For futhr details ol accessorbs. reler lo 'accessorles' on page 6. 4 rP300 METHOD OF OPERATION Signal pressure from a controlled pressure source enters the 1P300 input chamber and exerts a force on the diaphragms. A pressure differential between the two diaphragms creates a force to open the pilot valve.
For futhr details ol accessorbs. reler lo 'accessorles' on page 6. 4 rP300 METHOD OF OPERATION Signal pressure from a controlled pressure source enters the 1P300 input chamber and exerts a force on the diaphragms. A pressure differential between the two diaphragms creates a force to open the pilot valve.
PF-OMK0003CN-E PFMV5 PFMV5 + L (ZS-36-A) 10n +24(n=15) 10n +14 L L L -22No.
Valve: None; Stop Valve: None, Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
, Bracket: None, Calibration Certificate: A (w/Calibration Certificate)
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 03 (3/8), Output Specification/Temperature Sensor: KT (OUT1: Analogue 4 to 20 mA - OUT2: Analogue 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 03 (3/8), Output Specification/Temperature Sensor: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature:
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature
Flow Switch Type: 5 (Remote Sensor Unit), Rated Flow Range: 20 (2~16L/min), Return Unit: S (Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Flow Switch Output: 2T (Remote Sensor Unit; Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None, Temp. Analog 4 to 20 mA; Temperature Sensor: Yes)
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes)
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector)
Valve: None; Stop Valve: None, Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal;
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m)