33 34 G 24 25 H 30 40 J 36 46 K 6 9 M 45.5 50.5 N 69 76 VVXA31 VVXA32 17-3-108
Note 15) Standard lead wire length for pressure sensor is 3 m. Standard lead wire length with connector for switch for vacuum and the lead wire length for switch with energy saving function is 2 m. Note 16) Select C, L, L1, Y when the pressure sensor (P, T) is selected for t Pressure Sensor/Digital Pressure Switch for Vacuum Specifications.
Outside tube AC2A-F 1 Flower fin tube assembly C1220T Flower fin 2 Housing AC2A-F 3 Water chamber cover FC200 4 Replacement parts HAW2 HAW7 No.
Double Acting, Single Rod Series (N)CQ2 Ordering Information How to Order Port thread type Mounting threads Switch 12 to 25 M thread Rc NPT G One Touch Notes 4,5) Nil Metric North American Nil N Solid state switch (see page 181 for details) M9 TN TF F 32 to 100 A9 Reed switch Magnet Note 4) Bore sizes available for air-hydro type are 20 to 100.
Lube Unit Mounting thread M12 Float switch mounting position J (Bracket mounting dimensions) Panel (Option) Bracket (Option) A B C D E F G H J K L M N P Q R S Model Port size ALDU600-06 ALDU600-10 ALDU900-12 ALDU900-14 ALDU900-20 43 10 57 51 16 67 77 85 90 100 283 296 424 424 476 4 3 135 345 460 145 90 150 480 20 430 470 175 87.5 30 62.5 1 1 1 2 615 615 682 419.2 209 4 1 250 125 33.2 33.2
ZFA100 Port size Symbol Model A B 18 20 28 ZFA200 1 8 1 4 Manifold Pitch (Section F-F') Port size (The above diagram is for ZFA200) ZFA100 Port size Symbol Model A B 19 18 24 28 ZFA200 1 8 1 4 Number of manifold stations Symbol Single unit Note) Model 2 56 68 76 88 3 74 86 104 116 4 92 104 132 144 5 110 122 160 172 6 128 140 188 200 7 148 158 216 228 8 164 176 244 256 9 182 194 272 284 10
M Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G S 6.0 , 2 H 463.5 I 180 J 30 K 15 L 24 N 120 O 184 P 220 Q 110 R 18 460.5 AMG850 1 2 13 42 348 220 57.5 220 10 14-20-7
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Refer to pages 837 and 838 for the details of solid state auto switch with pre-wired connector. Auto switches are shipped together, (but not assembled).
ZS-10-5A-50 1 pc. 6 1A 36 VJ10 ZP 2 m (For 110 VAC) 2.5 m Lead wire length 6 Nil 3A 36 VJ10 SP 3 m 0.6 m 30 50 3 m 5 m ZCUK The asterisk () denotes the symbol for assembly. AMJ AMV Ejector System/Recommended Model (The models below will have shorter deliveries.)
(The default setting does not include arbitrary display.) 6 Display colour Output ON: Green/ Output OFF: Red (Linked to OUT1) 9 8 8 [F 0] Setting of the switching function of the pressure range, display unit and switch output specifications is completed. 4.5 4.5 [F 2] Setting of OUT2 Same setting as [F 1] OUT1. 28 Press the button between 1 and 3 sec.
F luid flow s from the suction port F L UID IN to the discharge port F L UID OUT . It takes a w hile for pulse attenuator to operate. pump also stops w hen ball valve is closed on the discharge side. A void stopping the pump for long hours, as this may prevent restart of the pump. C losing valve abruptly can generates surge, that considerably shortens the life of the pump.
Function selection mode seconds, to display [F 0]. Select to display the function to be changed [F ]. Press and hold the button for 2 seconds or longer in function selection mode to return to measurement mode. Thank you for purchasing an SMC ZSE20(F)/ISE20 Series Digital Pressure Switch.
Caution ZSE10(F) kPa Displayed in the case of an internal data error. P ISE10 System Error PSI ZSE10(F) Do not touch the terminals and connectors while the power is on. Otherwise electric shock, malfunction or damage to the product can result. Tube One-touch fitting [F 1] Setting of OUT1 After maintenance is complete, perform appropriate functional inspections and leak tests.
