Precautions FH150-02 to 04 q Mounting Confirm IN and OUT before mounting.
m P 0.1 x m + m P D 1.6 x D 5.0 x D 5.0 x m m mv P Pv m > mv P > Pv Determination of allowable load mass & pressure Inclined operation (Refer to page 8-16-8
Note 2) Refer to p.5.3-5 for lead wire length.
NARM 2500 05 A 02 G1 Optimal for central pressure control. Accessory Regulator for manifold Pressure easily set using the new handle. One-touch lock system.
The series and their stopping accuracy are as follows: CLJ series (p.3.1-10), CLM2 series (p.3.1-18), CLG1 (p.3.127), CLA series (p.3.1-35), and CL1 series (p.3.1-50). wWhen kinetic energy acts upon the cylinder, such as when effecting an intermediate stop: There are constraints in terms of the allowable kinetic energy that can be applied to the cylinder in a locked state.
Fittings & Tubing Air Cylinders Rotary Actuators How to Order Manifold 10 SS5Q13 08 FD2 D CE-compliant Clean series Nil Q CE-compliant Stations 1 station 01 1(P), 3(R) port size 24 Note) 24 stations Nil 1(P), 3(R) port 8 One-touch fittings 1(P), 3(R) port 5/16" One-touch fittings Note) The maximum number of stations depends on the type of electrical entries. 00T Option Nil 02 to 24 Note
P. 2-3-44 P. 2-3-46 P. 2-3-47 P. 2-3-48 C6 L6 P R D side SMC AN200 U side Individual EXH spacer SSQ1000-R-3Special wiring specifications (-K) Back pressure check valve (-B) SSQ1000-BP Built-in silencer (-S) P. 2-3-49 P. 2-3-45 P. 2-3-46 P. 2-3-47 C6 L6 D-sub connector Terminal no.
(P.23) 10.1 (P.33) 3.4 (P.16) 11.(P.42) (CN1: EMG 3.(P.12) ) INP ON 10.1 (P.33) (INP PLC ) 5 3.(P.12) PLC (PLC) 2 12.4 (P.50) 11.(P.42) 3.(P.12) 83 - 5.(P.23) 10.1 (P.33) 3.(P.12) PLC (PLC) 2 12.4 (P.50) () () (LED() 3.2 (P.13) ) 11.(P.42) 5 11.(P.42) 11.(P.42) 3.(P.12) (CN1: EMG 3.
(For B: Basic) CM2 Bore size GA P Bore size GA P 20 14 M5 x 0.8 50 (14) (Rc 1/4) 25 13 M5 x 0.8 63 (14) (Rc 1/4) 32 (12) (Rc 1/8) 80 (20) (Rc 3/8) 40 (13) (Rc 1/8) 100 (20) (Rc 1/2) 2 x P GA CM3 CG1 CG1 * When female thread is used, use a washer, etc. to prevent the contact part at the rod end from being deformed depending on the material of the workpiece. ( ): Same as the standard model.
For stopping accuracy, refer to Series CLJ (P. 9-2-12), Series CLM2 (P. 9-2-20), Series CLG1 (P . 9-2-30), and Series CL1 (P . 9-3-2) respectively. 7. In order to further improve stopping accuracy, the time from the stop signal to the operation of the lock should be shortened as much as possible.
For stopping accuracy, refer to Series CLJ (P. 9-2-12), Series CLM2 (P. 9-2-20), Series CLG1 (P . 9-2-30), and Series CL1 (P . 9-3-2) respectively. 7. In order to further improve stopping accuracy, the time from the stop signal to the operation of the lock should be shortened as much as possible.
P P 1 to 10 PFA30m P P P 5 to 50 P P P 10 to 100 31m P P P 20 to 200 P P P 50 to 500 P P P P 150 to 3000 P P P P 300 to 6000 P P P P 6000 to 12000 Series variations For Water Flow rate Remote type Output specification Port size (Rc, NPT, G) Integrated measurement display type Display unit Sensor unit Switch output 3/8 1/2 3/4 range l/min PFW31m 30m 32m PFW704 720 740 PFW504 520 540 P P
10 Micro Mist Separator AMD Series Standard Specifications p. 11 Flow Rate Characteristics p. 12 Activated Carbon Filter AMK Series Standard Specifications p. 19 Flow Rate Characteristics p. 20 AFF AM AMD Construction p. 21 Dimensions p. 23 Modular Connection Example p. 25 Accessories Sold Separately p. 27 International Standard ISO 8573-1:2010 p. 28 Specific Product Precautions
Model ZX1 J1 E P F Nil Vacuum switch (E) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Vacuum switch (ZSE2) ZX1-J1-E Adsorption confirmation switch (P) (Release to atmospheric pressure) Pressure sensor Spacer 1 (For side mounting) Manual override (Non-locking)
Silencer AN200-02 AN200-02 AN300-03 AN300-03 AN400-04 Caution on Pneumatic Circuit Design Air balance Unlike the current pneumatic cylinder that performs a simple reciprocal movement, the stroke reading cylinder with a brake also makes intermediate stops.
Optional Parts Clean Room Compliant (10-) 10-ARP20(K) 10-ARP30(K) 10-ARP40(K) Model Bracket assembly Note 1) ARP20P-270AS ARP30P-270AS ARP40P-270AS Set nut ARP20P-260S ARP30P-260S ARP40P-260S G49-4-01 G49-4-02 0.4 MPa G49-2-01 G49-2-02 0.2 MPa Round type Note 2) G49-7-01 G49-7-02 0.7 MPa Pressure gauge NPN output / Wiring bottom entry ISE35-N-25-MLA [ISE35-N-25-M (Switch body only)] NPN output
W Recommended Pneumatic Equipment CC Brake valve VFS21O VFS21O VFS21O VFS31O VFS31O Bore size (mm) Directional control valve VFS24OR VFS24OR VFS34OR VFS44OR VFS44OR Silencer AN200-02 AN200-02 AN300-03 AN300-03 AN400-04 Speed controller AS4000-02 AS4000-02 AS4000-03 AS420-03 AS420-04 Regulator AR425 AR425 AR425 AR425 AR425 Piping Nylon 8/6 or larger Nylon 10/7.5 or larger Nylon 12/9 or larger
Optional Parts Clean Room Compliant (10-) 10-ARP20(K) 10-ARP30(K) 10-ARP40(K) Model Bracket assembly Note 1) ARP20P-270AS ARP30P-270AS ARP40P-270AS Set nut ARP20P-260S ARP30P-260S ARP40P-260S G49-4-01 G49-4-02 0.4 MPa G49-2-01 G49-2-02 0.2 MPa Round type Note 2) G49-7-01 G49-7-02 0.7 MPa Pressure gauge NPN output / Wiring bottom entry ISE35-N-25-MLA [ISE35-N-25-M (Switch body only)] NPN output
Optional Parts ARP20(K) ARP30(K) ARP40(K) Model Bracket assembly Note 1) ARP20P-270AS ARP30P-270AS ARP40P-270AS Set nut ARP20P-260S ARP30P-260S ARP40P-260S G36-4-01 G46-4-02 Round type Note 2) 0.4 MPa Square embedded type Note 3) GC3-4AS [GC3P-010AS (Pressure gauge cover only)] G36-2-01 G46-2-02 Round type Note 2) 0.2 MPa Square embedded type Note 3) GC3-2AS [GC3P-010AS (Pressure gauge cover