SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ3-41-11-M5"

Model MQR1-M5 MQR2-M5 MQR4-M5 MQR8-M5 MQR12-M5 Number of circuits 1 2 4 8 12 Operating fluid Air / Inert gas Seal structure Metal seal Guide structure Bearing supported Bearing supported at both ends Port size Male R1/8 Female M5 x 0.8 M5 x 0.8 Flow rate C[dm3/(s.bar)] b Cv characteristics 0.50 0.40 0.17 Lubrication Not required Min. operating pressure -100kPa Max. operating pressure 1.0MPa

With One-touch fitting Port size M3 M3 x 0.5 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 Thread type M5 Metric thread (M3, M5) Unified thread (10-32 UNF) R NPT AS U10/32 01 02 03 04 Nil ASP N ASN Needle Valve/Flow Characteristics AQ AS1201F-M3, AS1211F-M3 AS1301F-M3, AS1311F-M3 AS1201F-M5-02, AS1211F-M5-02 AS1201F-M5, AS1211F-M5 AS1301F-M5, AS1311F-M5 AS2201F-01, AS2211F-01 AS2301F-01, AS2311F-01

VCHC AS1201F-M3, AS1211F-M3 AS1301F-M3, AS1311F-M3 AS1201F-M5-02, AS1211F-M5-02 AS1201F-M5, AS1211F-M5 AS1301F-M5, AS1311F-M5 AS2201F-01, AS2211F-01 AS2301F-01, AS2311F-01 ASS Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa ASR ASQ Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Number of needle rotations Number of needle rotations Number of

P PL M ML C H D L XT661-4C-X321 M5 x 0.8 5 M4 x 0.7 8 32 6 39 XT661-6C-X321 M5 x 0.8 6 M4 x 0.7 6 47 11 59 XT661-8C-X321 M5 x 0.8 6 M4 x 0.7 6 47 17 79 XT661-10C-X321 Rc 1/8 M4 x 0.7 6 47 23 99 XT661-120E-X322 Rc 1/8 M5 x 0.8 7 72 30.5 120 XT661-150E-X322 Rc 1/8 M5 x 0.8 7 72 37.5 150 744 Non-contact Gripper XT661 Series Dimensions [Bernoulli Type] With guide assembly Size: 120 Size

For details about auto switches with pre-wire connector, refer to page 7-9-36. 7-6-2 3 Series CQ2 Compact Cylinder: Standard Type Double Acting, Single Rod Type 12 40 20 50 16 25 63 32 80 100 Bore size (mm) Through-hole (Standard) Mounting Both ends tapped style Built-in magnet Pneumatic Air-hydro (1) M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/4 Rc 1/4 Rc 3/8 Rc 3/8 M5 x 0.8 M5 x 0.8 M5 x 0.8 M5 x 0.8 Screw-in

Type AS1200-M3 Direct cylinder elbow type 2 Bore size JIS Symbol Direct cylinder flat elbow type 4 Symbol Bore size Applicable series Control type AS1200-M3 AS1400-M3 M3 M3 x 0.5 Meter-out Meter-in 0 1 AS120-M5 AS120-U10/32 AS220-01 AS220-02 AS320-03 AS420-04 M5 x 0.8 10-32UNF 1/8 1/4 3/8 1/2 M5 U10/32 01 02 03 04 P.15-11-3 Thread type Cylinder side R Tube side Rc Symbol Metric thread (M3

Troubleshooting P.11 to 12 9. Construction and operating principle -P.13 10. Operating principle P.13 11. Sensor mounting (leakage sensor) P.14 1 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.

Looseness of bolts which fix the parts at each port (port, elbow fixing flange, port fixing flange, air port cover). 11 9.

Dimensions --11 7. Guaranteed term and guaranteed range 12 8. Parts replacement procedure 13 1 XL-OMP0001 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.

Model Thread size Tightening torque SX3000 M2 0.17 Nm SX5000 M3 0.8 Nm SX7000 M4 1.4 Nm 11 SX3000-OMM0002-B -12-SX3000-OMM0002-B -13SX3000-OMM0002-B TROUBLESHOOTING Should any trouble be found during operation, trace the source of the trouble in the following order and take corrective action.

The use of screws that are too long can touch the body and cause malfunction. 11. Do not operate by fixing the table and moving the actuator body. 12. The belt drive actuator cannot be used for vertically mounted applications. 13. Vibration may occur during operation, this could be caused by the operating conditions.

Order for tightening mounting screws 11 2-9-2. Auto switches When an auto switch is mounted or its set position is changed, refer to Fig. 4 to 11. C a u t i o n Use a specific mounting bracket (Page 19, Table 2) . Tighten mounting screws to the appropriate torque. The auto switch can only be used for cylinders with a built-in magnet for auto switch (e.g. CDA).

34.9 63.7 58.3 22 1/4" 13.2 59 7.4 31.3 60.1 54.7 17 20.9 12 AS3001F-09-3 AS4001F-10-3 82 11.3 35 69.3 61 21 18.5 64.4 8.2 5/16" 21 15.2 32.1 3.5 60.9 55.5 18 10 18.5 16 27 24.5 21 3.5 AS3001F-11-3 AS4001F-12-3 36 70.3 62 22 70.8 3/8" 17.2 33.3 62.1 56.7 21 9.5 12 20.9 AS4001F-11-3 76.9 3/8" 27 21 17.9 34.9 3.5 69.2 60.9 21 10.3 24.5 AS4001F-13-3 21.7 1/2" 83.1 36.3 11.6 70.6 62.3 22 15-

Refer to pages 5-11-2 to 6 for Safety Instruction and Solenoid Valve Precautions. Piping port (main) Top mounting For manifold Caution 1. Each valve is fixed on the manifold with two M4 mounting screws. Please tighten the screws properly when valves are reassembled. Screw tightening torque: 1.4 Nm 2.

Refer to front matters 42 and 43 for Safety Instructions and pages 3 to 11 for Actuator and Auto Switch Precautions. Selection Caution Mounting Caution Operate loads within the range of the operating limits. Select a model taking into consideration the allowable horizontal loads, rotational torque and eccentric loads that will apply.

0 (Set no. for 9, 10 & 11) Suction filter PE End cover e !1 When ordering a vacuum pressure gauge or a digital vacuum pressure switch separately, use the part numbers shown in the option specifications on page 13-7-5.

Lead wire length symbols: 0.5 m Nil (Example) Y69A 3 m L (Example) Y69AL 5 m Z (Example) Y69AZ Since there are applicable auto switches other than the listed above, refer to page 9-11-29.

Repeatability Maximum operating frequency 11-: Fluorine grease 22-: Lithium soap based grease 11-/22-: Class 3 Grease Cleanliness class (ISO class) 932