SMC Corporation of America
Elite Part Number Search
Search Results "LEFSH40S4B-600-R2A21"

With Rod Boot Bore size (mm) e f h ZZ Stroke range (mm) l 40 50 63 80 100 20 to 500 43 11.2 59 1/4 stroke 154 20 to 600 52 11.2 66 1/4 stroke 167 20 to 600 52 11.2 66 1/4 stroke 178 Dimensions of the mounting brackets are the same as those of the standard double acting single rod type.

m(kg) Load weight: m(kg) 160 600 600 140 500 500 125 400 400 300 300 200 200 100 100 100 500 400 300 200 100 500 400 300 200 Maximum speed: V(mm/s) Maximum speed: V(mm/s) 31

200 100 100 500 400 300 200 100 Maximum speed: V(mm/s) Maximum speed: V(mm/s) Graph 6 Graph 3 0.4MPaP<0.5MPa 0.4MPaP<0.5MPa 3000 3000 2000 2000 160 140 1000 1000 700 800 900 700 800 900 125 Load weight: m(kg) Load weight: m(kg) 600 600 160 500 500 400 400 140 320 125 300 300 200 200 280 100 100 100 500 400 300 200 100 500 400 300 200 Maximum speed: V(mm/s) Maximum speed: V(mm/s) Graph 7

, 800 25 1200 25 200, 300, 400, 500, 600, 800, 1000 2 axes 1500 32 Note 1) Strokes exceeding the standard strokes are available as a special order.

Distance from the ionizer to the neutralized workpiece (mm) IZS40/41 IZS42 With air purge With air purge Ion generation frequency (Hz) Without air purge Without air purge High speed static neutralization cartridge 0.1 100 to 175 50 to 1300 50 to 2000 50 to 2000 0.5 100 to 175 50 to 1300 50 to 2000 50 to 2000 1 300 to 500 300 to 1500 400 to 2000 600 to 2000 100 to 175 50 to 1300 50 to 2000

1000 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 1000 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 1000 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 1000 Unit: MPa Bore size (mm) 32 40 50 63 80 100 Min. operating pressure 0.02 0.01 Note 1) Intermediate strokes not listed above are

Bar length (mm) IZN10-G-100-X216 IZN10-G-200-X216 IZN10-G-300-X216 IZN10-G-400-X216 IZN10-G-500-X216 IZN10-G-600-X216 100 Part no. IZN10-G-X198 Part no.

Bar length [mm] IZN10-G-100-X226 100 IZN10-G-200-X226 200 IZN10-G-300-X226 300 IZN10-G-400-X226 400 IZN10-G-500-X226 500 IZN10-G-600-X226 600 Part no.

Description Material Note ALF400, 400-06 ALF500, 600 ALF800, 900 Platinum silver painted Body Housing Aluminum die-casted Aluminum casted Aluminum die-casted 1 2 Platinum silver painted Replacement Parts No. Description Material Part no. Qty.

When P2 + 0.1 b, choked flow P1 + 0.1 293 Q = 600 x C (P1 + 0.1) (1) 273 + T When P2 + 0.1 > b, subsonic flow P1 + 0.1 VXH VXF VX3 VXA 2 P2 + 0.1 b P1 + 0.1 Q = 600 x C (P1 + 0.1) 1 (2) 1 b 293 273 + T 157 VXD Series Q : Air flow rate [L/min (ANR)] C : Sonic conductance [dm3/(sbar)], dm3 (Cubic decimeter) of SI = L (liter). b : Critical pressure ratio [] P1 : Upstream pressure [MPa

VV5Z5-20 VV5Z5-21 Gasket Dust cap Caution Mounting Screw Tightening Torques M3: 0.8 Nm Applicable base VV5Z5-21P 3-3-62 5 Port Solenoid Valve Body Ported Series VZ5000 Type 20 Manifold VV5Z5-20Station 1 (4(A), 2(B) port) 2n-Rc 1/8 Grommet (G), (H) (Pitch) 4-4.5 (Mounting hole) VK VZ VF VFR 6-Rc 1/8 (1(P), 3/5(R) port) PE port (Pilot EXH) VP4 VZS Manual override (Non-locking) G: 300 mm H: 600

for 16, 20) Data MY2H/HT 16, 25, 40 50 to 600 601 to 1500 (Up to 1000 for 16) 10 10 to 75 80, 90, 100, 110, 120, 125, 150 CXSM CXSL 10 to 100 15 110, 120, 125, 150 110, 120, 125, 150, 175, 200 20, 25, 32 10 to 100 225, 250, 275, 300 (CXWM16 to 25) 225, 250 (CXWM32) 225, 250, 275 (CXWL16 to 25) 225 (CXWL32) CXWM 16, 20, 25, 32 25 to 200 CXWL 16, 20, 25, 32 225, 250, 275 25 to 200 ML1 25,

Refer to graph (16) based on horizontal mounting, the maximum speed of 600 mm/s, and 125 stroke.

outputs) type Maximum load current: 80 mA Internal voltage drop: 1.5 V or less PF2MC7###-##-E#-### PNP (1 output) + Analogue (1 to 5 V) output type PF2MC7###-##-F#-### PNP (1 output) + Analogue (4 to 20 mA) output type Maximum load current: 80 mA Internal voltage drop: 1.5 V or less E: Analogue output: 1 to 5 V Output impedance: 1 k F: Analogue output: 4 to 20 mA Maximum load impedance: 600

L3: Analogue output: 1 to 5 V or 0 to 10 V Output impedance: 1 k L4: Analogue output: 4 to 20 mA Max. load impedance: 600 Min. load impedance: 50 PNP + Analogue output type PF3A7##H-L3/L4#-##-# Maximum load current: 80 mA Internal voltage drop 1.5 V max.

Hysteresis 4 Variable Protection Short circuit protection Voltage input: 1 to 5 VDC, 0 to 10 VDC (only when the power supply voltage is 24 VDC) 6 Output type Current input: 4 to 20 mA Analogue output 5 (0 L/min to max. value of the rated flow) Impedance Voltage output Output impedance approx.: 1 k Current output Max. load impedance: 300 at 12 VDC, 600 at 24 VDC Response time 2 50 ms or

Status (3): No alarm is activated since the temperature returns to the range within Out Time 600 seconds even though it is below 18C, which is the value set for AL11. Status (4): No alarm is activated since the temperature returns to the range within Out Time 600 seconds even though it is above 22C, which is the value set for AL10.

Status (3): No alarm is activated since the temperature returns to the range within Out Time 600 seconds even though it is below 18C, which is the value set for AL11. Status (4): No alarm is activated since the temperature returns to the range within Out Time 600 seconds even though it is above 22C, which is the value set for AL10.

Status (3): No alarm is activated since the temperature returns to the range within Out Time 600 seconds even though it is below 18C, which is the value set for AL11. Status (4): No alarm is activated since the temperature returns to the range within Out Time 600 seconds even though it is above 22C, which is the value set for AL10.

Status (3): No alarm is activated since the temperature returns to the range within Out Time 600 seconds even though it is below 18C, which is the value set for AL11. Status (4): No alarm is activated since the temperature returns to the range within Out Time 600 seconds even though it is above 22C, which is the value set for AL10.