper, Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: -

Magnet: Built-in Magnet, Mounting: Through Hole, Both Ends Tapped, Bore Size: 25mm, Stroke: 250mm, Option: Rubber Bumper, Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: -