Yaw moment M3 = W4 x L2 YES L2 Is there any influence of noise? (Refer to Caution on Handling on pages 706 and 707.) Install a noise filter. NO M3 There is no particular problem in using the system.
The purity class of compressed air quality based on ISO8573-1:2010 2 : 6 : 3 Solid particle Moisture Oil Max number of particles per m3 Oil concentration (mg/m3) 0.1 < d 0.5 0.5 < d 1.0 1.0 < d 5.0 Pressure dew point Particle size d (m) Class Class Class (oC) at air pressure of 0.7 MPa 1 20,000 400 10 1 -70 1 0.01 2 400,000 6,000 100 2 -40 2 0.1 3 Not specified 90,000 1,000
Incremental type 14.5 mT 10.8 to 13.2 VDC (Ripple less than 1%) 40 mA 0.1 mm/pulse 0.2 mm Note) (at 20C) NPN open collector (35 VDC, 80 mA) A/B phase difference output 500 VDC, 50 M or more (between case and 12E) 33.3 Hz, 2 hours at X, Y and 4 hours at Z JIS D 1601 as standard 30 G, 3 times at X, Y, Z IP50 (IEC standard) Maximum transmission distance Position detection method Magnetic field
Incremental type 14.5 mT 10.8 to 13.2 VDC (Ripple less than 1%) 40 mA 0.1 mm/pulse 0.2 mm Note) (at 20C) NPN open collector (35 VDC, 80 mA) A/B phase difference output 500 VDC, 50 M or more (between case and 12E) 33.3 Hz, 2 hours at X, Y and 4 hours at Z JIS D 1601 as standard 30 G, 3 times at X, Y, Z IP50 (IEC standard) Maximum transmission distance Position detection method Magnetic field
JXC-OMU0026 Part A Part B Holding screw M5X14 (2) Grounding Fit the grounding cable with crimped terminal between the M3 screw and shakeproof washer as shown below and tighten the screw. M3 screw Shakeproof washer Grounding cable (with crimped terminal) Caution The cable with crimped terminal and shakeproof washer must be prepared by the user.
Part number Description Note ZS-40-A Lead wire with M8 connector Length: 3 m ZS-42-A Bracket With mounting screws for PFMC7501/7102 (M3 x 5, 2 pcs.)
, 12 VDC Note 1) Value at manifold base mounted, single operating Note 2) Withstand voltage specification of wiring unit part is equivalent to JIS C 0704 class 1.
5/32 3/8 0.04 0.12 NCRB1_W10-_S 0.55 0.20 0.35 0.02 0.20 25 0.95 1.14 0.59 0.31 0 -0.00015 (0.2) (0.26) M3 NCRB1_W10-_SE 0.33 0.37 -0.0012 -0.00045 5-40UNC 5-40UNC 0.14 10-32UNF M3 3/16 15/32 0.06 0.16 NCRB1_W15-_S 0.71 0.24 0.39 0.02 0.20 25 1.14 1.34 0.79 0.35 0 -0.00015 (0.2) (0.39) (0.24) M3 NCRB1_W15-_SE 0.43 0.39 -0.0016 -0.00045 8-32UNC 8-32UNC 0.18 10-32UNF 15/64 9/16 0.06 0.18 NCRB1
Rated voltage 5 6 24 VDC 12 VDC Refer to Table (3) shown below for availability. Refer to page 43 for ordering coil only.
Load voltage 28 VDC or less 24 VDC (10 to 28 VDC) Load current 40 mA or less 2.5 to 40 mA Internal voltage drop 0.8 V or less at 10 mA (2 V or less at 40 mA) 4 V or less Leakage current 100 A or less at 24 VDC 0.8 mA or less Indicator light Operating range Red LED lights up.
Direct installation For direct mounting, use M3 screws (2 pcs.) or equivalent. The recommended tightening torque of the screw is 0.5 to 0.7 Nm. Mount the product on a flat and even surface. Mounting on an uneven surface can damage the case. Screws and washers should be supplied by the user.
