This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA, VALVE, VX3 3-WAY MEDIA VALVE, GA, VX3 BODY PT 3/8NPT, 1.46965 lb, ModelOrifice dia.Port size1.5 mm?2.2 mm?3 mm?4 mm?VX32?------1/43/8
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA, VALVE, VX3 3-WAY MEDIA VALVE, GC, VX3 BODY PT 3/8NPT, 1.55027 lb, ModelOrifice dia.Port size1.5 mm?2.2 mm?3 mm?4 mm?VX33?------1/43/8
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA, VALVE, VX3 3-WAY MEDIA VALVE, GC, VX3 BODY PT 3/8NPT, 1.68510 lb, ModelOrifice dia.Port size1.5 mm?2.2 mm?3 mm?4 mm?VX33?------1/43/8
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA, VALVE, VX3 3-WAY MEDIA VALVE, GC, VX3 BODY PT 3/8NPT, 1.41095 lb, Port sizeOrifice diameter (mm?)ModelMax. operating pressure differential (MPa)Flow characteristicsMax. system pressure (MPa)Note)Weight (g) COM.Av x 10-6m2Cv converted3/8 (10A)3/8 (10A)3VX3234-030.37.90.331.0530
The VX3000 series is a direct operated, 3 port solenoid valve, for use with a wide variety of fluids. When used in combination with the manifold, configuration can be changed from N.C. to N.O. and from N.O. to N.C. by simply changing a gasket. Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure
SMC's series VXK21/22/23, 2-port solenoid valve was designed with a Y type strainer installed inside the body to remove foreign materials mixed in fluids before they?enter the actuating part of the valve (armature), as well as preventing the flow of foreign materials?to downstream equipment.? This unique filter design improves valve performance, stops leakage, and ensures longer valve life
The VX3000 series is a direct operated, 3 port solenoid valve, for use with a wide variety of fluids. When used in combination with the manifold, configuration can be changed from N.C. to N.O. and from N.O. to N.C. by simply changing a gasket. Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure
SMC's series VXK21/22/23, 2-port solenoid valve was designed with a Y type strainer installed inside the body to remove foreign materials mixed in fluids before they enter the actuating part of the valve (armature), as well as preventing the flow of foreign materials to downstream equipment. This unique filter design improves valve performance, stops leakage, and ensures longer valve life
The VQC series has five standard wiring packages bringing a world of ease to wiring and maintenance work, while the protective enclosures of three of them conform to IP67 standards for protection from dust and moisture. The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration. The VQC series has
The VQC series has five standard wiring packages bringing a world of ease to wiring and maintenance work, while the protective enclosures of three of them conform to IP67 standards for protection from dust and moisture. The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration. The VQC series has
The VQC series has five standard wiring packages bringing a world of ease to wiring and maintenance work, while the protective enclosures of three of them conform to IP67 standards for protection from dust and moisture. The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration. The VQC series has
VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal
Dispense Volume: 3 (100 to 200 μL), Type: 1 (Body Ported), Voltage: 5 (24 VDC), Fluid Contact Material: C (Body: PP; Diaphragm: EPDM; Check Valve: EPDM), Port Size: 1 (M5)
Symbol: 105R (Base Mounted, 3 Port, Universal), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1 (PVDF, M6)
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1 (PVDF, M6)
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1 (PVDF, M6)
Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1 (PVDF, M6)
Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1 (PVDF, M6)
Symbol: 155R (3 Port, Universal), Function: HY (High-pressure w/Power Saving Circuit), Voltage: 5 (24VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material/Port Size/ Reverse Mounting Prevention Pin: 1 (M6, PVDF)
Symbol: 15R4 (2 Port, N.O., Port 3 IN, Port 2 OUT), Function: HY (High-pressure w/Power Saving Circuit), Voltage: 5 (24VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material/Port Size/ Reverse Mounting Prevention Pin: 1 (M6, PVDF)