SMC Corporation of America
Elite Part Number Search
Search Results "S070C-5CG-32-X26-10"

(P, R port) 2 x 4.5 (Mounting hole) 39 23 8 (Pitch) 1.5 10.5 49.5 (Station 1) (Station n) 4 x M3 x 0.5 depth 6 (Bracket mounting screw) (Pitch) n x Rc 1/8 (A port) L Dimension n L n: Stations 1 37 27 20 398 388 13 32 51 70 89 108 127 146 165 184 203 222 241 260 279 298 317 336 355 374 2 56 46 3 75 65 4 94 84 5 113 103 6 132 122 7 151 141 8 170 160 9 189 179 10 208 198 11 227 217 12 246 236

Note 3) For wear ring A of 10, please consult with SMC. Seal kit includes a grease pack (6, 10: 5 and 10 g, 15 to 40: 10 g). Order with the following part number when only the grease pack is needed. Grease pack part no. for 6, 10: GR-F-005 (5 g) for external sliding parts, GR-S-010 (10 g) for tube interior Grease pack part no. for 15 to 40: GR-S-010 (10 g) 114

9 6, 10: Not available Wear ring A Special resin CY3B6-PS 6 CY3B6-PS Wear ring B Special resin Set of left nos. !6, !7, !8, !9 CY3B10-PS 10 CY3B10-PS Piston seal NBR Lubretainer 6: Not available Special resin CY3B15-PS 15 20 25 32 40 50 63 CY3B15-PS CY3B20-PS CY3B25-PS CY3B32-PS CY3B40-PS CY3B50-PS CY3B63-PS CY3B20-PS Cylinder tube gasket 6, 10 only NBR CY3B25-PS Set of left nos. !5, !

No.PF-OMO0007CN / / PF2A7## 2 10 12 13 15 15 16 17 19 20 21 22 25 F_1 26 F_2 () 27 F_3 28 30 31 32 32 34 35 35 37 38 40 -1No.PF-OMO0007CN (ISO/IEC)(JIS) 1) 2) 1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (

Design the machinery to avoid such dangers. 10 2-9-1. Mounting bracket Mounting nut should be tightened while keeping all the tension equal. When they are tightened , please use proper tightening torque. {(Refer to Table 10 (P29)) Before mounting a support bracket, make sure the product is aligned by placing on the leveled surface.

ISA PV 6.5 PSE 8 V 10 IS 10 17.6 5.5 2 x 3.3 Mounting hole Vacuum supply port M5 x 0.8 Vacuum pad connection port M5 x 0.8 ISG ZSM Connector type: ZSE2-0X-15C Indicator light (Red) 20 L H SET Vacuum supply port Vacuum pad connection port 7 35.6 Pressure setting trimmer Pneumatic circuit 600 (3000) + O 32 59 58 10.2 PV 6.5 18 V 8 10 17.6 10 5.5 2 x 3.3 Mounting hole Vacuum supply port M5 x

Hexagon width across flats (mm) Adjustable spanner nominal (mm) Male thread Suitable screw torque (Nm) M3 4.5 1/4 M5 10/32-UNF 1/6 turn after hand tightening 6. Do not apply excessive force or shock to the body or fittings with an impact tool.

Note 2) For wear ring A of 10, please consult with SMC. Seal kit includes a grease pack (6, 10: 5 and 10 g, 15 to 40: 10 g). Order with the following part number when only the grease pack is needed. Grease pack part no. for 6, 10: GR-F-005 (5 g) for external sliding parts, GR-S-010 (10 g) for tube interior Grease pack part no. for 15 to 40: GR-S-010 (10 g) 113

Note 2) For wear ring A of 10, please consult with SMC. Seal kit includes a grease pack (6, 10: 5 and 10 g, 15 to 40: 10 g). Order with the following part number when only the grease pack is needed. Grease pack part no. for 6, 10: GR-F-005 (5 g) for external sliding parts, GR-S-010 (10 g) for tube interior Grease pack part no. for 15 to 40: GR-S-010 (10 g) 113

Part Number Description: BKT MTG SW NCDG*32   Product Line: A   Product Line Description: ACTUATOR   Family Code: 573   Family Description: AUTO-SWITCH BRACKET   Class Code: 22   Part Code: 2   Reference Code:  K   This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number

Specifications Fluid Air Proof pressure 1.5MPa Max. operating pressure 1.0MPa Min. operating pressure 0.05MPa -10 to +60oC. -10 to +60o Ambient and fluid temperature C with built-in magnet (No freezing) Lubrication Not required (non-lube) Stroke length tolerance to 250st +1.0 mm 0 +1.4 mm 251 to 1000st 0 Cushion Air cushion or Rubber bumper Piston speed 50 to 500mm/sec Action Double acting

Do not use a cable longer than 10 m. Consult with SMC for the use with a cable longer than 10 m.