Mist generation pressure differential (MPa) IC EX: How to obtain the mist generating pressure differential if the flow rate obtaine in 1. above is 35 m3/min and the line pressure (inlet pressure P1) is 0.7 MPa: Extend horizontally from the point at which the flow rate is 35 m3/min to obtain the point that intersects with P1 = 0.7 MPa.
ABSOLUTE POSITION DETECTION SYSTEM (Continued from preceding page) 3 3 C0 Y1 X2 Resetting ABS data M3 PLS All data receptin counter ABS transfer mode Send data ready M3 ABS data 32 bits (2 bits 16 times) ABS request ON Y2 SET ABS data read Y2 X2 T204 K1 ABS data waiting timer 10ms Checksum 6 bits (2 bits 3 times) ABS request Send data ready T204 Masking ABS data 2 bits K1M10 H0003 K1X0 WANDP
(mg/m3) 0.1 d 0.5 0.5 d 1.0 1.0 d 5.0 point() 1 20,000 400 10 1 -70 1 0.01 2 400,000 6,000 100 2 -40 2 0.1 3 Not specified 90,000 1,000 3 -20 3 1 4 Not specified Not specified 10,000 4 +3 4 5 5 Not specified Not specified 100,000 5 +7 6 +10 3.3.2 Air pressure 1) Operation with a pressure exceeding the maximum operating pressure leads to breakage of the product.
LEF Auto switch model D-M9NV D-M9N D-M9B D-M9BV D-M9PV D-M9P Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular LEJ Wiring type 2-wire 3-wire NPN PNP Output type LEL Applicable load IC circuit, Relay, PLC 24 VDC relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 V) LEM Current consumption 10 mA or less Load voltage 24 VDC (10 to 28 VDC) 28
End Plate Model EX600-ED2-l EX600-ED3-l Power specifications Power connector M12 (5-pin) plug 7/8 inch (5-pin) plug Power supply (for Control/Input) 24 VDC 10%, Class 2, 2 A 24 VDC 10%, 8 A Power supply (for Output) 24 VDC +10/5%, Class 2, 2 A 24 VDC +10/5%, 8 A Enclosure IP67 (Manifold assembly) Standards CE Marking, UL (CSA), RoHS compliant Weight 170 g 175 g EX600-ED3-l EX600-ED2-l Handheld
End Plate EX600-ED2-l EX600-ED3-l Power connector Model specification M12 (5-pin) plug 7/8 inch (5-pin) plug 24 VDC 10%, Class 2, 2 A 24 VDC 10%, 8 A Power supply (for Control/Input) Power supply (for Output) 24 VDC +10/5%, Class 2, 2 A 24 VDC +10/5%, 8 A Enclosure IP67 (Manifold assembly) Standards CE marking, UL (CSA), RoHS recognition Weight 0.4 lbs (170 g) 0.4 lbs (175 g) EX600-ED3-l
Core wire colors Brown: Not connected Note 1), 24 VDC 10% (Control power supply) Note 2) White: 24 VDC +10%/5% (Solenoid valve power supply) Blue: Not connected Note 1), 0 V (Control power supply) Note 2) Black: 0 V (Solenoid valve power supply) Gray: Not connected Brown: 24 VDC +10%/5% (Solenoid valve power supply) White: 0 V (Solenoid valve power supply) Blue: 24 VDC 10% (Control power
Electrical option Piping option Port thread Special voltage Electrical entry/Electrical option Symbol Port thread Specifications Symbol Electrical entry 48 VAC 220 VAC 240 VAC 24 VAC 12 VDC 12 VDC 48 VAC 220 VAC 240 VAC 24 VAC 12 VDC 48 VAC 220 VAC 240 VAC 24 VAC 12 VDC 48 VAC 220 VAC 240 VAC 24 VAC 12 VDC 12 VDC 24 VDC 100 VAC 110 VAC 200 VAC 230 VAC 48 VAC 220 VAC 240 VAC 24 VAC 12 VDC
Note) 2 position single 1 2 Note) 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC G: Grommet C kit single only.