SMC Corporation of America
Elite Part Number Search
Search Results "S070B-VAC"

(50/60 Hz) Single phase 200 to 230 VAC (50/60 Hz) Power voltage [V] Single phase 100 to 120 VAC (50/60 Hz) Main power supply Three phase 170 to 253 VAC Single phase 170 to 253 VAC Allowable voltage range [V] Single phase 85 to 132 VAC Rated voltage [A] 3.0 5.0 2.6 1.5 0.9 Control power supply voltage [V] Single phase 200 to 230 VAC (50/60 Hz) Single phase 170 to 253 VAC 0.2 Single phase

(50/60 Hz) Single phase 200 to 230 VAC (50/60 Hz) Power voltage [V] Single phase 100 to 120 VAC (50/60 Hz) Main power supply Three phase 170 to 253 VAC Single phase 170 to 253 VAC Allowable voltage range [V] Single phase 85 to 132 VAC Rated voltage [A] 3.0 5.0 2.6 1.5 0.9 Control power supply voltage [V] Single phase 200 to 230 VAC (50/60 Hz) Single phase 170 to 253 VAC 0.2 Single phase

VAC, 50/60 Hz XLA 3 110 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz U XL XL 5 24 VDC 6 12 VDC S type: Not available for AC.

Note) 2 position single 1 2 Note) 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC G: Grommet C kit single only.

(50/60 Hz) 200 VAC 110 VAC 24 VDC 12 VDC Other LQ Valve Type (A) 2 N.C.

10%, 50/60 Hz Power supply Overcurrent protector 10 A Current consumption 3.5 A (100 VAC) to 1.5 A (240 VAC) 5.5 A (100 VAC) to 2.5 A (240 VAC) Alarm Refer to alarm function.

Transformer unnecessary Power supply Applicable to 200 to 230 VAC, or 380 to 415 VAC Transformers are unnecessary even when used overseas.

D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).

temperature 40C (200 VAC) Set temperature range 10 to 30C Temperature stability 2.0C 615 Maintenance free Magnet pump Low-noise design 55 dB (A) Power supply 100/200 VAC 50/60 Hz 230 VAC 50/60 Hz 191 Thermo-chiller Basic Type HRSE Series Circulating Fluid Temperature Controller Simple function and performance Cooling capacity 1.2, 1.6, 2.2 kW (60 Hz) Power supply 100/200 VAC (50/60 Hz) 230

Electrical entry P/E port R port 24 V, 12 V, 6 V, 5 V, 3 VDC/100 V, 110 V, 200 V, 220 VAC AC specifications (50/60 Hz) Grommet L plug connector M plug connector 100 VAC 200 VAC 1 2 3 4 110 VAC [115 VAC] 220 VAC [230 VAC] MN: Without lead wire G: Lead wire length: 300 mm L: With lead wire (Wire length: 300 mm) M: With lead wire (Wire length: 300 mm) 200 VAC, 220 VAC specifications An AC specification

D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).

D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).

D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).

D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).

D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).

Seal Metal seal Rubber seal Coil voltage 0 1 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Function 1 2 3 Stations U side Standard type (1 W) Low wattage type (0.5 W) External pilot Nil Y R (1) D side (2) Note 1) Applicable to DC specifications. Note 2) Refer to page 2-5-39 for external pilot specification.

, 110 VAC, 200 VAC, 220 VAC (50/60 Hz) Coil rated voltage 10% of rated voltage Allowable voltage fluctuation 2 position double (Rubber) 3 position closed center Class B or equivalent Coil insulation type (A) 4 (B) 2 (A) 4 (B) 2 1 W DC (42 mA) 24 VDC 1 W DC (83 mA) 12 VDC Power consumption (Current) Inrush 1.2 VA (12 mA), Holding 1.2 VA (12 mA) 100 VAC 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2