If using the product to detect very small pressures, warm up the product for 10 to 15 minutes first. There will be a drift on the display of approx. 1% for 10 minutes after the power supply is turned on. Perform settings suitable for the operating conditions. Incorrect setting can cause operation failure. For details of each setting, refer to the Operation Manual of the pressure switch.

(Initial conditions) 200 0.05 32 SFE1 SFE3 Inlet pressure/Back pressure [MPa] 150 SFE5 0.04 25 100 SFE4 SFE7 95 20 0.03 50 10 0 0.02 0 100 200 300 400 500 600 700 800 Cylinder driving speed [mm/s] AN 0.01 AMC Example) Bore size: 32, Driving speed: 400 mm/s, Supply pressure: 0.5 MPaG 1. From the graph, exhaust flow rate is found to be 95 L/min (ANR). 2.

ACB ACB SYJ 2-4.5 (Mounting hole) SX 57.5 VK 52.5 51 3(R) 1(P) 3(R) 1(P) VZ 9 16 32 17 4 VF VFR 10 4 10 P=11 L2 VP7 36.5 41.5 L1 VP4 45 M plug connector (M) VQ D side U side VQ4 Stations 1 2 3 4 5 n Direct manual override VQZ (Non-locking) 2n-C4, M5 (A, B port) C4: 4 One-touch fitting M5: M5 thread VQD VZS 2(B) 2(B) 27.5 VFS 20 15 4(A) 4(A) 5 VS 46 12.5 P=11 VS7 L plug connector (L) n: Station

DC24 V10% DC24 V10% DC(+) DC(-) 8 / / 9 () 10 / 5 m / 11 10 1015 "-M" ( ) (kPaMPa) "-M" 12 SI kPa,MPa -49NO.ZK2-OM00801-B No. 13 14 A () 15 () / ( ) () -50NO.ZK2-OM00801-B 80mA 3.5 F.S. 1 1 F.S. -51NO.ZK2-OM00801-B 100.0-100.0 kPa 105.0-105.0 kPa 500 kPa 0.1 kPa DC24 V 10(p-p)10() 40 mA NPN PNP OUT1OUT2 80 mA DC26.4 V 2 V (80 mA ) 2.5 ms (20,100,500,1000,2000 ms ) 0.2F.S

mounted 1(P) port 3/8 3(R) port 3/8 2(A) port 3/8 2 to 20 stations VPA500 P. 1569 VV3PA5-42 Individual EXH 1(P) port 3/8 3(R) port 3/8 2(A) port 3/8 VV3PA7-41 Common EXH 1(P) port 1/2 3(R) port 1/2 2(A) port 1/2 2 to 20 stations VPA700 VV3PA7-42 Individual EXH 1(P) port 1/2 2(A) port 1/2 3(R) port 1/2 Note) Supply pressure to 1(P) ports and exhaust air from 3(R) ports on both sides for 10

Refer to the drawing below. : Factory default setting is 32. Source/PNP (negative common) Output type 32 outputs (selected from 16 or 32 outputs) Number of outputs Output No. assignment The Output number is assigned by the SI unit.

25 to 1000 Lube Non-lube Air-hydro 1/2 M30 X 1.5 50 47 75 15 31 161 128 M14 X .5 36 90 43 14 16 32 17 59 35 36 28 to 1000 3/4 M36 X 1.5 56 53 80 36 18.5 17 182 144 M16 X 1.5 20 40 90 59 43 14 39 36 40 32 to 1200 3/4 M40 X 1.5 60 63 41 90 115 18.5 204 162 M18 X 1.5 20 17 23 45 70 48 39 44 50 40 to 1200 3/4 1 Lube Non-lube M45 X 1.5 60 63 90 115 18.5 46 20 226 182 M20 X 1.5 17 50 48 44 25

force N (maximum static load) Non-rotating Rod Accuracy W 25 1 32 0.8 40 0.5 50 0.5 Size Non-rotating rod accuracy Standard Strokes Size Standard stroke (mm) 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 75, 100, 125, 150, 175, 200, 250, 300 Max. manufacturable stroke 25, 32, 40, 50 300 Strokes other than the above are produced upon receipt of order.