SMC Corporation of America
Elite Part Number Search
Search Results "ISE20-P-P-N01-Y"

Series: 25A-ISE20, Rated Pressure Range: -0.1 TO 1 Mpa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -

This is a legacy product, and replaced byZH10BSA-N01-N01, VACUUM EJECTOR, VACUUM SERIES, ZH VACUUM EJECTOR, CC, ZH NOZZLE SIZE 1.0, .12320 lb

Analog Output p. 17 IO-Link: Process Data p. 17 Functions p. 17 Internal Circuits and Wiring Examples p. 18 Dimensions p. 20 7 3-Screen Display High-Precision Digital Pressure Switch ZSE20(F)/ISE20 Series IP65 2 outputs ZSE/ISE20B p. 13 IP65 2 outputs ZSE/ISE20C p. 24 IO-Link IP65 1 output ZSE/ISE20B-L p. 15 Air General fluids For vacuum pressure For compound pressure For positive pressure

Symbol: 09R6 (2 Port, N.C., Port 1 In, Port 3 Out), Function: Y (Plug Connector), Voltage: 5 (24VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Lead Wire Length: KO (Plug Connector, w/o Connector), CE Compliant: Q (CE Compliant)

Symbol: 09R6 (2 Port, N.C., Port 1 In, Port 3 Out), Function: Y (Plug Connector), Voltage: 5 (24VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Lead Wire Length: KOZ (Plug Connector, w/o Connector), CE Compliant: Q (CE Compliant)

Symbol: 09R6 (2 Port, N.C., Port 1 In, Port 3 Out), Function: Y (Plug Connector), Voltage: 6 (12VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Lead Wire Length: KO (Plug Connector, w/o Connector), CE Compliant: Q (CE Compliant)

Symbol: 09R6 (2 Port, N.C., Port 1 In, Port 3 Out), Function: Y (Plug Connector), Voltage: 6 (12VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Lead Wire Length: KOZ (Plug Connector, w/o Connector), CE Compliant: Q (CE Compliant)

Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Option: None, Lead Wire Length: 10 (1000mm)

Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Option: None, Lead Wire Length: 6 (600mm)

Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Option: None, Lead Wire Length: 10 (1000mm)

Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Option: None, Lead Wire Length: 6 (600mm)

Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Option: None, Lead Wire Length: 10 (1000mm)

Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Option: None, Lead Wire Length: 6 (600mm)

Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 6 (12 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Option: None, Lead Wire Length: 10 (1000mm)

Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 6 (12 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Option: None, Lead Wire Length: 6 (600mm)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Option: None, Lead Wire Length: 10 (1000mm)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Option: None, Lead Wire Length: 6 (600mm)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Option: None, Lead Wire Length: 10 (1000mm)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Option: None, Lead Wire Length: 6 (600mm)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Option: None, Lead Wire Length: 10 (1000mm)