SMC Corporation of America
Elite Part Number Search
Search Results "NCY2S25H-5000"

M8 connector 50 Series SYJ7000 How to Order Connector Assembly for L and M Plug Connector How to Order M8 Connector Cable : SY100-30-4AFor DC V100-49-1: SY100-30-1AFor 100 VAC : SY100-30-2ACable length For 200 VAC 300 mm 1 : SY100-30-3AFor other voltages of AC 500 mm 2 1000 mm 3 2000 mm : SY100-30-A 4 Without lead wire 5000 mm 7 (with connector and 2 of sockets only) Lead wire length Nil

V100-49-15 D V115 Light/surge voltage suppressor Rated voltage Nil Without light/surge voltage suppressor With surge voltage suppressor (Non-polar type) With light/surge voltage suppressor (Non-polar type) S Z 5 24 VDC 6 12 VDC Cable length 1 100 VAC 50/60 Hz 1 2 3 4 7 300 mm 500 mm 1000 mm 2000 mm 5000 mm 2 200 VAC 50/60 Hz DOZ is not available.

P1 = 0.1MPa 0.04 0.04 0.02 0.02 Selection 0 0 15000 10 5000 Warning 1. Do not introduce air from the outlet side as this can damage the damper. Caution 1.

Series LC1 controller (vertical specification) Description Part no. 57026-5000 (for UL1007) 57027-5000 (for UL1015) Crimping tool 57031-6000 Puller 201 Series LC7R Regenerative Absorption Unit Selection Guide The graphs show the relationship between speed and distance where the use of a regenerative absorption unit becomes necessary for each vertical specification actuator based on the desired

Description 57026-5000 (for UL1007) 57027-5000 (for UL1015) Crimping tool Puller 57031-6000 307 Series LC6D Connection Examples Wiring numbers Electrical wires 0.5mm or larger (AWG18 to 20) 0.2mm or larger (shielding wire) (AWG18 to 24) For open collector output Series LC6D + 5VDC CW input 330 7 3 +24V + Receptacle side (female terminal insertion side) 24VDC CW 10 6 GND 330 2 CCW input

Maximum dead weight deflection (mm) REA40 REA25 REA50 REA63 Note:1MPa = 145psi 1kg = 2.2046lb 1in = 25.4mm 0 1000 2000 3000 4000 5000 Stroke (mm) The above deflection data indicate values for external movement within the stroke. Max. Connection Fitting Weight The REA (basic type) is not directly connected to the load, and is guided by another shaft (LM guide, etc.).

VDC Pressure Characteristics Pressure Characteristics 1 i 6 _ 102 9 s 3 o t 5 o 1000 2000 3000 4000 5000 F ow rale f/min(ANBI 20 30 40 200 400 600 400 looo Fow rale i/m n(ANF) 1 3 1 102 e7 T3 d 7 3 58 a a a 29 1 5 1 5 o 4 8 1 2 1 6 2 A 2 4 2 8 400 800 1200 1.in 2004 2400 200 400 600 800 1000 Belief flo\i/ i.

S Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R Lead wire length U 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.

1.680 kPa 0 to 1,600.0 -105 to 1680 Kgf/cm2 0 to 16.315 -1.07 to 17.13 ISE71 Bar 0 to 16.000 -1.05 to 16.80 Psi 0 to 232.06 -15.2 to 243.7 Pressure gauge measurement value (PD) 1000 to 5000 738 to 5200 : The figure below describes the relationship between the pressure gauge measurement value (PD) and pressure value in the unit specification (MPa) of the ISE70 series.

Number of displays 3-screen display (Main display, sub display x 2) Display Display color 1) Main display: Red/Green 2) Sub display: Orange Number of display digits Main display: 4 digits (7-segments) Sub display: 4 digits (Upper 1 digit 11-segments, 7-segments for other) Operation light LED is ON when switch output is ON (OUT1, OUT2: Orange) Digital filter 4 0, 10, 50, 100, 500, 1000, 5000

/ TEMP OUTHI ALARM PUMPF COMM TIME EXT OFSET Output setting of circulating fluid temperature range rising alarm / / / Temp when only pump rus when alarm is generated FILTT FLTR TIME ON 0 PUMPF 350 Unused / DI filter maintenance time*2 TEMP OUTHI OUTP PUMP TIME EXT HITEMP LIMIT 5000 / / Time when only pump rus when alarm is generated / Switching circulating fluid temperature drop

