SMC Corporation of America
Elite Part Number Search
Search Results "VV2Q22-05-DO-00N"

Safety Instructions Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.

Z\Warning 1.Do not drop or cause impact to $witch. Do not drop, apply excessive impact (more than 300m/s2 for reed switch, more than 1000m/s2 for solid-state switch) when handling. Damage could occur to the inside as well as the body. 2.Do not pull the lead wire wiih excessive force. Do not pull the lead wile to move the cylinder.

Safety Instructions Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.

Safety Instructions Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.

Do not drop or bump. 1. Avoid repeatedly bending or stretching lead wires. Do not drop, bump or apply excessive impacts (300ms or more for reed switches and 1000ms or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2.

Do not drop or bump. Do not drop, bump or apply excessive impacts (300m/s2 or more for reed switches and 1000m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.

If the tightening torque is insufficient, the mounting screws and brackets may become loose. 6) Do not directly touch the emitters with your finger or tools. Do not directly touch the emitter with your finger.

Consider a made-to-order product (-XC6) if the product is to be used in an environment where the generation of rust or corrosion will be a problem. 2) Do not expose the product to direct sunlight for an extended period of time. 3) Do not use in a place subject to heavy vibration and/or shock. 4) Do not mount the product in locations where it is exposed to radiant heat 5) Do not use in dusty

DO DS Without air cushion (mm) B Bore size (mm) No.

Do not use in direct sunlight. 10. Do not mount the product in locations where it is exposed to radiant heat. Caution 1. Do not use in an area where a magnetic field is generated. Auto switches will malfunction or magnets inside cylinders will become demagnetized. (Consult SMC regarding the availability of a magnetic field resistant auto switch.) 2.

Tube size AQ 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 03 05 07 09 11 13 ASV Body size AS1001F AS2001F AS2051F AS3001F AS4001F TMH-01J TMH-03J AK TMH-05 TMH-07 TMH-09 ASS TMH-11 TMH-13 Dimensions Model D2 D1 H1 H2 H3 H4 H5 L1 L2 L3 Symbol Metric Inch TMH-23J TMH-04J 1/8J 1/32J 3/16 6 1/4 8 5/16 10 3/8 12 1/2 8.4 9.3 11.7 11.6 13.1 13.5 15.5 18.5 18.8 21.2 22 TMH-01J TMH-03J TMH-05 3.3 4.5

Safety Instructions Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate or set with wet hands. This may lead to an electric shock. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.

Precautions Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate or set with wet hands. This may lead to an electric shock. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.

Hold/Release success: default output DO[101] Hold/Release failure: default output DO[102] * Digital output port can be selected within DO[101] to DO[112] * you select the same digital output port for different status signals, a warning message will be displayed. 2. Test run The manual operation of the magnet gripper unit can be checked.

Do not close any objects which are affected by magnets. Since magnets are built in cylinders, do not close magnetic disks, magnetic cards or magnetic tapes. The data may be destroyed. 7. Design circuit to prevent shooting out of a driven object.

Do not pull sensor cable strongly. Do not ground it with devices generating strong electromagnetic noise. Such action may cause failure. 4. Power supply line 4. Check wiring Do not mount any switch or relay to power supply line (12 VDC to 24 VDC). Incorrect wiring may cause damage or malfunction of the products. Make sure the wiring is correct before operation.

Also, do not apply external force to the fittings when binding tubes with bands, etc. (see Fig. 2.) 1. Do not use in an atmosphere having corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these. 2. Do not use in explosive atmospheres. 3. Do not use in locations subject to vibration or impact. 4.