16 15 L 11 30.7 64 No.JXC-OMU0004-A 12.
U D side D B Special specification M U side 2 to 10 stations 15 15 Includes number of blanking plate assembly .
L Dimension n: Stations L n 2 135.5 125 102.6 16.5 63 3 148 137.5 113.1 17.5 73.5 4 148 137.5 123.6 12 84 5 160.5 150 134.1 13 94.5 6 173 162.5 144.6 14 105 7 185.5 175 155.1 15 115.5 8 198 187.5 165.6 16 126 9 210.5 200 176.1 17 136.5 10 210.5 200 186.6 12 147 11 223 212.5 197.1 13 157.5 12 235.5 225 207.6 14 168 13 248 237.5 218.1 15 178.5 14 260.5 250 228.6 16 189 15 273 262.5 239.1 17
C D 15, 20 (mm) Applicable switch model Bore size (mm) D-A9 D-F9, D-A9W A B C D A B C D 15 56.5 17.5 76.5 21.5 72.5 60.5 87.5 67.5 20 39.5 19.5 23.5 83.5 35.5 71.5 Note 1) Auto switches cannot be installed in Area C in the case of 15.
C D 15, 20 (mm) Applicable switch model Bore size (mm) D-A9 D-F9, D-A9W A B C D A B C D 15 56.5 17.5 76.5 21.5 72.5 60.5 87.5 67.5 20 39.5 19.5 23.5 83.5 35.5 71.5 Note 1) Auto switches cannot be installed in Area C in the case of 15.
11 7 52.8 0.016 0.043 MHZ2-16E 16f8 20 10 15 58.7 D2 0.020 0.053 MHZ2-20E 20f8 22 12 19 70.5 0.020 0.053 D1 MHZ2-25E 25f8 15 25 24 82.9 Other dimensions and specifications correspond to the standard.
11 7 52.8 0.016 0.043 MHZ2-16E 16f8 20 15 10 58.7 D2 0.020 0.053 MHZ2-20E 20f8 12 22 19 70.5 0.020 0.053 D1 MHZ2-25E 25f8 15 25 24 82.9 Other dimensions and specifications correspond to the standard.
(mm) Stroke (mm) Vacuum entry direction Vertical Male thread M18 x 1.5 M18 x 1.5 M22 x 1.5 (Rc, NPT, NPTF) 100, 125 25, 50, 75, 100 40 to 80 25, 50, 75 Mounting Connection ZX 40, 50 63, 80 100, 125 0 stroke 6.9 N 11.8 N Full stroke 0 stroke 10 N 15 N Full stroke Thread dia.
41.5 48 56 80 83 86.5 D-F7lWV 5 14 18 40 45 42.5 39.5 46 54 78 81 40.5 D-A9ll 3 12 16 38 43 81.5 46 52.5 60.5 84.5 87.5 91 D-F7NT 9.5 18.5 22.5 44.5 49.5 47 43.5 50 58 82 85 88.5 D-F9ll 7 16 20 42 47 44.5 42.5 49 57 81 84 87.5 D-F9lWl 6 15 19 41 46 43.5 4.4-16
When the temperature of the circulating fluid is set to lower than 10oC, use a 15% aqueous solution of ethylene glycol. Tap water may freeze in the thermo-chiller, leading to malfunction. 15% aqueous solution of ethylene glycol When a 15% aqueous solution of ethylene glycol is used, prepare the ethylene glycol aqueous solution separately.
25 10 15 25 240 350 310 10 Series Series CY1F CY1F 28 34 46 46 63 198 225 205 294 260 CY1H CY1H MY2H 39.5 For 100mm stroke cylinder Overall length reduced by 22% compared to Series MY2H Magnetically coupled rodless cylinder: Low profile guide Series CY1F: 10, 15, 25 4 types of stroke adjustment are available.
