Please contact us for the latest version.sales@ocaire.com, VALVE, BODY PORTED (AC), VALVE, VQZ3000 VALVE, SOL 4/5-PORT, EG, VQZ3000 BODY PORT (1/4 NPT), .28600 lb
Please contact us for the latest version.sales@ocaire.com, VALVE, BODY PORTED (DC), VALVE, VQZ3000 VALVE, SOL 4/5-PORT, EG, VQZ3000 BODY PORT (1/4 NPT), .40418 lb
(eg. protection cover) M2 W4 W1 YES NO NO Do not use since it will cause breakage of sensor or air leakage. Yaw moment M3 = W4 x L2 L2 YES Is there any influence of noise? (Refer to Caution on Handling on pages 6 and 7.) Install a noise filter.
The product may be damaged or malfunction if it is used outside of its specification range (eg. current load, voltage, temperature or impact, etc.). 2. Take precautions when multiple actuators are used close together. When two or more actuators are lined up in close proximity to each other, magnetic field interference may cause the switches to malfunction.
(eg. protection cover) M2 We We W4 m FE L3 L2 W1 L1 Note ) -X ME 1 3 ME = FEL1 = 0.05am L1 (Nm) YES NO 20NO Note) Average load coefficient (This coefficient is meant to average the maximum load moment at the time of impact with stopper in the light of calculating the service life.) Do not use since it will cause breakage of sensor or air leakage.
(eg. protection cover) M2 We We W4 m FE L3 L2 W1 L1 Note ) -X ME 1 3 ME = FEL1 = 0.05am L1 (Nm) YES NO 20NO Note) Average load coefficient (This coefficient is meant to average the maximum load moment at the time of impact with stopper in the light of calculating the service life.) Do not use since it will cause breakage of sensor or air leakage.
The product may be damaged or malfunction if it is used outside of its specification range (eg. current load, voltage, temperature or impact, etc.). 2. Pay attention to the length of time that a switch is on at an intermediate stroke position.
Valve Mounting: 1 (Screw Mount Type), Filter: F (w/Filter), Flow Rate/Operating Frequency: H (Flow 100 L/min; Power 4W; Max. Op Frequency 200Hz), Lead Wire: G (300 mm)
Valve Mounting: 1 (Screw Mount Type), Filter: F (w/Filter), Flow Rate/Operating Frequency: F (Flow 100 L/min; Power 40W; Max. Op Frequency 550Hz), Lead Wire: G (300 mm)
Valve Mounting: 1 (Screw Mount Type), Filter: F (w/Filter), Flow Rate/Operating Frequency: B (Flow 50 L/min; Power 40W; Max. Op Frequency 1000Hz), Lead Wire: H (500 mm)
Valve Mounting: 1 (Screw Mount Type), Filter: F (w/Filter), Flow Rate/Operating Frequency: F (Flow 100 L/min; Power 40W; Max. Op Frequency 550Hz), Lead Wire: J (1000 mm)
Valve Mounting: 1 (Screw Mount Type), Filter: F (w/Filter), Flow Rate/Operating Frequency: G (Flow 100 L/min; Power 10W; Max. Op Frequency 300Hz), Lead Wire: J (1000 mm)
Valve Mounting: 1 (Screw Mount Type), Filter: F (w/Filter), Flow Rate/Operating Frequency: H (Flow 100 L/min; Power 4W; Max. Op Frequency 200Hz), Lead Wire: J (1000 mm)
Valve Mounting: 1 (Screw Mount Type), Filter: F (w/Filter), Flow Rate/Operating Frequency: L (Flow 150 L/min; Power 10W; Max. Op Frequency 250Hz), Lead Wire: H (500 mm)
Valve Mounting: 1 (Screw Mount Type), Filter: F (w/Filter), Flow Rate/Operating Frequency: E (Flow 100 L/min; Power 80W; Max. Op Frequency 650Hz), Lead Wire: J (1000 mm)
Valve Mounting: 1 (Screw Mount Type), Filter: F (w/Filter), Flow Rate/Operating Frequency: K (Flow 150 L/min; Power 40W; Max. Op Frequency 500Hz), Lead Wire: J (1000 mm)
Valve Mounting: 1 (Screw Mount Type), Filter: F (w/Filter), Flow Rate/Operating Frequency: A (Flow 50 L/min; Power 80W; Max. Op Frequency 1200Hz), Lead Wire: G (300 mm)
Valve Mounting: 1 (Screw Mount Type), Filter: F (w/Filter), Flow Rate/Operating Frequency: A (Flow 50 L/min; Power 80W; Max. Op Frequency 1200Hz), Lead Wire: J (1000 mm)
Valve Mounting: 1 (Screw Mount Type), Filter: F (w/Filter), Flow Rate/Operating Frequency: B (Flow 50 L/min; Power 40W; Max. Op Frequency 1000Hz), Lead Wire: G (300 mm)
Valve Mounting: 1 (Screw Mount Type), Filter: F (w/Filter), Flow Rate/Operating Frequency: C (Flow 50 L/min; Power 10W; Max. Op Frequency 550Hz), Lead Wire: G (300 mm)