SMC Corporation of America
Elite Part Number Search
Search Results "VV5Q21-04N7FS0-RS"

Joint 7 9 YB-03 32, 40 11.5 depth 7.5 34 25 12 K ( across flats) H (With locking) 9 11 YB-05 50, 63 42 32 12 14.5 depth 8.5 11 13 YB-08 80 52 38 16 18 depth 12 d2 d1 14 17 YB-10 100 62 50 19 21 depth 14 L UT C UA Bore size (mm) T1 RS Weight (g) T2 V W Part no. Part no.

YB-03 32, 40 12 7 25 9 34 11.5 depth 7.5 Joint YB-05 50, 63 12 9 32 11 42 14.5 depth 8.5 K ( across flats) H (With locking) Weight (g) Bore size (mm) RS T1 T2 V W Part No. YB-03 32, 40 80 9 6.5 10 18 50 d2 d1 YB-05 50, 63 120 11 6.5 12 22 60 L UT C UA (mm) Part No.

Fan cooled internal power supply ; Front panel includes display and input panel, and power switch ; Connectors for heat exchanger, alarm output, communication, and power located at rear ; Compatible with RS-485 or RS-232C

Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacities (W): 1100/300, 1200/500, 1800/500, 2400/700, 3000/700, 5100/1200; Temperature stability: ±0.1°C; Power supply requirement: 200~230 VAC, 50/60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards

Fan cooled internal power supply ; Front panel includes display, LEDs and power switch ; Connectors for tank, alarm output, communication, and power located at rear ; Compatible with RS-485 or RS-232C

Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacities (W): 1100/200, 1200/500, 1800/500, 2400/700, 3000/700, 5900/1200; Temperature stability: ±0.1°C; Power supply requirement: 200~230 VAC, 50/60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards

Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C/RS-485 Communication functions; Cooling/Heating capacities: 950W/430W, 1200W/400W, 1800W/400W; Temperature stability: ±0.1°C; Power supply requirement: 100 VAC (50-60Hz), 115 VAC (60 Hz); Circulating Fluid: water or 15% ethylene glycol; Standards: CE, C-MET-US/UL

Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C/RS-485 Communication functions; Cooling/Heating capacities: 860W/480W, 1200W/400W, 1800W/400W; Temperature stability: ±0.1°C; Power supply requirement: 100 VAC (50-60Hz), 115 VAC (60 Hz); Circulating Fluid: water or 15% ethylene glycol; Standards: CE, C-MET-US/UL

Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacity (W): 5900/1200; Temperature stability: ±0.1°C; Power supply requirement: 380-415VAC, 50/60Hz, or 460~480Vac, 60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards: CE, RoHS

Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacity (W): 5900/1200; Temperature stability: ±0.1°C; Power supply requirement: 380-415VAC, 50/60Hz, or 460~480Vac, 60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards: CE, RoHS

Fan cooled internal power supply ; Front panel includes display, LEDs and power switch ; Connectors for tank, alarm output, communication, and power located at rear ; Compatible with RS-485 or RS-232C

Fan cooled internal power supply ; Front panel includes display and input panel, and power switch ; Connectors for heat exchanger, alarm output, communication, and power located at rear ; Compatible with RS-485 or RS-232C

Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacities (W): 1100/300, 1200/500, 1800/500, 2400/700, 3000/700, 5100/1200; Temperature stability: ±0.1°C; Power supply requirement: 200~230 VAC, 50/60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards

Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacities (W): 1100/200, 1200/500, 1800/500, 2400/700, 3000/700, 5900/1200; Temperature stability: ±0.1°C; Power supply requirement: 200~230 VAC, 50/60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards

Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C/RS-485 Communication functions; Cooling/Heating capacities: 950W/430W, 1200W/400W, 1800W/400W; Temperature stability: ±0.1°C; Power supply requirement: 100 VAC (50-60Hz), 115 VAC (60 Hz); Circulating Fluid: water or 15% ethylene glycol; Standards: CE, C-MET-US/UL

Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C/RS-485 Communication functions; Cooling/Heating capacities: 860W/480W, 1200W/400W, 1800W/400W; Temperature stability: ±0.1°C; Power supply requirement: 100 VAC (50-60Hz), 115 VAC (60 Hz); Circulating Fluid: water or 15% ethylene glycol; Standards: CE, C-MET-US/UL

Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacity (W): 5900/1200; Temperature stability: ±0.1°C; Power supply requirement: 380-415VAC, 50/60Hz, or 460~480Vac, 60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards: CE, RoHS

Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacity (W): 5900/1200; Temperature stability: ±0.1°C; Power supply requirement: 380-415VAC, 50/60Hz, or 460~480Vac, 60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards: CE, RoHS