The maximum dischargeable drainage rate is 400 cc/min.
Bore size Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CS1 Pressure 0.5 MPa Load factor 50% Cylinder stroke 1000 mm 50 63 80 100 125 140 160 180 200 250 300 Average speed (mm/s) Series 1000 1100 Perpendicular, upward actuation 900 Horizontal actuation 800 700 600 500 400 300 200 100 VK VQ7-8-FG-S-A03 VQ7-8-FG-S-RA03 VZ VF 0 1000 1100 VFR 900 800 700 600 500 400 300 200
RSH20, 32 Graph q Graph w Bore size 50, 63, 80/ = 0 Bore size 50, 63, 80/ = 0.1 1.0 RSH20 RSH32 0.9 Operating pressure ZP [MPa] 0.8 1300 1300 80 0.7 1200 1200 RSQ 0.6 1100 1100 0.5 RSG 1000 1000 0.4 900 900 0.3 RS 63 80 Load mass m [kg] Load mass m [kg] 0.2 800 800 50 0.1 MI 700 700 500 0 100 200 300 400 600 600 63 Lateral load F [N] 500 500 50 400 400 RS1H50, 63, 80 300 300 1.0 RS1H80 RS1H50
The highest value in the past 15 seconds is displayed relative to the rated torque of 100%. 0 to 400 % 14 Instantaneous torque Torque that occurred instantaneously is displayed. The value of the torque that occurred is displayed in real time relative to the rated torque of 100%. 0 to 400 % 15 Within one-revolution position Position within one-revolution is displayed in encoder pulses.
(LAT3-10: 5.0, LAT3-20: 4.8, LAT3-30: 3.9, LAT3-50: 2.0) Note 4: If the target position exceeds the stroke range, the Card Motor operation speed is set to above 400 mm/s or any other impossible value is set, Step Data error will be generated from the Card Motor controller during the Step Data operation.
rate: 50% Stroke 500 mm Series CM2 Pressure 0.5 MPa Load rate: 50% Stroke 300 mm Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation SY3140-01 Horizontal actuation 800 700 600 500 400 300 200 100 0 SY5140-02 800 700 600 500 400 300 200 100 0 SY7140-03 800 700 600 500 400 300 200 100 0 SY9140-04 Cylinder is in extending.
However, for 400 VAC, model should also be selected based on the amount of processed air of 380 VAC regarding IDFA100F to 150F. (Correction factor is based on the rated conditions of 380 VAC, so when the factor of rated conditions of 400 VAC is inputted , the amount of processed air of 400 VAC can be found.)
" SO, "63 a.5 25, 50, 75, 100,125, 150, 175, 200, 250.300, 350. 400. 450, 500 40 " !
North America For Europe For France Special Maximum clamping force (lbf) Maximum clamping force (N) 8000 2000 7000 6000 1500 80 80 5000 4000 1000 63 63 3000 40 50 2000 500 50 1000 40 0 0 5 10 15 20 0 450 400 350 300 250 200 150 100 50 0 Arm length L (mm) Arm length L (in) Allowable load for clamp arm end Refer to the graph on pages 190 and 191 for parts weight of the arm.
Stroke length tolerance 10-/11-: 30 to 400 mm/s, 21-/22-: 50 to 400 mm/s Piston speed +1.4 0 Mounting Basic/Axial foot/Flange 10-/11-: Fluorine grease 21-/22-: Lithium soap based grease 10-: Class 4, 21-: Class 5 11-/22-: Class 3 Grease Refer to page 889 for the applicable auto switch list.
350, 400, 450, 500, 600, 700, 800 1300 12-CY3R40 40 Rc1/4 NPT1/4 G1/4 12-CY3R50 12-CY3R63 50 63 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 Note 1) Stroke exceeding the standard stroke but below the maximum manufacturable stroke is available as special order.
, 500 15 750 1 axis Operating pressure (MPa) Piston area (mm2) 100, 200, 300, 400, 500, 600 20 Bore size (mm) 1000 0.3 0.2 0.4 0.5 0.6 0.7 100, 200, 300, 400, 500, 600, 800 25 1200 10 15 23 78 31 39 54 46 100, 200, 300, 400, 500, 600, 800, 1000 25 2 axis 15 35 52 176 70 88 123 105 1500 32 20 62 94 314 125 157 219 188 Note) Strokes are manufacturable in 1 mm increments up to the maximum strokes
Flow-rate Characteristics Note) Values when the main valve is fully open Male thread nozzle High efficiency nozzle 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 400 VMG1-R02-400:4 KNH-R02-200 VMG1-R02-350:3.5 350 VMG1-R02-300:3 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 300 KN-R02-250:2.5 KN-R02-200:2 250 KN-R02-150:1.5 KNH-R02-150 200 KN-R02-100:1 150 KNH-R02-100
400 300 200 100 0 VQ2101 Port size: 8 One-touch fitting It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open.
flow rate, (4) Power supply: 400 VAC 5: (1) Ambient temperature: 32 oC, (2) Circulating fluid: Clean water, (3) Circulating fluid temperature: 20 oC, (4) Load: Refer to the specified cooling capacity (5) Circulating fluid flow rate: Rated flow rate, (6) Power supply: 400 VAC, (7) Piping length: Minimum 6: With pressure control function using an inverter.
, (5) Circulating fluid flow rate: Rated flow rate, (6) Power supply: 400 VAC, (7) Piping length: Minimum 5 With the pressure control mode that controls the pressure automatically with the inverter.If the pressure control mode is not necessary,use the flow control function or the pump output setting function. 6 Required flow rate to maintain the cooling capacity.
Ambient temp. 500 Heating capacity [W] Heating capacity [W] 400 40 40 400 32 32 300 300 25 25 5 5 200 200 100 100 0 0 10 15 20 25 30 35 40 10 15 20 25 30 35 40 Circulating fluid temperature [] Circulating fluid temperature [] 50Hz 60Hz Fig 9-11 Heating capacity (HRR010-A-20-) 9.5.4 HRR010-W-20400 400 Facility water temp.
Key lock relese, DS unlock Key lock relese, DS lock Key lock, DS unlock Key lock, DS lock Key lock relese, DS unlock Common Device access locks Operation pressure Sets the pressure in the operation mode. 0 to 1050 kPa 400 kPa Common Sets the pressure in the standby mode.
8 to 500 30 to 1200 20 to 1000 10 to 500 401 to 500 20 to 1100 12 to 750 6 to 400 24 to 1300 16 to 950 8 to 500 30 to 1200 20 to 1000 10 to 500 501 to 600 20 to 900 20 to 540 20 to 270 24 to 1200 16 to 800 8 to 400 30 to 1200 20 to 1000 10 to 500 601 to 700 20 to 630 20 to 420 20 to 230 24 to 930 16 to 620 8 to 310 30 to 1200 20 to 900 10 to 440 Speed [mm/s] Stroke 701 to 800 20 to 550 20
USB 7. 106 No.SFOD-OMT0009CN-B 7. 7. 4. ( EMG ) 4. 107 No.SFOD-OMT0009CN-B 1. 1.1 LEY/LEYG LEY16/LEYG16 LEY25/LEYG25 LEY32/LEYG32 LEY40/LEYG40 A B C A B C A B C A B C [mm] 10 5 2.5 12 6 3 16 8 4 16 8 4 [mm] 300 300 300 400 400 400 500 500 500 500 500 500 [mm/s] 500 250 125 500 250 125 500 250 125 300 150 75 [mm/s] 15 8 4 18 9 5 24 12 6 24 12 6 () [mm/s] 22 12 6 26 13 7 34 17 9 34