15 15 17 15 25 35 N 4 4 4 4 6 6 6 NA 2 2 2 2 2 4 4 GA 15 15 15 42 51 61 111 KA 125.5 179.5 HA 40 40 40 25 36 72 76 13-/22-MXS12L-10 13-/22-MXS12L-20 13-/22-MXS12L-30 13-/22-MXS12L-40 13-/22-MXS12L-50 13-/22-MXS12L-75 13-/22-MXS12L-100 142 MXS Air Slide Table 1322Dimensions / MXS16 1322Basic style Air cylinder Rotary actuator Air gripper Directional control valve Fittings & Tubing Pressure
10 5 0 15 10 5 20 25 30 0 15 10 5 20 Vertical L7 Work load [kg] Work load [kg] Work load [kg] Work load [kg] 1500 1500 1500 1500 1000 1000 1000 1000 L8 [mm] L8 [mm] L8 [mm] L8 [mm] Z 500 500 500 500 Mep m 0 0 0 0 0 2 1 3 4 5 0 15 10 5 0 15 10 5 20 0 15 10 5 20 25 30 L8 Work load [kg] Work load [kg] Work load [kg] Work load [kg] Calculation of Guide Load Factor Mounting orientation 1.
15 15 17 15 25 35 GA 15 15 15 42 51 61 111 N 4 4 4 4 6 6 6 NA 2 2 2 2 2 4 4 KA 125.5 179.5 13-/22-MXS12-10 13-/22-MXS12-20 13-/22-MXS12-30 13-/22-MXS12-40 13-/22-MXS12-50 13-/22-MXS12-75 13-/22-MXS12-100 786 MXS 1322Air Slide Table Dimensions: MXS12 1322Axial piping (12) MXS12-P 1322Maximum 6.5 Operating port 2 x M5 x 0.8 42 18.7 20 9.5 12 Other dimensions are the same as those of basic
piping on right 28 34 46 46 63 198 225 205 294 260 DBuilt-in shock absorber 39.5 CY1F 15 750 Concentrated piping on left -X 25 1200 Overall length reduced by 22% compared to Series MY2H 20Magnetically coupled rodless cylinder: Low profile guide Series CY1F: 10, 15, 25 Data 4 types of stroke adjustment are available.
length mm mm 150 200 250 300 350 400 450 500 550 600 50 100 CX 10 15 25 15 10 25 240 350 310 For 100mm stroke cylinder Series Series 10 500 CY1F CY1H CY1F CY1H MY2H Concentrated piping on right 28 34 46 46 63 198 225 205 294 260 DBuilt-in shock absorber 39.5 CY1F 15 750 Concentrated piping on left -X 25 1200 Overall length reduced by 22% compared to Series MY2H 20Magnetically coupled rodless
(1 bit) 145 20 10 85 15 10 Reading of internal parameters (7 words) 270 40 15 150 25 10 Operation mode selection 165 25 10 95 15 10 Commands for virtual I/O operation by serial communication 195 30 15 110 20 10 Reading of alarm history (4 words) 215 30 15 120 20 10 Clearing of alarm history 245 35 15 135 20 10 Confirmation of communication connection 165 25 10 95 15 10 The communication
-A1 C A3 ZS-46-E B ZS-46-B E ZS-35-B D ZS-46-D + F ZS-35-E -9No.PS-OMU0008CN-D / A ZS-46-A1 38L(2 ) C ZS-46-E 310L(2 ) ZS-46-B ZS-35-B ZS-46-D + ZS-35-E ZS-46-5F 5 2 m ZS-27-01 ZS-35-01 -10No.PS-OMU0008CN-D OUT1 LCD OUT2 () LCD 4 ON/OFF ON/OFF (kPaMPa) -11No.PS-OMU0008CN-D digit() 1digit=1kPa 1,2,3,,99,100 1kPa -0.1001.000[MPa]F.S.=1.000(-0.100)=1.100[MPa]
L 15 16 L+ L+ 16 17 L L+ 18 Notes 1.
32.5 15 4 4 4 4 9 30 163 213 52 38 17 4 6 4 5 10.5 37 179 244 65 46.5 24 5 6 4 9 12 37 194 259 75 56.5 24 5 8 4 11.5 14 46 218 300 95 72 30 5 8 4 17 15 51 233 320 114 89 32 5 1.8-15 Series CP95K Cylinder mounting accessories dimensions L, F, C and D [mm] Mounting type L STROKE STROKE Mounting type F Rear mounting STROKE Front mounting Mounting type C Mounting type D STROKE Bore 1.8-16