G PPA AL 14-12-3 4 Compact Manometer Series PPA PPA100/101/102 How to Order Unit specifications PPA10 0 M Pressure specifications Nil M Option/Case holder With the unit switching function(1) 0.1 to 1 MPa (For high pressure) 101 to 10 kPa (For vacuum) 10 to 100 kPa (For low pressure) 0 1 2 Fixed in SI unit (2) None With PPA-B Nil B Note 1) With unit switching function is not permitted to sell
Ejector stations Port & silencer position 1 station 01 Right side Left side Both sides R L S 10 stations (Max.) 10 Note) Left and right as viewed with the VAC port in front Thread type Common exhaust port size 1/2 3/4 ZZMA dedicated silencer (ZZM-SA) 04 06 S Rc NPTF G Nil T F When placing an order, include the single type ejector models to be manifolded together with the manifold part
G PPA AL 14-12-3 4 Compact Manometer Series PPA PPA100/101/102 How to Order Unit specifications PPA10 0 M Pressure specifications Nil M Option/Case holder With the unit switching function(1) 0.1 to 1 MPa (For high pressure) 101 to 10 kPa (For vacuum) 10 to 100 kPa (For low pressure) 0 1 2 Fixed in SI unit (2) None With PPA-B Nil B Note 1) With unit switching function is not permitted to sell
ambient humidity 35 to 95%RH Lever RSG Residual voltage Note 1) 3 V or less Withstand voltage Note 2) Lever detection switch 1000 VAC RS2H RS2H Endurance 10 to 55 Hz, Double amplitude 1.5 mm X, Y, Z direction each 2 h Vibration RSH Tightening nut Endurance 500 m/s2 (approx. 50 G), X, Y, Z direction each 10 times MIW MIS Impact IEC standards IP67 (Immersion proof and oil proof by JEM standards
-2No.PS-OMF0005CN-E / 1 1.5 *3) 1 1 [] -3No.PS-OMF0005CN-E () () -4No.PS-OMF0005CN-E () * 5 m -5No.PS-OMF0005CN-E * (RcNPTG) 1/8 79 Nm 1/4 1214 Nm 1.52 2 * () ()() () () -6No.PS-OMF0005CN-E * IP66IP65 () 060 (5 ) * -7No.PS-OMF0005CN-E (ISA2 ) * * (EXH) 5 m 0.2 MPa CE (2 VCA ) () C-R () ()C-R ( ) () AC 10 DC 2 * * 2 0.51.25 mm -10+10 5 -8No.PS-OMF0005CN-E *
As a guide, insert bolts in 2 positions for 2-5 stations, 3 positions for 6-10 stations, 4 positions for 11-15 stations, 5 positions for 16-20 stations and 6 positions for 21-24 stations. Take the same measures for horizontal mounting if the mounting surface vibrates. 2.
Setting range: 1 to 99 (10 dec.) Example: Example: 2 Address is set in network by using ET200 hand held unit or PG (programing tool). Once address is set, it is saved even if power is cut. Setting range: 1 to 125 (10 dec.) Value set on shipment: 125. CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.
Round cutting pliers Nominal: 125 or 150 Tightening torque: 1.4 0.1 Nm 10) Mount the bowl assembly. Hold the bowl assembly by hand and rotate clockwise. Do not use tool for mounting because the bowl may be damaged. Refer to the Check item for referential tightening torque. Actuators Modular F.R.L.
Direct acting guide 3 0.03 Ball screw 100 Matsushita Electric Industrial Co., Ltd. 50 Series LXP 6 100 Ball bushing guide Mitsubishi Electric Corporation Ball screw 0.03 50 5 Yaskawa Electric Corporation 100 Series LXS 50 10 Note) Series LXF is only compatible with motors manufactured by Mitsubishi Electric Corporation.
Series TUH Standard Type Hard Polyurethane Series P 20m bundle m 100m bundle TUH1073 TUH0858 TUH0644 TUH0428 TUH1288 Model 10 8 6 4 12 O.D. mm 7.3 5.8 4.4 2.8 8.8 I.D. mm Black (B) White (W) Blue (BU) Translucent (N) Specifications Air Note 1) Fluid Max. operating pressure (at 20C) (68F) 0.8MPa (116 psi) Note 2) Min. bending radius mm 10 18 24 30 36 2R Burst pressure At a temperature of
Ejector stations Port & silencer position 1 station 01 Right side Left side Both sides R L S 10 stations (Max.) 10 Note) Left and right as viewed with the VAC port in front Thread type Common exhaust port size 1/2 3/4 ZZMA dedicated silencer (ZZM-SA) 04 06 S Rc NPTF G Nil T F When placing an order, include the single type ejector models to be manifolded together with the manifold part
2 10 2 23 PS PE Note) 1 indicates the dimension when bracket A is mounted.
The voltage variation must stay within the -10 to +10% range of the rated voltage.
Related Products Ambient and fluid temperature (C) Weight (g) Note) Bracket assembly Dust bag assembly 417 (436) ZH-BK1-20-A ZH-DB1-20-A 929 (990) ZH-BK1-30-A ZH-DB1-30-A 1847 (1966) ZH-BK1-40-A ZH-DB1-40-A 92 (101) ZH-BK1-10-A ZH-DB1-10-A Note) ( ): Weight including the bracket Flow Rate Characteristics ZH10-X185 ZH20-X185 ---7 ---7 1,800 800 Suction flow rate [L/min (ANR)] Note 1) Air consumption
No.SFOD-OML0002-A PRODUCT NAME Handheld Electrostatic Meter MODEL/ Series IZH10 Table of Contents Safety Instructions 2 Model Indication Method 6 Summary of Product parts 7 Definition and terminology 8 Assembly 9 Setting / Adjustment 10 Procedure 10 Function settings 11 Troubleshooting 14 Specification 17 Specifications 17 Characteristics graph (for reference) 17 Dimensions 18 -1No.SFOD-OML0002
If the total lifting height is required instead of the discharge pressure, a discharge pressure of 0.1 MPa corresponds to a total lift of 10 m. Selection procedures: 1. First mark the intersection point for a discharge rate of 15 L/min and a discharge pressure of 0.14 MPa. 2. Find the pilot air pressure for the marked point.
Period and scope of warranty The guaranteed period covers the period which finishes the earliest among 0.5 million operating cycles [with our durability test conditions], 18 months after shipping from us, and 12 months after starting the use of the product at your place or your customers place.
This is equivalent to a field in a radius of about 18 cm from a welding part using welding current of about 15000 amperes.
40 6.6 6 42 93 32 59.5 37.5 10 12 138 154 34 50 9 9 48 112 40 66 44 10 12 146 162 40 60 9 9 54 120 50 72 44 12 16 178 198 46 65 11 10 64 148 63 77 49 12 16 192 212 58 75 11 10 78 162 80 96.5 56.5 16 24 238 262 54 90 13.5 16 91.5 202 100 116 66 19 31 280 308 62 100 15.5 22 111.5 240 Caution Do not use this cylinder as a stopper.