MDHR2-20, 30 MDHR2-10, 15 H H L L Auto switches of D-M9NV, D-M9PV and D-M9BV are used. Auto switches of D-M9N, D-M9P and D-M9B are used. Auto switches of D-M9NV, D-M9PV and D-M9BV are used. Max. Protrusion of Auto Switch from Edge of Body: L, H Max.
Reference dimensions of M5 x 0.8, R threads after installation.
Designation Description 1 FG Function earth 2 0 V 0 V for solenoid valve 3 24 V +24 V for solenoid valve 4 SI0 V for SI unit operation 5 SI+ +24 V for SI unit operation The power supply connector included as an accessory can be used to supply the power. Applicable wire for the power supply connector is AWG24 to AWG16 (0.2 to 1.5 mm2).
200 V 110 V 220 V 240 V 48 V 230 V 24 V 12 V 02 (1/4) 03 (3/8) 02 (1/4) 03 (3/8) Table (2) Solenoid Valve Option AC Note) Note) Seal material Body material/ Shading coil material Note Note) Guide pin material Main valve poppet Coil insulation type Option symbol Fixed sealant Nil C37 Stainless steel Stainless steel DC NBR NBR G Note 1) Option S, Z are not available as surge voltage suppressor
Y7PWV Y7BWV Relay, PLC IC circuit 5 V, 12 V 3-wire (PNP) 2-wire 12 V Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit 24 V Grommet 5 V, 12 V Diagnostic indication (2-color indication) Water resistant (2-color indication) 12 V 2-wire Y7BA Solid state switches marked with are produced upon receipt of order. 0.5 mNil (Example) Y59A 3 mL (Example) Y59AL 5 mZ (Example) Y59AZ Lead wire length
Apparent power (VA) Volt-ampere is the product of voltage (V) and current (A). Power dissipation (W): For AC , W = V/A cos. For DC, W = V/A. (Note) cos shows power factor. cos = 0.6 2. Surge voltage A high voltage which is momentarily generated in the shut-off unit by shutting off the power. 3.
, D-F9WV D-M9 , D-F9W D-A9V D-F9V D-M9N B P D-F9BA No. of auto switches 15 20 25 10 10 5 2 10 15 20 25 5 5 1 Consult P/A for shorter stroke lengths than indicated in the table.
O R T S I Z E 2 1/4 3 3/8 5 3/4 6 1 8 1 1/2 9 2 02 1/4 03 3/8 04 1/2 06 3/4 10 1 14 1 1/2 20 2 T H R E A D T H R E A D 1 Male 2 Female (Only NAMC220, 320, 520 Special Order Only) R(PT)* Remove (N) when ordering N NPT FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT, REQUEST CATALOG REFERENCE E5G
O nl y t rai ned personnel shoul d operat e pneum at i cal l y operat ed m achi nery and equi pm ent . Com pressed ai r can be dangerous i f an operat or i s unf am i l i ar w i t h i t . Assem bl y, handl i ng or repai r of pneum at i c syst em s shoul d be perf orm ed by t rai ned and experi enced operat ors.
O nl y t rai ned personnel shoul d operat e pneum at i cal l y operat ed m achi nery and equi pm ent . Com pressed ai r can be dangerous i f an operat or i s unf am i l i ar w i t h i t . Assem bl y, handl i ng or repai r of pneum at i c syst em s shoul d be perf orm ed by t rai ned and experi enced operat ors.
O nl y t rai ned personnel shoul d operat e pneum at i cal l y operat ed m achi nery and equi pm ent . Com pressed ai r can be dangerous i f an operat or i s unf am i l i ar w i t h i t . Assem bl y, handl i ng or repai r of pneum at i c syst em s shoul d be perf orm ed by t rai ned and experi enced operat ors.
Process Valve: 2 Port Valve For Flow Control VNB Series [Option] Electrical entry: D or DZ only. How to Order Pilot system option Seal material Body material option Nil V Standard Vacuum pilot type NBR seals FKM seals EPR seals Nil Standard A B C Bracket (valve size: 1/2/3/4.)
Weight g Model d T D1 H D2 D3 L1 L4 L2 L3 Min. Max.
1/8 12 13.5 18.5 16 17 18.5 21.0 19 32 18.2 18.5 R 1/4 17 35.4 29.4 34.4 40.4 34 36 Reference dimensions for M5 and R threads after installation. 20.0 Inch Size A L4 Model Weight (g) M1 d D2 L3 L2 D1 L1 H T Max.
KE D AS-FG AS-FP Rz 12.5 45 AS-FM 4. Once the fitting has been tightened, backing it out to its original position often causes the sealant to become defective. Air leakage will occur. 2. Use G external threads with G internal threads. AS-D How to distinguish between G, R and NPT threads AS-T For R, NPT thread R: Without slit NPT: With slit For G thread Step 5.
Material: L (Body: Stainless Steel 304; Gasket/O-ring: FKM), Element Length: A (ℓ250), Port Size R: 20 (2), Element Type: M (Micromesh, Stainless Steel 304/Epoxy Material), Nominal Filtration Accuracy: 10 μm, Element Seal Material: V (FKM)
Material: L (Body: Stainless Steel 304; Gasket/O-ring: FKM), Element Length: B [ℓ500 (ℓ250 x 2)], Port Size R: 10 (1), Element Type: S (Sintered Metal, Stainless Steel Material), Nominal Filtration Accuracy: 100 μm, Element Seal Material: V (FKM), Pressure Gauge: G2 [G46-10-02X3 (Stainless Steel at Wetted Parts)]
Material: L (Body: Stainless Steel 304; Gasket/O-ring: FKM), Element Length: B [ℓ500 (ℓ250 x 2)], Port Size R: 20 (2), Element Type: M (Micromesh, Stainless Steel 304/Epoxy Material), Nominal Filtration Accuracy: 10 μm, Element Seal Material: V (FKM)
Material: L (Body: Stainless Steel 304; Gasket/O-ring: FKM), Element Length: A (ℓ250), Port Size R: 10 (1), Element Type: S (Sintered Metal, Stainless Steel Material), Nominal Filtration Accuracy: 5 μm, Element Seal Material: V (FKM)
Material: L (Body: Stainless Steel 304; Gasket/O-ring: FKM), Element Length: B [ℓ500 (ℓ250 x 2)], Port Size R: 10 (1), Element Type: S (Sintered Metal, Stainless Steel Material), Nominal Filtration Accuracy: 5 μm, Element Seal Material: V (FKM)