UR Edition C Safety Instructions Be sure to read the Handling Precautions for SMC Products (M-E03-3) and Operation Manual before use.
C11.2 1218 MY1H Series Mechanically Jointed Rodless Cylinder Linear Guide Type Side Support Side support A MY-SA 2 x G F 2 x H E C D A B Side support B MY-SB MY1B 2 x J MY1H MY1H MY1B E A B C D MY1M MY1C (mm) MY1H Part no.
Indicate the option symbols according to the priority order of D,C,S. Note 2) For details of the lever detection switch alone, refer to page 595. Transfer direction Transfer direction P R Applicable Auto Switches/Refer to pages 941 to 1067 for further information on auto switches.
D A B Side support B MY-SB 2 x J MY1B MY1B MY1H E A B MY1B C D MY1M (mm) MY1C A 61 70 87 B C D E F G H J Part no.
M9N M9NV 3-wire (NPN) IC circuit 5 V, 12 V M9P M9PV 3-wire (PNP) M9B M9BV 2-wire 12 V 24 V Relay PLC Yes Grommet F9NW F9NWV 3-wire (NPN) 5 V, 12 V IC circuit Diagnostic indication (2-color indication) F9PW F9PWV 3-wire (PNP) F9BW F9BWV 2-wire Lead wire length symbols: 0.5 m Nil (Example) M9N 3 m L (Example) M9NL 5 m Z (Example) M9NZ 12 V Solid state switches marked are produced
Variation: A (Normally Closed, Bellows Seal), Flange Size: 40, Indicator, Actuator Port Direction: A (w/Indicator, Actuator Port Direction on Flange Side), Temperature Specifications, Heater: 5 to 60°C, w/o Heater, Auto Switch: M9B (M9B--Solid State, Gen.
AC Lead wire length (m) Load voltage DC Auto switch model Special function Electrical entry Indicator light Wiring (Output) Pre-wired connector Applicable load Type In-line Perpendicular 0.5 (Nil) 1 (M) 3 (L) 5 (Z) M9NV M9PV M9BV M9NWV M9PWV M9BWV M9NAV M9PAV M9BAV M9N M9P M9B M9NW M9PW M9BW M9NA M9PA M9BA 5 V, 12 V 3-wire (NPN) 3-wire (PNP) IC circuit Solid state switch 12 V 2-wire 3-wire
Fittings & Tubing Air Cylinders Rotary Actuators Side tapped mounting [1/N1] Through-holes in open/close direction [2/N2] 4 x MM through Thread for mounting attachment C C B A 4 x H through Hole for mounting attachment S S O O B A (mm) (mm) MM M2.5 x 0.45 M3 x 0.5 M4 x 0.7 M5 x 0.8 C 2 2.5 4 5 H 2.9 3.4 4.5 5.5 B 5.7 7 9 12 B 5.7 7 9 12 Model A 3 4 5 6 Model A 3 4 5 6 11221122112211221 N1
C dimension (Body length): 84 mm Example MGPW MGPW MGQ Theoretical Output MGG OUT IN Made to Order: Individual Specifications (For details, refer to page 517.)
Operating equipment: MHC2-6D A part a b c d e f = 20 (mm) = 3 (mm) = 4 (mm) = 4 (mm) = 5 (mm) = 6 (mm) b c a e B part f d z f1 x.Calculate the inertial moment of the attachment. Assuming the attachment material is aluminium alloy (relative density=2.7), r1= 16.4 (mm).
Operating equipment: MHC2-6D A part a b c d e f = 20 (mm) = 3 (mm) = 4 (mm) = 4 (mm) = 5 (mm) = 6 (mm) b c a Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com e B part f d z f1 x.Calculate the inertial moment of the attachment.
How to Order B 32 30 D C CQ2Y Standard B F9BW S 32 30 D C CDQ2Y With auto switch Number of auto switches With auto switch (Built-in magnet) 2 pcs. 1 pc. n pcs.
Align the surface C (on the side with round mounting holes) of the end cover of the replacement actuator and surface D of the stepped part on the guide. 4) In the condition described in (3), put surface A and surface B in close contact with each other. Tighten the 4 cylinder fixing bolts evenly. 1. The shock absorber of series CY1F can be replaced.
Align the surface C (on the side with round mounting holes) of the end cover of the replacement actuator and surface D of the stepped part on the guide. 4) In the condition described in (3), put surface A and surface B in close contact with each other. Tighten the 4 cylinder fixing bolts evenly. 1. The shock absorber of series CY1F can be replaced.
Extend upward from 300 mm/s on the horizontal axis of the graph to the intersection point with the line for a tube bore size of 50 mm, and then extend leftward from this point to find the load of 40 kg. 4 JMB Series Dimensions Basic: JMDBB MM Width across flats KA 2 x P (Rc, NPT, G) 4 x J G G D E B C H1 AL A N F H ZZ + Stroke S + Stroke N M K B C B1 Dimensions [mm] Bore size Stroke range
Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.
H:Distance from the cylinder center axis to the mounting surface for the table L MXY H dimension (mm) MXH6 MXH10 MXH16 MXH20 MTS 24.5 30.5 34.5 41.5 Cylinder shaft center m Load center of gravity Selection Graph z to c (Vertical Mounting) Graph c c Maximum Speed 500 mm/s or Less Graph z z Maximum Speed 100 mm/s or Less 1 100 10 Mass m (kg) Mass m (kg) 20 0.1 16 20 16 1 10 10 6 6 0.01 0.1
Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com c B part e f d 2.
Align the surface C (on the side with round mounting holes) of the end cover of the replacement actuator and surface D of the stepped part on the guide. 4) In the condition described in (3), put surface A and surface B in close contact with each other. Tighten the 4 cylinder fixing bolts evenly. Bore size (mm) 10 15 25 No. RB0805-X552 RB1006-X552 2.
9 High frequency quenching, Hard chrome plated Guide rod r CXTL Bearing steel Collar Aluminum alloy Clear anodized @0 Piston Aluminum alloy Chromated @1 Bearing alloy, Carbon steel Stainless steel 12 to 25 Slide bearing t Hard chromium electroplated Piston rod @2 y Ball bushing Carbon steel 32, 40 Nickel plated Carbon tool steel u C set ring Phosphate coated Type C snap ring Nickel plated