IDX-OM-W028-B Operation Manual PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDU22E-23(-C,L,R,T,V) IDU22E-30(-C,L,M,R,T) IDU37E-23(-C,L,R,T,V) IDU37E-30(-C,L,M,R,T) IDU55E-23(-C,L,R,T,V) IDU55E-30(-C,L,M,R,T) IDU75E-23(-C,L,R,T,V) IDU75E-30(-C,L,M,R,T) Please read this manual prior of using the air dryer. Keep the manual readily available for reference.
IDX-OM-W022-A PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDU8E-10(-C,K,L,M,R,S,T) IDU8E-20(-C,K,L,M,R,T) IDU11E-10(-C,K,L,M,R,S,T) IDU11E-20(-C,K,L,M,R,T) IDU15E1-10(-C,K,L,M,R,S,T) IDU15E1-20(-C,K,L,M,R,T) IDU8E-23(-C,K,L,R,T,V) IDU11E-23(-C,K,L,R,T,V) IDU15E1-23(-C,K,L,R,T,V) Please read this manual prior of using the air dryer. Keep the manual readily available for reference.
N06 NPT3/4 5/16(inch) N04 2xNPT1/2 6) 5 DC24V *1G JIS B0202 ISO1603 ISO1179 8) Z 7 L L 0.3(m) 11) A NPN LO B PNP M M 0.3(m) MO 12) 9) M SI (kPa) D P (:psi) E 10) 14 GN (G) B G *7ZL212 27mm ZL212 (2 /1 , 4 ) E (2 ) F (2 ) V (1 ) 13 G 2m) W (2m) 5 No.ZL3-OM00801-A 2. 2.1 (1/P) (2/V) ZL3 ZL6 (3/E) // / (G) (2/V) 2.2 ZL6 1 ZL6 (ZL6-SC1-A) 2), 6 No.ZL3-OM00801-A 3. 3.1
No.ZL3-OM00601-B 1.How to Order ZL3 M 06 1 K1 5 LO Z 1 E A M G 1 Without valve ZL3 M 06 1 K1 5 LO Z 1 E A M G 1 With valve Pressure switch ZL3 M 06 1 K1 5 LO Z 1 V A M W 1 with energy saving function 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) 13) 14) 1) Max. suction flow 2) Standard supply pressure 4) Exhaust specifications 3 300L/min(ANR) M 0.35MPa Nil Exhaust through silencer H 0.50MPa
IDX-OM-W029-B / Series IDU22E-23(-C,L,R,T,V) IDU22E-30(-C,L,M,R,T) IDU37E-23(-C,L,R,T,V) IDU37E-30(-C,L,M,R,T) IDU55E-23(-C,L,R,T,V) IDU55E-30(-C,L,M,R,T) IDU75E-23(-C,L,R,T,V) IDU75E-30(-C,L,M,R,T) URLhttps://www.smcworld.com/ English instruction manual can be downloaded from our URLhttps://www.smcworld.com/ SMC () * 1 ) JIS B8370 * 2 ) ISO4414 *1) ISO4414Pneumatic fluid power General
RSH20, 32 Graphq Graphw 1.0 RSH20 RSH32 0.9 Bore size 50, 63, 80/ = 0 Bore size 50, 63, 80/ = 0.1 Operating pressure P [MPa] 0.8 1300 1300 80 0.7 1200 1200 0.6 1100 1100 0.5 1000 1000 0.4 900 900 0.3 63 80 Load weight m [kg] Load weight m [kg] Load weight m [kg] Load weight m [kg] 0.2 800 800 50 0.1 700 700 600 600 0 500 100 200 300 400 63 Lateral load F [N] 500 500 50 400 400 RS1H50, 63,
Symbol Applicable switch Output specifications Lead wire length Nil Without valve unit 25 (L) Lead wire length 0.6 (3.0) m NPN output D1 D2 26 (L) Lead wire length 0.6 (3.0) m Analog output 65 (L) Lead wire length 0.6 (3.0) m PNP output Pilot valve specifications 27 (L) Lead wire length 0.6 (3.0) m NPN output D3 26 (L) Lead wire length 0.6 (3.0) m Analog output DC: 1W type (with light: 1.05W