Number of displays 3-screen display (Main display, sub display x 2) Display Display color 1) Main display: Red/Green 2) Sub display: Orange Number of display digits Main display: 4 digits (7-segments) Sub display: 4 digits (Upper 1 digit 11-segments, 7-segments for other) Operation light LED is ON when switch output is ON (OUT1, OUT2: Orange) Digital filter 4 0, 10, 50, 100, 500, 1000, 5000

. -63No.PS-OMV0006-D Unit specification and pressure gauge measurement value (PD) Series Unit Rated pressure range Display/settable range MPa -0.100 to 1.0 -0.105 to 1.050 kPa -100 to 1000.0 -105 to 1050 kgf/cm2 -1.02 to 10.197 -1.07 to 10.71 ISE20B bar -1.00 to 10.000 -1.05 to 10.50 psi -14.5 to 145.04 -15.2 to 152.3 Pressure gauge measurement value (PD) 600 to 5000 580 to 5200 MPa 0 to

Number of displays 3-screen display (Main display, sub display x 2) Display Display color 1) Main display: Red/Green 2) Sub display: Orange Number of display digits Main display: 4 digits (7-segments) Sub display: 4 digits (Upper 1 digit 11-segments, 7-segments for other) Operation light LED is ON when switch output is ON (OUT1, OUT2: Orange) Digital filter 4 0, 10, 50, 100, 500, 1000, 5000

type LCD Number of displays 3-screen display (Main display, sub display x 2) Display Display color 1) Main display: Red/Green 2) Sub display: Orange Number of display digits Main display: 4 digit (7-segments) Sub display: 4 digit (Upper 1 digit 11-segments, 7-segments for other) Operation light LED is ON when switch output is ON (OUT1: Orange) Digital filter 4 0, 10, 50, 100, 500, 1000, 5000

Flow Rate Characteristics Relief Characteristics IR3020-04-A Supply pressure: 0.7 MPa IR3020-04-A Back pressure: 0.7 MPa 0.7 0.7 0.6 0.6 Set pressure [MPa] Set pressure [MPa] 0.5 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 0 1000 2000 3000 4000 5000 6000 0 0 1000 2000 3000 4000 5000 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Pressure Characteristics Supply pressure: 0.3 to 1.0 MPa Set pressure

38.5 Lead wire with connector ISA-8-A Brown White 15 Blue Black 5000 23.5 Brown Lead wire with connector ISA-8-B White Blue Black 30.8 15 876 A Air Catch Sensor Series ISA2 Bracket Mounting Position With 2 stations, the bracket is mounted on the second sensor from the left.

.: ZS-31-B) 5000 (38.6) Brown 45 2: White 1: Brown 30 White 15 Blue 4: Black 3: Blue Black M12 (Part no.: ZS-31-C) (31) 5000 Brown 45 23.5 When used as a switch output device 30 White No. Description Lead wire color Note 1 DC(+) Brown 12 to 24 VDC Blue (30.8) 2 OUT2 White Switch output 2 24.55 Black 3 DC() Blue 0 V 4 OUT1 Black Switch output 1 When used as an IO-Link device 15 No.

47.5 59 71.5 83 7 7 8 9 13 15 18 24 38 42 3 4.5 5 6 8.5 10 16 21 18 20 0.5 0.7 0.8 1 1.25 1.5 2 2.5 2.5 3 4 6 6.5 8 11 13 20 26 22 26 16 16 21 24 31 41 50 59.5 79 96 2 2 4.5 5 6 7.5 9.5 11.5 14 16 0.02 0.02 0.04 0.07 0.15 0.29 0.56 1.04 2.6 4.5 6 6 7 8 11 14 19 24 30 36 5 5 7 8 11 13.5 16 20 22 24 10 10 13 17 22 27 32 41 46 55 0.5 0.5 0.5 0.5 0.75 1 1.25 2 2.5 3 112 200 300 500 1300 3100 5000

Manual Override DXT1215T 5W U 01 (-X1) Warning Cable length [mm] Symbol Cable length [mm] 1 300 2 500 3 1000 4 2000 5 3000 6 4000 7 5000 The manual override is used for switching the main valve regardless of the valves electric signal. As the connected actuator will start operating due to this manual operation, be sure to confirm that it is safe to do so beforehand.