For the -20°C (-15°C) specification, the atmospheric dew point reaches -20°C (-15°C) in about 10 minutes after air is supplied.
The low dew point type requires 30 to 60 minutes.
Series IDF*F refrigerated air dryers are larger units with improved ambient (113°F/45°C) and inlet (140°F/60°C) air temperatures. *** These units are not available for use in the United States or Canada *** 50/60 Hz operation ; Max. inlet air temperature: 140°F (60°C) ; Max. flow at rated conditions: 1,059 scfm (30m³/min (ANR) @50°F (10°C) PDP; Connections: R threads are standard on size
Series IDF*FS refrigerated air dryers are larger units with improved ambient (113°F/45°C) and inlet (140°F/60°C) air temperatures.
Cooling capacities: 2kW, 4kW, 8kW, 10kW; Circulating Fluid: 60% ethylene glycol aqueous solution; Temperature range setting: -10 to 90°C (2kW), -20 to 90°C (4, 8, 10kW); Temperature stability: ±0.1°C; Power supply requirement: 3-phase 200 VAC/50Hz or 3-phase 200~208 VAC/60Hz; Standards: CE, UL, RoHS, SEMI S2, S8, F47
Cooling capacities: 2kW, 4kW, 8kW, 10kW; Circulating Fluid: Fluorinert™ or GALDEN® (see catalog for compatibility); Temperature range setting: -10 to 90°C (2kW), -20 to 90°C (4, 8, 10kW); Note: Temperature range depends on fluorinated fluid choice; Temperature stability: ±0.1°C; Power supply requirement: 3-phase 200 VAC/50Hz or 3-phase 200~208 VAC/60Hz; Standards: CE, UL, RoHS, SEMI S2, S8
Series IDFA refrigerated air dryers feature improved ambient (113°F/45°C) and inlet (149°F/65°C) air temperatures as well as improved flow ratings over standard models.
Series IDF*F refrigerated air dryers are larger units with improved ambient (113°F/45°C) and inlet (140°F/60°C) air temperatures. *** These units are not available for use in the United States or Canada *** 50/60 Hz operation ; Max. inlet air temperature: 140°F (60°C) ; Max. flow at rated conditions: 1,059 scfm (30m³/min (ANR) @50°F (10°C) PDP; Connections: R threads are standard on size
Series IDF*FS refrigerated air dryers are larger units with improved ambient (113°F/45°C) and inlet (140°F/60°C) air temperatures.
Series IDFA refrigerated air dryers feature improved ambient (113°F/45°C) and inlet (149°F/65°C) air temperatures as well as improved flow ratings over standard models.
Cooling capacities: 2kW, 4kW, 8kW, 10kW; Circulating Fluid: Fluorinert™ or GALDEN® (see catalog for compatibility); Temperature range setting: -10 to 90°C (2kW), -20 to 90°C (4, 8, 10kW); Note: Temperature range depends on fluorinated fluid choice; Temperature stability: ±0.1°C; Power supply requirement: 3-phase 200 VAC/50Hz or 3-phase 200~208 VAC/60Hz; Standards: CE, UL, RoHS, SEMI S2, S8
Cooling capacities: 2kW, 4kW, 8kW, 10kW; Circulating Fluid: 60% ethylene glycol aqueous solution; Temperature range setting: -10 to 90°C (2kW), -20 to 90°C (4, 8, 10kW); Temperature stability: ±0.1°C; Power supply requirement: 3-phase 200 VAC/50Hz or 3-phase 200~208 VAC/60Hz; Standards: CE, UL, RoHS, SEMI S2, S8, F47
No.SFOD-OML0002-A PRODUCT NAME Handheld Electrostatic Meter MODEL/ Series IZH10 Table of Contents Safety Instructions 2 Model Indication Method 6 Summary of Product parts 7 Definition and terminology 8 Assembly 9 Setting / Adjustment 10 Procedure 10 Function settings 11 Troubleshooting 14 Specification 17 Specifications 17 Characteristics graph (for reference) 17 Dimensions 18 -1No.SFOD-OML0002
INR-244-831 3-1 Communication Format 3.3 Composition of Required Message (from master to the product) Refer to page 3-4 3.5 Explanation of Code for codes 1 to 10.
Correlation between input number and Input Block The total number of Input and Output blocks can not exceed 10. The maximum input point is 32.
When making drain exhaust piping, use piping with bore size 10 or larger than 10. Length should be shorter than 5m.