Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting), Operation Manual: T (w/o Operation Manual, Calibration Certificate
T (w/o Operation Manual, Calibration Certificate)
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: T (w/o Operation Manual, Calibration Certificate)
X578 X579 X580 Rated pressure range 500 Pa 1.000 kPa 2.00 kPa 5.00 kPa 10.00 kPa Set pressure range (Refer to page 60) 525 Pa 1.050 kPa 2.10 kPa 5.25 kPa 10.50 MPa Withstand pressure 2.5 kPa 5 kPa 10 kPa 25 kPa 50 kPa Smallest settable increment 1 Pa 0.001 kPa 0.01 kPa 0.01 kPa 0.01 kPa Applicable fluid Air, inert gases and incombustible gases Power supply voltage 12 to 24 VDC 10%, ripple (p-p
Note 2) Operation is possible with a valve with small Cv value when the operation cycle is small. 12 How to Order P B 1 3 1 3 A S Female thread / Tube extension P B 1 3 1 3 A S With nut Port size Material of diaphragm Symbol Main fluid Pilot air Symbol Material of diaphragm connection size connection size Female thread 1 PTFE 01 Rc 1/8 N01 NPT 1/8 F01 G 1/8 Actuation Tube extension Symbol
This is a legacy product, and replaced byISE20B-Y-P-N01-W-X503, PRESSURE SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CB, ISE40/50/60 1/8 NPT VERSION, 2.86600 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift
This is a legacy product, and replaced byZSE20B-V-P-N01-W-X500, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, JD, ZSE40/50/60 1/8 PORTED, .17416 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
This is a legacy product, and replaced byZSE20-P-N01-L, SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, JD, ZSE30 1/8 PORTED, .26179 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureMinimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--RepeatabilityHystere- sisAnalog outputDisplayDisplay accuracyIndicator lightEnviron- ment resistanceTemperature
This is a legacy product, and replaced byZSE20-P-N01-L, SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, JD, ZSE30 1/8 PORTED, .19453 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureMinimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--RepeatabilityHystere- sisAnalog outputDisplayDisplay accuracyIndicator lightEnviron- ment resistanceTemperature
This is a legacy product, and replaced byISE20B-Y-P-N01-W, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CB, ISE40/50/60 1/8 NPT VERSION, .26455 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
This is a legacy product, and replaced byISE20B-X-P-N01-W, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CB, ISE40/50/60 1/8 NPT VERSION, .21220 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
This is a legacy product, and replaced byZSE20B-Y-P-N01-W, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, JD, ZSE40/50/60 1/8 PORTED, .17416 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (at NPN output)1 V or less2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)0.6 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 2.4 to 20 mA ?2.5% F.S.?
PSE530 PSE531 PSE532 PSE533 Rated pressure range 0 to 1 MPa 0 to -101 kPa 0 to 101 kPa -101 to 101 kPa Extension analog output range -0.1 to 0 MPa 10.1 to 0 kPa -10.1 to 0 kPa Withstand pressure 1.5 MPa 500 kPa Applicable Air, inert gases and incombustible gases Power supply voltage 12 to 24 VDC10%, ripple (p-p) 10% or less (Protected against inverse connection) Current consumption 15 mA
Model no. of NPT thread is AN101N01 and AN110-N01. Note 2) It indicates the inlet pressure for solenoid valve. Note 3) It can operate in temperatures between 10 to 150C if there is no risk of the moisture in the air freezing. VEX Refer to page 5-10-13 for Precautions on these products.
/O.D. mm Symbol 01 02 03 04 N01 N02 N03 N04 Symbol 07 09 11 13 Applicable tube O.D. mm 6 8 10 12 1/4" 5/16" 3/8" 1/2" Symbol 50 60 65 80 85 110 5/8 6/9 6.5/10 8/12 8.5/12.5 11/16 Metric size The figures in ( ) indicate the internal diameter of the applicable hose. Inch size 1
10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (at NPN output)1 V or less2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)0.6 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 2.4 to 20 mA ?2.5% F.S.?
10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (at NPN output)1 V or less2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)1 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 4 to 20 mA ?2.5% F.S.?
10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (at NPN output)1 V or less2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)0.6 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 2.4 to 20 mA ?2.5% F.S.?
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A2 (Bracket B, Horizontal Mounting), Option 3: K (Operation Manual, Calibration Certificate)