to 60C (with no condensation or freezing) Ambient temperature range Operating/Stored: 35 to 85% RH (with no condensation) Ambient humidity range Withstand voltage Environmental resistance 1000VAC for 1min. between lead wires and body 50MW or more (at 500VDC) between lead wires and body Insulation resistance 10 to 500Hz at the smaller of amplitude 1.5mm or acceleration 98m/sX (10G) in X,
When making drain exhaust piping, use piping with bore size 10 or larger than 10. Length should be shorter than 5 m. Do NOT make upward piping. 2. Float type auto-drain (N.C.) DO NOT pipe upwards. (ANR)}. 2) Set pressure more than 0.1 MPa. 2. Float type auto-drain (N.C.) 1) Compressor can be used even if energy is under 3.7 kw. 2) Set pressure more than 0.15 MP 14-3-14
SDN1: 32 points SDN2: 16 points Number of outputs 32 points Connection load Series SJ2000/3000 manifold valves Output when communication error occurs Hold/Clear (Switch setting) Enclosure IP20 10 to 50C Operating temperature range Operating humidity range 35 to 85%RH (With no condensation) Withstand voltage 500 VAC for 1 min. between external terminals and FG EX 10 M or more (500 VDC) between
Shock Absorber Specifications RB1007 RB1412 RB2015 RB2725 Shock absorber model MGG20 MGG25, 32 MGG80, 100 Applicable guide cylinder MGG40,50,63 Maximum energy absorption (J) 5.88 19.6 58.8 147 Stroke absorption (mm) 7 12 15 25 DMaximum collision speed (m/s) 5 70 45 25 10 Max. operating frequency (cycle/min) -X Ambient temperature range ( C) 10 to 80 Individual -X 4.22 6.86 8.34 8.83 Spring
PS Note C2L Connector for pressure sensor controller ZS-28-C 1 pc. per set ISA Sensor cable ZS-26-F Cable length: 3 m Cable length: 3 m Note) At the factory, the connector is not attached to the cable, but packed together with it for shipment. The connector is not attached to the cable at the time of shipment.
Performance Weight g Recommended flow m3/min(ANR) Effective area mm2 Sonic conductance C [dm3/(sbar)] Model AN05-M5 AN10-01 AN15-02 AN20-02 AN30-03 AN40-04 0.4 or less 0.5 5 1 1 10 2 0.8 or less 3 2.5 15 1.0 or less 4 7 35 3.0 or less 60 12 5.0 or less 5.5 90 8.0 or less 18 8.5 Note) Recommended flow rate is the flow at 72.5psi (0.5 MPa) in the inlet pressure.
Bore size (Standard stroke (mm)) Bore size 4.5 6 8 Symbol 4 6 8 Stroke 5, 10 5, 10, 15 5, 10, 15, 20 Auto switch Nil Without auto switch (Built-in magnet) Adjuster option For the applicable auto switch models, refer to the table below.
MLU Standard Stroke MLGP Bore size (mm) 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Standard stroke (mm) ML1C 20, 25 32, 40, 50, 63, 80, 100 Manufacture of Intermediate Stroke Description Part no. Spacer is installed in the standard stroke body. Refer to How to Order for the standard model no. on page 816.